The effect of custom carbon ankle-foot orthosis alignment on roll-over shape and center of pressure velocity. Issue 2 (April 2021)
- Record Type:
- Journal Article
- Title:
- The effect of custom carbon ankle-foot orthosis alignment on roll-over shape and center of pressure velocity. Issue 2 (April 2021)
- Main Title:
- The effect of custom carbon ankle-foot orthosis alignment on roll-over shape and center of pressure velocity
- Authors:
- Russell Esposito, Elizabeth
Ruble, Mitchell D
Ikeda, Andrea J
Wilken, Jason M - Abstract:
- Abstract : Background: Maintaining an optimal rolling of the foot over the ground is thought to increase the stability and efficiency of pathologic gait. Ankle-foot orthoses are often prescribed to improve gait mechanics in individuals with lower extremity injuries; however, their design may compromise how the foot rolls over the ground. Objectives: The aim of this study was to investigate the effects of the sagittal plane ankle-foot orthosis alignment on roll-over shape and center of pressure velocity in individuals with lower limb reconstructions. Study design: Randomized cross-over study with a control group comparison. Methods: In total, 12 individuals with lower limb reconstruction who used a custom carbon ankle-foot orthosis and 12 uninjured controls underwent gait analysis. Ankle-foot orthosis users were tested in their clinically-provided ankle-foot orthosis alignment, with an alignment that was 3° more plantarflexed, and with an alignment that was 3° more dorsiflexed. Components of roll-over shape and center of pressure velocity were calculated from heel strike on the ankle-foot orthosis limb to contralateral heel strike. Results: Roll-over shape radius was not affected by 3° changes to alignment and was not significantly different from controls. Aligning the ankle-foot orthosis in more dorsiflexion than clinically provided resulted in a smaller peak center of pressure velocity that occurred later in stance. Conclusion: Individuals using custom carbon ankle-footAbstract : Background: Maintaining an optimal rolling of the foot over the ground is thought to increase the stability and efficiency of pathologic gait. Ankle-foot orthoses are often prescribed to improve gait mechanics in individuals with lower extremity injuries; however, their design may compromise how the foot rolls over the ground. Objectives: The aim of this study was to investigate the effects of the sagittal plane ankle-foot orthosis alignment on roll-over shape and center of pressure velocity in individuals with lower limb reconstructions. Study design: Randomized cross-over study with a control group comparison. Methods: In total, 12 individuals with lower limb reconstruction who used a custom carbon ankle-foot orthosis and 12 uninjured controls underwent gait analysis. Ankle-foot orthosis users were tested in their clinically-provided ankle-foot orthosis alignment, with an alignment that was 3° more plantarflexed, and with an alignment that was 3° more dorsiflexed. Components of roll-over shape and center of pressure velocity were calculated from heel strike on the ankle-foot orthosis limb to contralateral heel strike. Results: Roll-over shape radius was not affected by 3° changes to alignment and was not significantly different from controls. Aligning the ankle-foot orthosis in more dorsiflexion than clinically provided resulted in a smaller peak center of pressure velocity that occurred later in stance. Conclusion: Individuals using custom carbon ankle-foot orthoses can accommodate 3° alterations in the dorsiflexion or plantarflexion alignment. … (more)
- Is Part Of:
- Prosthetics and orthotics international. Volume 45:Issue 2(2021)
- Journal:
- Prosthetics and orthotics international
- Issue:
- Volume 45:Issue 2(2021)
- Issue Display:
- Volume 45, Issue 2 (2021)
- Year:
- 2021
- Volume:
- 45
- Issue:
- 2
- Issue Sort Value:
- 2021-0045-0002-0000
- Page Start:
- 147
- Page End:
- 152
- Publication Date:
- 2021-04
- Subjects:
- Intrepid dynamic exoskeletal orthosis -- rocker -- dynamic ankle-foot orthosis -- gait -- biomechanics
Orthopedic apparatus -- Periodicals
Prosthesis -- Periodicals
Implants, Artificial -- Periodicals
617.905 - Journal URLs:
- http://poi.sagepub.com/content/by/year ↗
https://journals.lww.com/poijournal/pages/default.aspx ↗
http://www.uk.sagepub.com/home.nav ↗
http://informahealthcare.com/loi/poi ↗
http://www.tandf.co.uk/journals/titles/03093646.asp ↗ - DOI:
- 10.1177/0309364620971407 ↗
- Languages:
- English
- ISSNs:
- 0309-3646
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 6935.500000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 24202.xml