Multicenter visual outcomes comparison of 2 trifocal presbyopia-correcting IOLs: 6-month postoperative results. Issue 11 (November 2020)
- Record Type:
- Journal Article
- Title:
- Multicenter visual outcomes comparison of 2 trifocal presbyopia-correcting IOLs: 6-month postoperative results. Issue 11 (November 2020)
- Main Title:
- Multicenter visual outcomes comparison of 2 trifocal presbyopia-correcting IOLs: 6-month postoperative results
- Authors:
- Lapid-Gortzak, Ruth
Bhatt, Uday
Sanchez, Juan Gonzalo
Guarro, Mercè
Hida, Wilson Takashi
Bala, Chandra
Nosé, Ricardo Menon
Rodriguez Alvira, Francisco Jose
Martinez, Aldo - Abstract:
- Abstract : Compared with the 839MP IOL, the TFNT00 multifocal presbyopia-correcting IOL had improved vision for near and intermediate distances and provided comparable distance vision and contrast sensitivity. Abstract : Purpose: To clinically evaluate visual performance of the AcrySof IQ PanOptix TFNT00 and AT LISA tri 839MP intraocular lenses (IOLs) in binocular visual acuity (VA) and to characterize low-contrast visual performance at 6 months postimplantation. Setting: Multicenter, 15 sites. Design: Prospective, parallel-group, randomized, double-masked, postmarketing clinical study. Methods: Binocular uncorrected distance (UDVA, 4 m), intermediate (UIVA, 60 cm), and near (UNVA, 40 cm) visual acuities and binocular defocus curves were evaluated under photopic lighting conditions. Photopic and mesopic contrast sensitivities with and without glare were assessed. Results: The study included 182 subjects (62% women; mean age, 66 ± 9.4 years) who were implanted bilaterally with the TFNT00 IOL (n = 93) or 839MP IOL (n = 89), and binocular VA was evaluated 4 to 6 months (120–180 days) postimplantation. The TFNT00 IOL group showed superior visual outcomes compared with the 839MP IOL group in binocular UIVA ( P = .001) and UNVA ( P = .003) and noninferior outcomes in UDVA (95% CI, −0.023 to 0.041; upper limit <0.1 logarithm of the minimum angle of resolution [logMAR] [margin of noninferiority]). Mean defocus curve from 0.00 to −3.00 diopter (D) ranged from 0.1 to 0.0 logMAR forAbstract : Compared with the 839MP IOL, the TFNT00 multifocal presbyopia-correcting IOL had improved vision for near and intermediate distances and provided comparable distance vision and contrast sensitivity. Abstract : Purpose: To clinically evaluate visual performance of the AcrySof IQ PanOptix TFNT00 and AT LISA tri 839MP intraocular lenses (IOLs) in binocular visual acuity (VA) and to characterize low-contrast visual performance at 6 months postimplantation. Setting: Multicenter, 15 sites. Design: Prospective, parallel-group, randomized, double-masked, postmarketing clinical study. Methods: Binocular uncorrected distance (UDVA, 4 m), intermediate (UIVA, 60 cm), and near (UNVA, 40 cm) visual acuities and binocular defocus curves were evaluated under photopic lighting conditions. Photopic and mesopic contrast sensitivities with and without glare were assessed. Results: The study included 182 subjects (62% women; mean age, 66 ± 9.4 years) who were implanted bilaterally with the TFNT00 IOL (n = 93) or 839MP IOL (n = 89), and binocular VA was evaluated 4 to 6 months (120–180 days) postimplantation. The TFNT00 IOL group showed superior visual outcomes compared with the 839MP IOL group in binocular UIVA ( P = .001) and UNVA ( P = .003) and noninferior outcomes in UDVA (95% CI, −0.023 to 0.041; upper limit <0.1 logarithm of the minimum angle of resolution [logMAR] [margin of noninferiority]). Mean defocus curve from 0.00 to −3.00 diopter (D) ranged from 0.1 to 0.0 logMAR for both IOLs; better mean VA values (logMAR) were observed in the TFNT00 IOL group between −1.50 and −2.50 D compared with those of the 839MP IOL group. Contrast sensitivity values were similar between the 2 groups in all conditions. Conclusions: The results of this study showed improved visual performance at near and intermediate distances with the TFNT00 IOL compared with that of the 839MP IOL. … (more)
- Is Part Of:
- Journal of cataract and refractive surgery. Volume 46:Issue 11(2020)
- Journal:
- Journal of cataract and refractive surgery
- Issue:
- Volume 46:Issue 11(2020)
- Issue Display:
- Volume 46, Issue 11 (2020)
- Year:
- 2020
- Volume:
- 46
- Issue:
- 11
- Issue Sort Value:
- 2020-0046-0011-0000
- Page Start:
- 1534
- Page End:
- 1542
- Publication Date:
- 2020-11
- Subjects:
- 617.7
- Journal URLs:
- http://journals.lww.com/pages/default.aspx ↗
- DOI:
- 10.1097/j.jcrs.0000000000000274 ↗
- Languages:
- English
- ISSNs:
- 0886-3350
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4954.900000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 24193.xml