Novel High-Resolution Imaging Using ANTERION Optical Coherence Tomography to Assess Fluid Reservoir Change in Scleral Lens Periphery. Issue 11 (8th November 2022)
- Record Type:
- Journal Article
- Title:
- Novel High-Resolution Imaging Using ANTERION Optical Coherence Tomography to Assess Fluid Reservoir Change in Scleral Lens Periphery. Issue 11 (8th November 2022)
- Main Title:
- Novel High-Resolution Imaging Using ANTERION Optical Coherence Tomography to Assess Fluid Reservoir Change in Scleral Lens Periphery
- Authors:
- Tran, Stephanie
Roberts, Cynthia J.
Mahmoud, Ashraf
Pisano, Stephanie
Mundy, Chantelle - Abstract:
- Abstract : Objectives: To assess scleral lens fluid reservoir (FR) change simultaneously in four quadrants with single acquisition using novel ANTERION anterior segment swept-source optical coherence tomography (SS-OCT). Methods: A prospective, observational, clinical study of 18 subjects (30 eyes) was performed on adults fitted with a scleral lens for ocular surface disease (n=8), irregular cornea/scar (n=7), and corneal ectasia (n=15). ANTERION anterior segment SS-OCT imaging was obtained at the initial visit and at the follow-up to determine pre and post scleral lens settling, measured in microns, centrally and peripherally. Peripheral measurements were grouped into four quadrants. Repeated-measures ANOVA was performed comparing vault post minus pre differences by quadrant, and TTests comparing difference in FR by lens design were performed with a significant threshold at P <0.05. Results: The mean central scleral lens settling was significant at −48.3±41.7 μm. The change in FR by quadrant was superior (S): −47.8±67.3 μm, inferior (I): −68.0±102.2 μm, nasal (N) −46.3±63.4 μm, and temporal (T): −56.7±49.3 μm. There were no significant differences in lens settling between the quadrants. Within the three categories, the irregular cornea group experienced significantly greater lens settling. There was no significant difference in central FR when comparing lens design or lens diameter. Conclusions: The ANTERION SS-OCT allows for high-resolution central and peripheralAbstract : Objectives: To assess scleral lens fluid reservoir (FR) change simultaneously in four quadrants with single acquisition using novel ANTERION anterior segment swept-source optical coherence tomography (SS-OCT). Methods: A prospective, observational, clinical study of 18 subjects (30 eyes) was performed on adults fitted with a scleral lens for ocular surface disease (n=8), irregular cornea/scar (n=7), and corneal ectasia (n=15). ANTERION anterior segment SS-OCT imaging was obtained at the initial visit and at the follow-up to determine pre and post scleral lens settling, measured in microns, centrally and peripherally. Peripheral measurements were grouped into four quadrants. Repeated-measures ANOVA was performed comparing vault post minus pre differences by quadrant, and TTests comparing difference in FR by lens design were performed with a significant threshold at P <0.05. Results: The mean central scleral lens settling was significant at −48.3±41.7 μm. The change in FR by quadrant was superior (S): −47.8±67.3 μm, inferior (I): −68.0±102.2 μm, nasal (N) −46.3±63.4 μm, and temporal (T): −56.7±49.3 μm. There were no significant differences in lens settling between the quadrants. Within the three categories, the irregular cornea group experienced significantly greater lens settling. There was no significant difference in central FR when comparing lens design or lens diameter. Conclusions: The ANTERION SS-OCT allows for high-resolution central and peripheral assessment of FR in scleral lens wear. With increased technology available for scleral lens customization, this imaging modality can assist in more detailed assessment in quadrant-specific scleral lens designs. … (more)
- Is Part Of:
- Eye & contact lens. Volume 48:Issue 11(2022)
- Journal:
- Eye & contact lens
- Issue:
- Volume 48:Issue 11(2022)
- Issue Display:
- Volume 48, Issue 11 (2022)
- Year:
- 2022
- Volume:
- 48
- Issue:
- 11
- Issue Sort Value:
- 2022-0048-0011-0000
- Page Start:
- 466
- Page End:
- 470
- Publication Date:
- 2022-11-08
- Subjects:
- Scleral lens -- Fluid reservoir -- Optical coherence tomography -- Irregular cornea -- Ocular surface disease
Contact lenses -- Periodicals
Intraocular lenses -- Periodicals
Orthokeratology -- Periodicals
Anterior segment (Eye) -- Diseases -- Periodicals
617.7523 - Journal URLs:
- http://journals.lww.com/claojournal/pages/default.aspx ↗
http://journals.lww.com ↗ - DOI:
- 10.1097/ICL.0000000000000937 ↗
- Languages:
- English
- ISSNs:
- 1542-2321
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3854.587000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 24200.xml