Reduction of the cardiac pulsation artifact and improvement of lesion conspicuity in flow‐compensated diffusion images in the liver—A quantitative evaluation of postprocessing algorithms. Issue 1 (11th September 2022)
- Record Type:
- Journal Article
- Title:
- Reduction of the cardiac pulsation artifact and improvement of lesion conspicuity in flow‐compensated diffusion images in the liver—A quantitative evaluation of postprocessing algorithms. Issue 1 (11th September 2022)
- Main Title:
- Reduction of the cardiac pulsation artifact and improvement of lesion conspicuity in flow‐compensated diffusion images in the liver—A quantitative evaluation of postprocessing algorithms
- Authors:
- Führes, Tobit
Saake, Marc
Lorenz, Jennifer
Seuss, Hannes
Stemmer, Alto
Benkert, Thomas
Uder, Michael
Laun, Frederik Bernd - Abstract:
- Abstract : Purpose: To enhance image quality of flow‐compensated diffusion‐weighted liver MRI data by increasing the lesion conspicuity and reducing the cardiac pulsation artifact using postprocessing algorithms. Methods: Diffusion‐weighted image data of 40 patients with liver lesions had been acquired at 1.5 T. These data were postprocessed with 5 different algorithms (weighted averaging, p ‐mean, percentile, outlier exclusion, and exception set). Four image properties of the postprocessed data were evaluated for optimizing the algorithm parameters. These properties were the lesion to tissue contrast‐to‐noise ratio (CNR), the reduction of the cardiac pulsation artifact, the data consistency, and the vessel darkness. They were combined into a total quality score ( Q total, $$ {Q}_{\mathrm{total}}, $$ set to 1 for the trace‐weighted reference image), which was used to rate the image quality objectively. Results: The weighted averaging algorithm performed best according to the total quality score ( Q total = 1.111 ± 0.067 $$ {Q}_{\mathrm{total}}=1.111\pm 0.067 $$ ). The further ranking was outlier exclusion algorithm ( Q total = 1.086 ± 0.061 $$ {Q}_{\mathrm{total}}=1.086\pm 0.061 $$ ), p ‐mean algorithm ( Q total = 1.045 ± 0.049 $$ {Q}_{\mathrm{total}}=1.045\pm 0.049 $$ ), percentile algorithm ( Q total = 1.012 ± 0.049 $$ {Q}_{\mathrm{total}}=1.012\pm 0.049 $$ ), and exception set algorithm ( Q total = 0.957 ± 0.027 $$ {Q}_{\mathrm{total}}=0.957\pm 0.027 $$ ). All optimizedAbstract : Purpose: To enhance image quality of flow‐compensated diffusion‐weighted liver MRI data by increasing the lesion conspicuity and reducing the cardiac pulsation artifact using postprocessing algorithms. Methods: Diffusion‐weighted image data of 40 patients with liver lesions had been acquired at 1.5 T. These data were postprocessed with 5 different algorithms (weighted averaging, p ‐mean, percentile, outlier exclusion, and exception set). Four image properties of the postprocessed data were evaluated for optimizing the algorithm parameters. These properties were the lesion to tissue contrast‐to‐noise ratio (CNR), the reduction of the cardiac pulsation artifact, the data consistency, and the vessel darkness. They were combined into a total quality score ( Q total, $$ {Q}_{\mathrm{total}}, $$ set to 1 for the trace‐weighted reference image), which was used to rate the image quality objectively. Results: The weighted averaging algorithm performed best according to the total quality score ( Q total = 1.111 ± 0.067 $$ {Q}_{\mathrm{total}}=1.111\pm 0.067 $$ ). The further ranking was outlier exclusion algorithm ( Q total = 1.086 ± 0.061 $$ {Q}_{\mathrm{total}}=1.086\pm 0.061 $$ ), p ‐mean algorithm ( Q total = 1.045 ± 0.049 $$ {Q}_{\mathrm{total}}=1.045\pm 0.049 $$ ), percentile algorithm ( Q total = 1.012 ± 0.049 $$ {Q}_{\mathrm{total}}=1.012\pm 0.049 $$ ), and exception set algorithm ( Q total = 0.957 ± 0.027 $$ {Q}_{\mathrm{total}}=0.957\pm 0.027 $$ ). All optimized algorithms except for the exception set algorithm corrected the pulsation artifact and increased the lesion CNR. Changes in Q total $$ {Q}_{\mathrm{total}} $$ were significant for all optimized algorithms except for the percentile algorithm. Liver ADC was significantly reduced (except for the exception set algorithm), particularly in the left lobe. Conclusion: Postprocessing algorithms should be used for flow‐compensated liver DWI. The proposed weighted averaging algorithm seems to be suited best to increase the image quality of artifact‐corrupted flow‐compensated diffusion‐weighted liver data. … (more)
- Is Part Of:
- Magnetic resonance in medicine. Volume 89:Issue 1(2023)
- Journal:
- Magnetic resonance in medicine
- Issue:
- Volume 89:Issue 1(2023)
- Issue Display:
- Volume 89, Issue 1 (2023)
- Year:
- 2023
- Volume:
- 89
- Issue:
- 1
- Issue Sort Value:
- 2023-0089-0001-0000
- Page Start:
- 423
- Page End:
- 439
- Publication Date:
- 2022-09-11
- Subjects:
- algorithms -- cardiac pulsation artifact -- diffusion -- flow‐compensation -- liver -- postprocessing
Nuclear magnetic resonance -- Periodicals
Electron paramagnetic resonance -- Periodicals
616.07548 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)1522-2594 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/mrm.29427 ↗
- Languages:
- English
- ISSNs:
- 0740-3194
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5337.798000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 24233.xml