Comparison of clinical outcomes of 3 trifocal IOLs. Issue 9 (September 2020)
- Record Type:
- Journal Article
- Title:
- Comparison of clinical outcomes of 3 trifocal IOLs. Issue 9 (September 2020)
- Main Title:
- Comparison of clinical outcomes of 3 trifocal IOLs
- Authors:
- Ribeiro, Filomena
Ferreira, Tiago B. - Abstract:
- Abstract : Three trifocal IOLs provided a complete visual restoration with good visual quality outcomes. Abstract : Purpose: To compare the clinical outcomes obtained after implantation of 1 of 3 models of diffractive trifocal IOLs. Setting: Hospital da Luz, Lisbon, Portugal. Design: Prospective randomized comparative study. Methods: Patients undergoing cataract surgery with bilateral implantation of 1 of 3 models of diffractive trifocal IOLs were enrolled. The IOL models implanted were the FineVision POD F, RayOne Trifocal, or the AcrySof IQ PanOptix IOL (30 eyes of 15 patients in each group). Visual acuity (VA), refraction, defocus curve, and contrast sensitivity outcomes were evaluated during a 3-month follow-up. Furthermore, the Quality of Vision questionnaire (QoV) was used to evaluate the frequency, severity, and discomfort of different visual symptoms. Results: A total of 90 eyes of 45 patients were included. No statistically significant differences were found between groups in distance, intermediate, and near VA ( P ≥ .112) and postoperative refraction ( P ≥ .059). Postoperative binocular uncorrected intermediate VA of 0.10 logarithm of the minimum angle of resolution (logMAR) or better was found in 14 (93.33%) patients in the 3 groups. Postoperative binocular uncorrected near VA of 0.10 logMAR or better was found in 13 (86.67%), 14 (93.33%), and 13 (86.67%) patients in the POD F, RayOne, and PanOptix IOLs groups, respectively. No statistically significantAbstract : Three trifocal IOLs provided a complete visual restoration with good visual quality outcomes. Abstract : Purpose: To compare the clinical outcomes obtained after implantation of 1 of 3 models of diffractive trifocal IOLs. Setting: Hospital da Luz, Lisbon, Portugal. Design: Prospective randomized comparative study. Methods: Patients undergoing cataract surgery with bilateral implantation of 1 of 3 models of diffractive trifocal IOLs were enrolled. The IOL models implanted were the FineVision POD F, RayOne Trifocal, or the AcrySof IQ PanOptix IOL (30 eyes of 15 patients in each group). Visual acuity (VA), refraction, defocus curve, and contrast sensitivity outcomes were evaluated during a 3-month follow-up. Furthermore, the Quality of Vision questionnaire (QoV) was used to evaluate the frequency, severity, and discomfort of different visual symptoms. Results: A total of 90 eyes of 45 patients were included. No statistically significant differences were found between groups in distance, intermediate, and near VA ( P ≥ .112) and postoperative refraction ( P ≥ .059). Postoperative binocular uncorrected intermediate VA of 0.10 logarithm of the minimum angle of resolution (logMAR) or better was found in 14 (93.33%) patients in the 3 groups. Postoperative binocular uncorrected near VA of 0.10 logMAR or better was found in 13 (86.67%), 14 (93.33%), and 13 (86.67%) patients in the POD F, RayOne, and PanOptix IOLs groups, respectively. No statistically significant differences were found between groups in scotopic contrast sensitivity with and without glare and in the QoV scores ( P ≥ .057), except for the difference between the POD F and RayOne IOLs groups in depth perception severity, which was less in the RayOne IOL group ( P = .019). Conclusions: The 3 trifocal IOLs evaluated provided a complete visual restoration with good visual quality outcomes. … (more)
- Is Part Of:
- Journal of cataract and refractive surgery. Volume 46:Issue 9(2020)
- Journal:
- Journal of cataract and refractive surgery
- Issue:
- Volume 46:Issue 9(2020)
- Issue Display:
- Volume 46, Issue 9 (2020)
- Year:
- 2020
- Volume:
- 46
- Issue:
- 9
- Issue Sort Value:
- 2020-0046-0009-0000
- Page Start:
- 1247
- Page End:
- 1252
- Publication Date:
- 2020-09
- Subjects:
- 617.7
- Journal URLs:
- http://journals.lww.com/pages/default.aspx ↗
- DOI:
- 10.1097/j.jcrs.0000000000000212 ↗
- Languages:
- English
- ISSNs:
- 0886-3350
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4954.900000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 24191.xml