Corneal diameter measurements by 3 optical biometers and their effect on phakic intraocular lens sizing. Issue 11 (November 2022)
- Record Type:
- Journal Article
- Title:
- Corneal diameter measurements by 3 optical biometers and their effect on phakic intraocular lens sizing. Issue 11 (November 2022)
- Main Title:
- Corneal diameter measurements by 3 optical biometers and their effect on phakic intraocular lens sizing
- Authors:
- Savini, Giacomo
Lupardi, Enrico
Hoffer, Kenneth J.
Aramberri, Jaime
Schiano-Lomoriello, Domenico - Abstract:
- Abstract : Corneal diameter measurements obtained with 3 optical biometers led to similar percentages (approximately 70%) of eyes with a phakic intraocular lens size equal to the optimal value. Abstract : Purpose: To compare phakic intraocular lens size calculations based on corneal diameter (CD) measurements by 3 instruments. Setting: G.B. Bietti Foundation I.R.C.C.S., Rome, Italy. Design: Retrospective interventional case series. Methods: Preoperatively, CD was measured with the Aladdin, IOLMaster 700, and Pentacam AXL Wave. The simulated ICL size was computed by entering CD measurements into the manufacturer's calculator. Postoperatively, vaulting was measured by anterior segment optical coherence tomography. The optimal ICL size (OIS) was calculated and compared with the commercially available OIS (CAOIS). Results: 54 eyes (29 patients) with the implantable collamer lens (ICL) were enrolled. The mean CD was 12.02 ± 0.36 mm with the Aladdin, 12.35 ± 0.39 mm with the IOLMaster 700, and 12.22 ± 0.41 mm with the Pentacam AXL Wave ( P < .0001), with the closest agreement between the Pentacam AXL Wave and IOLMaster 700 (95% limits of agreement: −0.43 to +0.17 mm). Vaulting (mean: 558 ± 261 μm) was within 251 and 1000 μm in 49 eyes (83.3%). The mean difference between the simulated ICL size and OIS ranged between −0.11 ± 0.35 mm and 0.10 ± 0.30 mm ( P < .0001), with no statistically significant difference between the IOLMaster 700 and Pentacam AXL Wave. The simulated ICL sizeAbstract : Corneal diameter measurements obtained with 3 optical biometers led to similar percentages (approximately 70%) of eyes with a phakic intraocular lens size equal to the optimal value. Abstract : Purpose: To compare phakic intraocular lens size calculations based on corneal diameter (CD) measurements by 3 instruments. Setting: G.B. Bietti Foundation I.R.C.C.S., Rome, Italy. Design: Retrospective interventional case series. Methods: Preoperatively, CD was measured with the Aladdin, IOLMaster 700, and Pentacam AXL Wave. The simulated ICL size was computed by entering CD measurements into the manufacturer's calculator. Postoperatively, vaulting was measured by anterior segment optical coherence tomography. The optimal ICL size (OIS) was calculated and compared with the commercially available OIS (CAOIS). Results: 54 eyes (29 patients) with the implantable collamer lens (ICL) were enrolled. The mean CD was 12.02 ± 0.36 mm with the Aladdin, 12.35 ± 0.39 mm with the IOLMaster 700, and 12.22 ± 0.41 mm with the Pentacam AXL Wave ( P < .0001), with the closest agreement between the Pentacam AXL Wave and IOLMaster 700 (95% limits of agreement: −0.43 to +0.17 mm). Vaulting (mean: 558 ± 261 μm) was within 251 and 1000 μm in 49 eyes (83.3%). The mean difference between the simulated ICL size and OIS ranged between −0.11 ± 0.35 mm and 0.10 ± 0.30 mm ( P < .0001), with no statistically significant difference between the IOLMaster 700 and Pentacam AXL Wave. The simulated ICL size was equal to CAOIS in 38 eyes (70.37%) with the Aladdin, 37 eyes (68.52%) with the IOLMaster 700, and 39 eyes (72.22%) with the Pentacam AXL Wave, without any statistically significant difference. Conclusions: CD measurements by the 3 devices lead to similar percentages of eyes with an ICL size equal to the OIS. Agreement is closer between the IOLMaster 700 and Pentacam AXL Wave. … (more)
- Is Part Of:
- Journal of cataract and refractive surgery. Volume 48:Issue 11(2022)
- Journal:
- Journal of cataract and refractive surgery
- Issue:
- Volume 48:Issue 11(2022)
- Issue Display:
- Volume 48, Issue 11 (2022)
- Year:
- 2022
- Volume:
- 48
- Issue:
- 11
- Issue Sort Value:
- 2022-0048-0011-0000
- Page Start:
- 1292
- Page End:
- 1296
- Publication Date:
- 2022-11
- Subjects:
- 617.7
- Journal URLs:
- http://journals.lww.com/pages/default.aspx ↗
- DOI:
- 10.1097/j.jcrs.0000000000000976 ↗
- Languages:
- English
- ISSNs:
- 0886-3350
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4954.900000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 24195.xml