Refractive outcomes of 8 biometric formulas in combined phacovitrectomy with internal limiting membrane peeling for epiretinal membrane. Issue 4 (April 2020)
- Record Type:
- Journal Article
- Title:
- Refractive outcomes of 8 biometric formulas in combined phacovitrectomy with internal limiting membrane peeling for epiretinal membrane. Issue 4 (April 2020)
- Main Title:
- Refractive outcomes of 8 biometric formulas in combined phacovitrectomy with internal limiting membrane peeling for epiretinal membrane
- Authors:
- Vounotrypidis, Efstathios
Shajari, Mehdi
Muth, Daniel R.
Hirnschall, Nino
Findl, Oliver
Priglinger, Siegfried
Mayer, Wolfgang J. - Abstract:
- Abstract : Modern biometric formulas Kane, Holladay 2, and Barrett demonstrate higher, though not statistically significant, refractive accuracy in terms of combined phacovitrectomy for epiretinal membrane and cataract compared with previous-generation formulas. Abstract : Purpose: To investigate the accuracy of 8 different biometric formulas in combined phacovitrectomy and the effect of constant optimization on refractive outcome. Setting: Ludwig-Maximilians-University, Munich, Germany. Design: Retrospective observational case series. Methods: In this single-center study, patients with cataract and epiretinal membrane who underwent combined phacovitrectomy with internal limiting membrane peeling (Group B) and axial length–matched patients who underwent phacoemulsification (Group A) were included. In Group C, optimized constants from Group A were applied in patients of Group B. One eye of each patient was included. Main outcome measures after constant optimization for each biometric formula were refractive prediction error (PE), mean absolute error (MAE), and percentages of eyes with a PE within ±0.25 diopters (D), ±0.5 D, and ±1.0 D. Results: The study comprised 128 patients. For all formulas in Group A and Group B, refractive PE was 0.000 ( P = .964 and P = .967, respectively). For formulas Barrett, Haigis, Hill, Hoffer Q, Holladay 1, Holladay 2, Kane, and SRK-T, refractive PE was −0.147, −0.204, −0.180, −0.212, −0.180, −0.178, −0.153, and −0.159, respectively, in Group CAbstract : Modern biometric formulas Kane, Holladay 2, and Barrett demonstrate higher, though not statistically significant, refractive accuracy in terms of combined phacovitrectomy for epiretinal membrane and cataract compared with previous-generation formulas. Abstract : Purpose: To investigate the accuracy of 8 different biometric formulas in combined phacovitrectomy and the effect of constant optimization on refractive outcome. Setting: Ludwig-Maximilians-University, Munich, Germany. Design: Retrospective observational case series. Methods: In this single-center study, patients with cataract and epiretinal membrane who underwent combined phacovitrectomy with internal limiting membrane peeling (Group B) and axial length–matched patients who underwent phacoemulsification (Group A) were included. In Group C, optimized constants from Group A were applied in patients of Group B. One eye of each patient was included. Main outcome measures after constant optimization for each biometric formula were refractive prediction error (PE), mean absolute error (MAE), and percentages of eyes with a PE within ±0.25 diopters (D), ±0.5 D, and ±1.0 D. Results: The study comprised 128 patients. For all formulas in Group A and Group B, refractive PE was 0.000 ( P = .964 and P = .967, respectively). For formulas Barrett, Haigis, Hill, Hoffer Q, Holladay 1, Holladay 2, Kane, and SRK-T, refractive PE was −0.147, −0.204, −0.180, −0.212, −0.180, −0.178, −0.153, and −0.159, respectively, in Group C ( P = .569); MAE was 0.346, 0.375, 0.382, 0.379, 0.355, 0.377, 0.318, and 0.364, respectively, in Group A ( P = .286); 0.402, 0.422, 0.417, 0.427, 0.417, 0.402, 0.370, and 0.401, respectively, in Group B ( P = .364); and 0.401, 0.424, 0.419, 0.444, 0.424, 0.404, 0.391, and 0.422, respectively, in Group C ( P = .767). Effect of constant optimization in phacovitrectomy was statistically significant for all formulas ( P < .001 for each formula). Conclusions: No statistically significant difference was observed between the biometric formulas with regard to PE and MAE. However, in terms of phacovitrectomy, constant optimization should be considered for individual intraocular lens power calculations attributable to myopic shift. … (more)
- Is Part Of:
- Journal of cataract and refractive surgery. Volume 46:Issue 4(2020)
- Journal:
- Journal of cataract and refractive surgery
- Issue:
- Volume 46:Issue 4(2020)
- Issue Display:
- Volume 46, Issue 4 (2020)
- Year:
- 2020
- Volume:
- 46
- Issue:
- 4
- Issue Sort Value:
- 2020-0046-0004-0000
- Page Start:
- 591
- Page End:
- 597
- Publication Date:
- 2020-04
- Subjects:
- 617.7
- Journal URLs:
- http://journals.lww.com/pages/default.aspx ↗
- DOI:
- 10.1097/j.jcrs.0000000000000087 ↗
- Languages:
- English
- ISSNs:
- 0886-3350
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4954.900000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 24191.xml