Clinically compatible subject‐specific dynamic parallel transmit pulse design for homogeneous fat saturation and water‐excitation at 7T: Proof‐of‐concept for CEST MRI of the brain. Issue 1 (21st September 2022)
- Record Type:
- Journal Article
- Title:
- Clinically compatible subject‐specific dynamic parallel transmit pulse design for homogeneous fat saturation and water‐excitation at 7T: Proof‐of‐concept for CEST MRI of the brain. Issue 1 (21st September 2022)
- Main Title:
- Clinically compatible subject‐specific dynamic parallel transmit pulse design for homogeneous fat saturation and water‐excitation at 7T: Proof‐of‐concept for CEST MRI of the brain
- Authors:
- Lévy, Simon
Herrler, Jürgen
Liebert, Andrzej
Tkotz, Katharina
Fabian, Moritz S.
Eisen, Christian
Grodzki, David
Uder, Michael
Dörfler, Arnd
Zaiss, Moritz
Nagel, Armin M. - Abstract:
- Abstract : Purpose: To evaluate the benefits and challenges of dynamic parallel transmit (pTx) pulses for fat saturation (FS) and water‐excitation (WE), in the context of CEST MRI. Methods: "Universal" kT ‐points (for FS) and spiral non‐selective (for WE) trajectories were optimized offline for flip angle (FA) homogeneity. Routines to optimize the pulse shape online, based on the subject's fields maps, were implemented (target FA of 110°/0° for FS, 0°/5° for WE at fat/water frequencies). The pulses were inserted in a CEST sequence with a pTx readout. The different fat suppression schemes and their effects on CEST contrasts were compared in 12 volunteers at 7T. Results: With a 25%‐shorter pulse duration, pTx FS largely improved the FA homogeneity (root‐mean‐square‐error (RMSE) = 12.3° vs. 53.4° with circularly‐polarized mode, at the fat frequency). However, the spectral selectivity was degraded mainly in the cerebellum and close to the sinuses (RMSE = 5.8° vs. 0.2° at the water frequency). Similarly, pTx WE showed a trade‐off between FA homogeneity and spectral selectivity compared to pTx non‐selective pulses (RMSE = 0.9° and 1.1° at the fat and water frequencies, vs. 4.6° and 0.5°). In the brain, CEST metrics were reduced by up to 31.9% at −3.3 ppm with pTx FS, suggesting a mitigated lipid‐induced bias. Conclusion: This clinically compatible implementation of dynamic pTx pulses improved the fat suppression homogeneity at 7T taking into account the subject‐specific B0Abstract : Purpose: To evaluate the benefits and challenges of dynamic parallel transmit (pTx) pulses for fat saturation (FS) and water‐excitation (WE), in the context of CEST MRI. Methods: "Universal" kT ‐points (for FS) and spiral non‐selective (for WE) trajectories were optimized offline for flip angle (FA) homogeneity. Routines to optimize the pulse shape online, based on the subject's fields maps, were implemented (target FA of 110°/0° for FS, 0°/5° for WE at fat/water frequencies). The pulses were inserted in a CEST sequence with a pTx readout. The different fat suppression schemes and their effects on CEST contrasts were compared in 12 volunteers at 7T. Results: With a 25%‐shorter pulse duration, pTx FS largely improved the FA homogeneity (root‐mean‐square‐error (RMSE) = 12.3° vs. 53.4° with circularly‐polarized mode, at the fat frequency). However, the spectral selectivity was degraded mainly in the cerebellum and close to the sinuses (RMSE = 5.8° vs. 0.2° at the water frequency). Similarly, pTx WE showed a trade‐off between FA homogeneity and spectral selectivity compared to pTx non‐selective pulses (RMSE = 0.9° and 1.1° at the fat and water frequencies, vs. 4.6° and 0.5°). In the brain, CEST metrics were reduced by up to 31.9% at −3.3 ppm with pTx FS, suggesting a mitigated lipid‐induced bias. Conclusion: This clinically compatible implementation of dynamic pTx pulses improved the fat suppression homogeneity at 7T taking into account the subject‐specific B0 heterogeneities online. This study highlights the lipid‐induced biases on the CEST z‐spectrum. The results are promising for body applications where B0 heterogeneities and fat are more substantial. … (more)
- Is Part Of:
- Magnetic resonance in medicine. Volume 89:Issue 1(2023)
- Journal:
- Magnetic resonance in medicine
- Issue:
- Volume 89:Issue 1(2023)
- Issue Display:
- Volume 89, Issue 1 (2023)
- Year:
- 2023
- Volume:
- 89
- Issue:
- 1
- Issue Sort Value:
- 2023-0089-0001-0000
- Page Start:
- 77
- Page End:
- 94
- Publication Date:
- 2022-09-21
- Subjects:
- 7T MRI -- CEST -- dynamic pulse design -- fat saturation -- fat suppression -- parallel transmission -- water‐excitation
Nuclear magnetic resonance -- Periodicals
Electron paramagnetic resonance -- Periodicals
616.07548 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)1522-2594 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/mrm.29412 ↗
- Languages:
- English
- ISSNs:
- 0740-3194
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5337.798000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 24233.xml