Test–retest reproducibility of human brain multi‐slice 1H FID‐MRSI data at 9.4T after optimization of lipid regularization, macromolecular model, and spline baseline stiffness. Issue 1 (21st September 2022)
- Record Type:
- Journal Article
- Title:
- Test–retest reproducibility of human brain multi‐slice 1H FID‐MRSI data at 9.4T after optimization of lipid regularization, macromolecular model, and spline baseline stiffness. Issue 1 (21st September 2022)
- Main Title:
- Test–retest reproducibility of human brain multi‐slice 1H FID‐MRSI data at 9.4T after optimization of lipid regularization, macromolecular model, and spline baseline stiffness
- Authors:
- Ziegs, Theresia
Wright, Andrew Martin
Henning, Anke - Abstract:
- Abstract : Purpose: This study analyzes the effects of retrospective lipid suppression, a simulated macromolecular prior knowledge and different spline baseline stiffness values on 9.4T multi‐slice proton FID‐MRSI data spanning the whole cerebrum of human brain and the reproducibility of respective metabolite ratio to total creatine (/tCr) maps for 10 brain metabolites. Methods: Measurements were performed twice on 5 volunteers using a short TR and TE FID MRSI 2D sequence at 9.4T. The effects of retrospective lipid L2‐regularization, macromolecular spectrum and different LCModel baseline flexibilities on SNR, FWHM, fitting residual, Cramér‐Rao lower bound, and metabolite ratio maps were investigated. Intra‐subject, inter‐session coefficient of variation and the test–retest reproducibility of the mean metabolite ratios (/tCr) of each slice was calculated. Results: Transversal, sagittal, and coronal slices of many metabolite ratio maps correspond to the anatomically expected concentration relations in gray and white matter for the majority of the cerebrum when using a flexible baseline in LCModel fit. Results from the second measurements of the same subjects show that slice positioning and data quality correlate significantly to the first measurement. L2‐regularization provided effective suppression of lipid‐artifacts, but should be avoided if no artifacts are detected. Conclusion: Reproducible concentration ratio maps (/tCr) for 4 metabolites (total choline,Abstract : Purpose: This study analyzes the effects of retrospective lipid suppression, a simulated macromolecular prior knowledge and different spline baseline stiffness values on 9.4T multi‐slice proton FID‐MRSI data spanning the whole cerebrum of human brain and the reproducibility of respective metabolite ratio to total creatine (/tCr) maps for 10 brain metabolites. Methods: Measurements were performed twice on 5 volunteers using a short TR and TE FID MRSI 2D sequence at 9.4T. The effects of retrospective lipid L2‐regularization, macromolecular spectrum and different LCModel baseline flexibilities on SNR, FWHM, fitting residual, Cramér‐Rao lower bound, and metabolite ratio maps were investigated. Intra‐subject, inter‐session coefficient of variation and the test–retest reproducibility of the mean metabolite ratios (/tCr) of each slice was calculated. Results: Transversal, sagittal, and coronal slices of many metabolite ratio maps correspond to the anatomically expected concentration relations in gray and white matter for the majority of the cerebrum when using a flexible baseline in LCModel fit. Results from the second measurements of the same subjects show that slice positioning and data quality correlate significantly to the first measurement. L2‐regularization provided effective suppression of lipid‐artifacts, but should be avoided if no artifacts are detected. Conclusion: Reproducible concentration ratio maps (/tCr) for 4 metabolites (total choline, N‐acetylaspartate, glutamate, and myoinositol) spanning the majority of the cerebrum and 6 metabolites (N‐acetylaspartylglutamate, γ‐aminobutyric acid, glutathione, taurine, glutamine, and aspartate) covering 32 mm in the upper part of the brain were acquired at 9.4T using multi‐slice FID MRSI with retrospective lipid suppression, a macromolecular spectrum and a flexible LCModel baseline. … (more)
- Is Part Of:
- Magnetic resonance in medicine. Volume 89:Issue 1(2023)
- Journal:
- Magnetic resonance in medicine
- Issue:
- Volume 89:Issue 1(2023)
- Issue Display:
- Volume 89, Issue 1 (2023)
- Year:
- 2023
- Volume:
- 89
- Issue:
- 1
- Issue Sort Value:
- 2023-0089-0001-0000
- Page Start:
- 11
- Page End:
- 28
- Publication Date:
- 2022-09-21
- Subjects:
- human brain -- lipid regularization -- magnetic resonance imaging -- ultra‐high field strengths -- whole‐brain MRSI
Nuclear magnetic resonance -- Periodicals
Electron paramagnetic resonance -- Periodicals
616.07548 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)1522-2594 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/mrm.29423 ↗
- Languages:
- English
- ISSNs:
- 0740-3194
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5337.798000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 24233.xml