Frameless Robot-Assisted vs Frame-Based Awake Deep Brain Stimulation Surgery: An Evaluation of Technique and New Challenges. Issue 3 (6th March 2022)
- Record Type:
- Journal Article
- Title:
- Frameless Robot-Assisted vs Frame-Based Awake Deep Brain Stimulation Surgery: An Evaluation of Technique and New Challenges. Issue 3 (6th March 2022)
- Main Title:
- Frameless Robot-Assisted vs Frame-Based Awake Deep Brain Stimulation Surgery: An Evaluation of Technique and New Challenges
- Authors:
- Fenoy, Albert J.
Conner, Christopher R. - Abstract:
- Abstract : BACKGROUND: Methodological approaches to deep brain stimulation (DBS) continue to evolve from awake frame-based to asleep frameless procedures with robotic assistance, primarily directed to optimize operative efficiency, lead accuracy, and patient comfort. Comparison between the 2 is scarce. OBJECTIVE: To analyze the impacts of methodological differences on operative efficiency and stereotactic accuracy using a frame compared with a frameless robotic platform while maintaining the awake state and use of multiple microelectrode recording (MER) trajectories. METHODS: Thirty-four consecutive patients who underwent bilateral awake frameless robot-assisted DBS were compared with a previous cohort of 30 patients who underwent frame-based surgery. Patient demographics, operative times, and MER data were collected for both cohorts. Two-dimensional radial errors of lead placements were calculated. RESULTS: Preoperative setup, surgical, and total operating room times were all significantly greater for the robot-assisted cohort ( P < .001). The need for computed tomography imaging when referencing the robotic fiducials led to increased setup duration because of patient transport, unnecessary for the frame-based cohort. Multiple simultaneous MER trajectories increased surgical time (mean 26 min) for the robot-assisted cohort only. The mean radial errors in the robot-assisted and frame cohorts were 0.98 ± 0.66 and 0.74 ± 0.49 mm ( P = .03), respectively. CONCLUSION: The use ofAbstract : BACKGROUND: Methodological approaches to deep brain stimulation (DBS) continue to evolve from awake frame-based to asleep frameless procedures with robotic assistance, primarily directed to optimize operative efficiency, lead accuracy, and patient comfort. Comparison between the 2 is scarce. OBJECTIVE: To analyze the impacts of methodological differences on operative efficiency and stereotactic accuracy using a frame compared with a frameless robotic platform while maintaining the awake state and use of multiple microelectrode recording (MER) trajectories. METHODS: Thirty-four consecutive patients who underwent bilateral awake frameless robot-assisted DBS were compared with a previous cohort of 30 patients who underwent frame-based surgery. Patient demographics, operative times, and MER data were collected for both cohorts. Two-dimensional radial errors of lead placements were calculated. RESULTS: Preoperative setup, surgical, and total operating room times were all significantly greater for the robot-assisted cohort ( P < .001). The need for computed tomography imaging when referencing the robotic fiducials led to increased setup duration because of patient transport, unnecessary for the frame-based cohort. Multiple simultaneous MER trajectories increased surgical time (mean 26 min) for the robot-assisted cohort only. The mean radial errors in the robot-assisted and frame cohorts were 0.98 ± 0.66 and 0.74 ± 0.49 mm ( P = .03), respectively. CONCLUSION: The use of a truly frameless robotic platform such as the Mazor Renaissance (Mazor Robotics Ltd) presented challenges when implementing techniques used during awake frame-based surgery. Maintaining good accuracy, intraoperative reference imaging, and limited MER trajectories will help integrate frameless robot assistance into the awake DBS surgical workflow. … (more)
- Is Part Of:
- Operative neurosurgery. Volume 22:Issue 3(2022)
- Journal:
- Operative neurosurgery
- Issue:
- Volume 22:Issue 3(2022)
- Issue Display:
- Volume 22, Issue 3 (2022)
- Year:
- 2022
- Volume:
- 22
- Issue:
- 3
- Issue Sort Value:
- 2022-0022-0003-0000
- Page Start:
- 171
- Page End:
- 178
- Publication Date:
- 2022-03-06
- Subjects:
- Deep brain stimulation -- Robotics -- Frameless -- Frame-based -- Operative methodology
Nervous system -- Surgery -- Periodicals
617.480590 - Journal URLs:
- https://academic.oup.com/ons/issue ↗
http://journals.lww.com/onsonline/pages/default.aspx ↗
http://journals.lww.com/pages/default.aspx ↗ - DOI:
- 10.1227/ONS.0000000000000059 ↗
- Languages:
- English
- ISSNs:
- 2332-4252
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 6269.380200
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 24184.xml