Comparison of refractive outcomes after combined cataract and glaucoma surgery: trabeculectomy and glaucoma drainage device implantation. Issue 9 (September 2021)
- Record Type:
- Journal Article
- Title:
- Comparison of refractive outcomes after combined cataract and glaucoma surgery: trabeculectomy and glaucoma drainage device implantation. Issue 9 (September 2021)
- Main Title:
- Comparison of refractive outcomes after combined cataract and glaucoma surgery: trabeculectomy and glaucoma drainage device implantation
- Authors:
- Asano, Shotaro
Koh, Teck Chang Victor
Aquino, Maria Cecilia
Lim, Ka-Ann Dawn
Sng, Chelvin Cheryl Anges
Loon, Seng Chee
Chew, Tec Kuan Paul - Abstract:
- Abstract : Although the refractive outcome tended to fluctuate in short axial length eyes, the refractive prediction error after combined cataract surgery and glaucoma drainage device implantation was relatively small. Abstract : Purpose: To investigate the refractive outcome of combined cataract surgery and glaucoma drainage device (GDD) implantation compared with trabeculectomy and cataract surgery. Setting: Department of Ophthalmology, National University Health System, Singapore. Design: Retrospective cohort study. Methods: 206 eyes were enrolled for analysis: 50 had combined cataract surgery and trabeculectomy (trabeculectomy group), 50 had combined cataract surgery and GDD implantation (GDD group), and 106 had cataract surgery alone (control group). Refractive prediction error and absolute prediction error of each glaucoma surgery group were compared with the control group. Subgroup analysis was performed in the following axial length (AL) subgroups: short (<22.5 mm), medium (≥22.5 to <25.5 mm), and long (≥25.5 mm). Results: In total, 206 eyes were examined. There was no statistically significant difference in the overall refractive prediction error between the GDD (0.00 ± 0.54 diopters [D]) and the control group (0.10 ± 0.53 D, P = .58). There was significant myopic refractive prediction error in the trabeculectomy group (−0.18 ± 0.88 D, P = .020). In eyes with short AL, a greater absolute prediction error was observed in the GDD group (−0.75 ± 0.43 D, P = .039).Abstract : Although the refractive outcome tended to fluctuate in short axial length eyes, the refractive prediction error after combined cataract surgery and glaucoma drainage device implantation was relatively small. Abstract : Purpose: To investigate the refractive outcome of combined cataract surgery and glaucoma drainage device (GDD) implantation compared with trabeculectomy and cataract surgery. Setting: Department of Ophthalmology, National University Health System, Singapore. Design: Retrospective cohort study. Methods: 206 eyes were enrolled for analysis: 50 had combined cataract surgery and trabeculectomy (trabeculectomy group), 50 had combined cataract surgery and GDD implantation (GDD group), and 106 had cataract surgery alone (control group). Refractive prediction error and absolute prediction error of each glaucoma surgery group were compared with the control group. Subgroup analysis was performed in the following axial length (AL) subgroups: short (<22.5 mm), medium (≥22.5 to <25.5 mm), and long (≥25.5 mm). Results: In total, 206 eyes were examined. There was no statistically significant difference in the overall refractive prediction error between the GDD (0.00 ± 0.54 diopters [D]) and the control group (0.10 ± 0.53 D, P = .58). There was significant myopic refractive prediction error in the trabeculectomy group (−0.18 ± 0.88 D, P = .020). In eyes with short AL, a greater absolute prediction error was observed in the GDD group (−0.75 ± 0.43 D, P = .039). Conclusions: Apart from a significant deviation in short AL eyes, combined cataract surgery and GDD implantation demonstrated no significant postoperative refractive prediction error. … (more)
- Is Part Of:
- Journal of cataract and refractive surgery. Volume 47:Issue 9(2021)
- Journal:
- Journal of cataract and refractive surgery
- Issue:
- Volume 47:Issue 9(2021)
- Issue Display:
- Volume 47, Issue 9 (2021)
- Year:
- 2021
- Volume:
- 47
- Issue:
- 9
- Issue Sort Value:
- 2021-0047-0009-0000
- Page Start:
- 1133
- Page End:
- 1138
- Publication Date:
- 2021-09
- Subjects:
- 617.7
- Journal URLs:
- http://journals.lww.com/pages/default.aspx ↗
- DOI:
- 10.1097/j.jcrs.0000000000000610 ↗
- Languages:
- English
- ISSNs:
- 0886-3350
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4954.900000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 24194.xml