Comparison of manipulation rates for robot-assisted, customized, and conventional total knee arthroplasty: a retrospective cohort study. Issue 6 (7th November 2022)
- Record Type:
- Journal Article
- Title:
- Comparison of manipulation rates for robot-assisted, customized, and conventional total knee arthroplasty: a retrospective cohort study. Issue 6 (7th November 2022)
- Main Title:
- Comparison of manipulation rates for robot-assisted, customized, and conventional total knee arthroplasty: a retrospective cohort study
- Authors:
- Markel, Michael J.
Grieme, Caleb
Szakiel, Paulina
Abraham, Nijo
Rigor, Paolo Diaz
Geng, Xue
Lee, Ji Won
Boucher, Henry R. - Abstract:
- Abstract : Background: With projected increases in total knee arthroplasties (TKA), patient outcomes without complications are essential. Arthrofibrosis, a potential complication after TKA that may impact long-term patient outcome, may be remedied by manipulation under anesthesia (MUA); however, it is not risk-free. This study investigated the association between manipulation and newer implants and sophisticated techniques, which hold promise for preventing arthrofibrosis and improving patient outcomes. Methods: The authors retrospectively reviewed 1260 primary knee arthroplasty cases (717 conventional, 217 customized, and 326 robot-assisted) performed by an orthopaedic surgeon from January 1, 2016 to May 31, 2020. Patient records were reviewed for manipulation and demographics (type of implant, sex, body mass index [BMI], smoking status, and prior surgery). Results: Overall manipulation rate was 1.3% (n=17). Manipulation rates for conventional customized and robot-assisted TKAs did not vary significantly (1.84%, n=6; 0.46%, n=1; 1.39%, n=10, respectively; P =0.466). Multivariable logistic regression showed no statistically significant difference in the odds of manipulation depending on the type of implant. However, those who smoked were 4 times more likely to have a manipulation (OR: 4.187, 95% CI: 1.119 to 15.673) when controlling for covariates (type of implant, sex, BMI, and prior surgery). Additionally, those with prior surgery were 2.8 times as likely to have aAbstract : Background: With projected increases in total knee arthroplasties (TKA), patient outcomes without complications are essential. Arthrofibrosis, a potential complication after TKA that may impact long-term patient outcome, may be remedied by manipulation under anesthesia (MUA); however, it is not risk-free. This study investigated the association between manipulation and newer implants and sophisticated techniques, which hold promise for preventing arthrofibrosis and improving patient outcomes. Methods: The authors retrospectively reviewed 1260 primary knee arthroplasty cases (717 conventional, 217 customized, and 326 robot-assisted) performed by an orthopaedic surgeon from January 1, 2016 to May 31, 2020. Patient records were reviewed for manipulation and demographics (type of implant, sex, body mass index [BMI], smoking status, and prior surgery). Results: Overall manipulation rate was 1.3% (n=17). Manipulation rates for conventional customized and robot-assisted TKAs did not vary significantly (1.84%, n=6; 0.46%, n=1; 1.39%, n=10, respectively; P =0.466). Multivariable logistic regression showed no statistically significant difference in the odds of manipulation depending on the type of implant. However, those who smoked were 4 times more likely to have a manipulation (OR: 4.187, 95% CI: 1.119 to 15.673) when controlling for covariates (type of implant, sex, BMI, and prior surgery). Additionally, those with prior surgery were 2.8 times as likely to have a manipulation (OR: 2.808, 95% CI: 1.039 to 7.589) when controlling for covariates. Conclusions: There were no statistically significant differences in manipulation rates among conventional, customized, and robot-assisted TKAs. However, current smoking status and prior surgery were associated with higher risk of manipulation. Level of Evidence: Level III. … (more)
- Is Part Of:
- Current orthopaedic practice. Volume 33:Issue 6(2022)
- Journal:
- Current orthopaedic practice
- Issue:
- Volume 33:Issue 6(2022)
- Issue Display:
- Volume 33, Issue 6 (2022)
- Year:
- 2022
- Volume:
- 33
- Issue:
- 6
- Issue Sort Value:
- 2022-0033-0006-0000
- Page Start:
- 565
- Page End:
- 570
- Publication Date:
- 2022-11-07
- Subjects:
- customized TKA -- manipulation under anesthesia -- robot-assisted TKA -- total knee arthroplasty
Orthopedics -- Periodicals
616.7005 - Journal URLs:
- http://ovidsp.ovid.com/ovidweb.cgi?T=JS&NEWS=N&PAGE=toc&SEARCH=01337441-000000000-00000.kc&LINKTYPE=asBody&LINKPOS=1&D=ovft ↗
http://www.c-orthopaedicpractice.com ↗
http://journals.lww.com/pages/default.aspx ↗ - DOI:
- 10.1097/BCO.0000000000001176 ↗
- Languages:
- English
- ISSNs:
- 1940-7041
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3500.835000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 24188.xml