Accelerated two‐dimensional phase‐contrast for cardiovascular MRI using deep learning‐based reconstruction with complex difference estimation. Issue 1 (12th September 2022)
- Record Type:
- Journal Article
- Title:
- Accelerated two‐dimensional phase‐contrast for cardiovascular MRI using deep learning‐based reconstruction with complex difference estimation. Issue 1 (12th September 2022)
- Main Title:
- Accelerated two‐dimensional phase‐contrast for cardiovascular MRI using deep learning‐based reconstruction with complex difference estimation
- Authors:
- Oscanoa, Julio A.
Middione, Matthew J.
Syed, Ali B.
Sandino, Christopher M.
Vasanawala, Shreyas S.
Ennis, Daniel B. - Abstract:
- Abstract : Purpose: To develop and validate a deep learning‐based reconstruction framework for highly accelerated two‐dimensional (2D) phase contrast (PC‐MRI) data with accurate and precise quantitative measurements. Methods: We propose a modified DL‐ESPIRiT reconstruction framework for 2D PC‐MRI, comprised of an unrolled neural network architecture with a Complex Difference estimation (CD‐DL). CD‐DL was trained on 155 fully sampled 2D PC‐MRI pediatric clinical datasets. The fully sampled data ( n = 29 $$ n=29 $$ ) was retrospectively undersampled (6–11 × $$ \times $$ ) and reconstructed using CD‐DL and a parallel imaging and compressed sensing method (PICS). Measurements of peak velocity and total flow were compared to determine the highest acceleration rate that provided accuracy and precision within ± 5 % $$ \pm 5\% $$ . Feasibility of CD‐DL was demonstrated on prospectively undersampled datasets acquired in pediatric clinical patients ( n = 5 $$ n=5 $$ ) and compared to traditional parallel imaging (PI) and PICS. Results: The retrospective evaluation showed that 9 × $$ \times $$ accelerated 2D PC‐MRI images reconstructed with CD‐DL provided accuracy and precision (bias, [95 % $$ \% $$ confidence intervals]) within ± 5 % $$ \pm 5\% $$ . CD‐DL showed higher accuracy and precision compared to PICS for measurements of peak velocity (2.8 % $$ \% $$ [ − 2 . 9 $$ -2.9 $$, 4.5] vs. 3.9 % $$ \% $$ [ − 11 . 0 $$ -11.0 $$, 4.9]) and total flow (1.8 % $$ \% $$ [ − 3 . 9 $$ -3.9 $$,Abstract : Purpose: To develop and validate a deep learning‐based reconstruction framework for highly accelerated two‐dimensional (2D) phase contrast (PC‐MRI) data with accurate and precise quantitative measurements. Methods: We propose a modified DL‐ESPIRiT reconstruction framework for 2D PC‐MRI, comprised of an unrolled neural network architecture with a Complex Difference estimation (CD‐DL). CD‐DL was trained on 155 fully sampled 2D PC‐MRI pediatric clinical datasets. The fully sampled data ( n = 29 $$ n=29 $$ ) was retrospectively undersampled (6–11 × $$ \times $$ ) and reconstructed using CD‐DL and a parallel imaging and compressed sensing method (PICS). Measurements of peak velocity and total flow were compared to determine the highest acceleration rate that provided accuracy and precision within ± 5 % $$ \pm 5\% $$ . Feasibility of CD‐DL was demonstrated on prospectively undersampled datasets acquired in pediatric clinical patients ( n = 5 $$ n=5 $$ ) and compared to traditional parallel imaging (PI) and PICS. Results: The retrospective evaluation showed that 9 × $$ \times $$ accelerated 2D PC‐MRI images reconstructed with CD‐DL provided accuracy and precision (bias, [95 % $$ \% $$ confidence intervals]) within ± 5 % $$ \pm 5\% $$ . CD‐DL showed higher accuracy and precision compared to PICS for measurements of peak velocity (2.8 % $$ \% $$ [ − 2 . 9 $$ -2.9 $$, 4.5] vs. 3.9 % $$ \% $$ [ − 11 . 0 $$ -11.0 $$, 4.9]) and total flow (1.8 % $$ \% $$ [ − 3 . 9 $$ -3.9 $$, 3.4] vs. 2.9 % $$ \% $$ [ − 7 . 1 $$ -7.1 $$, 6.9]). The prospective feasibility study showed that CD‐DL provided higher accuracy and precision than PICS for measurements of peak velocity and total flow. Conclusion: In a retrospective evaluation, CD‐DL produced quantitative measurements of 2D PC‐MRI peak velocity and total flow with ≤ 5 % $$ \le 5\% $$ error in both accuracy and precision for up to 9 × $$ \times $$ acceleration. Clinical feasibility was demonstrated using a prospective clinical deployment of our 8 × $$ \times $$ undersampled acquisition and CD‐DL reconstruction in a cohort of pediatric patients. … (more)
- Is Part Of:
- Magnetic resonance in medicine. Volume 89:Issue 1(2023)
- Journal:
- Magnetic resonance in medicine
- Issue:
- Volume 89:Issue 1(2023)
- Issue Display:
- Volume 89, Issue 1 (2023)
- Year:
- 2023
- Volume:
- 89
- Issue:
- 1
- Issue Sort Value:
- 2023-0089-0001-0000
- Page Start:
- 356
- Page End:
- 369
- Publication Date:
- 2022-09-12
- Subjects:
- accuracy -- blood flow -- complex difference -- deep learning -- phase contrast -- precision -- velocity
Nuclear magnetic resonance -- Periodicals
Electron paramagnetic resonance -- Periodicals
616.07548 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)1522-2594 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/mrm.29441 ↗
- Languages:
- English
- ISSNs:
- 0740-3194
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5337.798000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 24233.xml