Oxide Formation and Instrumental Mass Bias in MC‐ICP‐MS: An Isotopic Case Study of Neodymium. Issue 3 (28th April 2021)
- Record Type:
- Journal Article
- Title:
- Oxide Formation and Instrumental Mass Bias in MC‐ICP‐MS: An Isotopic Case Study of Neodymium. Issue 3 (28th April 2021)
- Main Title:
- Oxide Formation and Instrumental Mass Bias in MC‐ICP‐MS: An Isotopic Case Study of Neodymium
- Authors:
- Frères, Evelyn
Weis, Dominique
Newman, Karla
Amini, Marghaleray
Gordon, Kathy - Abstract:
- Abstract : High rates of oxide formation affect the magnitude and behaviour of instrumental mass bias for Nd isotopic measurements performed with multi‐collector inductively coupled plasma‐mass spectrometry (MC‐ICP‐MS) instruments, causing the traditional correction methods (e.g., internal and external normalisation) to fail. Here, we investigate the instrumental conditions that govern oxide formation and provide an extensive data set describing how different oxide formation rates affect the measurement error of Nd isotopic ratios. Results are reported for several instrumental set‐ups including wet and dry plasma, different introduction methods, the addition of N2, and various sampler and skimmer cone geometries. The differences in the behaviour of Nd isotopic ratios observed for dry and wet plasma require several reaction mechanisms to explain why oxide formation is associated with a non‐linear mass bias for some rare earth elements. We developed a simple mathematical model to describe the behaviour of Nd isotopic ratios for a range of oxide formation rates and different instrumental settings and present a qualitative model that predicts the isotopic offsets of Nd ratios based on the cumulative contributions of the major sources of mass bias. A series of analytical recommendations for the determination of accurate and precise Nd ratios by MC‐ICP‐MS is presented. Abstract : Key Points Characterisation of Nd ratios in MC‐ICP‐MS for varying Nd oxide levels and instrumentAbstract : High rates of oxide formation affect the magnitude and behaviour of instrumental mass bias for Nd isotopic measurements performed with multi‐collector inductively coupled plasma‐mass spectrometry (MC‐ICP‐MS) instruments, causing the traditional correction methods (e.g., internal and external normalisation) to fail. Here, we investigate the instrumental conditions that govern oxide formation and provide an extensive data set describing how different oxide formation rates affect the measurement error of Nd isotopic ratios. Results are reported for several instrumental set‐ups including wet and dry plasma, different introduction methods, the addition of N2, and various sampler and skimmer cone geometries. The differences in the behaviour of Nd isotopic ratios observed for dry and wet plasma require several reaction mechanisms to explain why oxide formation is associated with a non‐linear mass bias for some rare earth elements. We developed a simple mathematical model to describe the behaviour of Nd isotopic ratios for a range of oxide formation rates and different instrumental settings and present a qualitative model that predicts the isotopic offsets of Nd ratios based on the cumulative contributions of the major sources of mass bias. A series of analytical recommendations for the determination of accurate and precise Nd ratios by MC‐ICP‐MS is presented. Abstract : Key Points Characterisation of Nd ratios in MC‐ICP‐MS for varying Nd oxide levels and instrument settings. Differences in behaviour for dry and wet plasma require several reaction mechanisms to explain the relationship between oxide formation and non‐linear mass bias. We propose two models to describe the oxide‐dependent behaviour of Nd in MC‐ICP‐MS. … (more)
- Is Part Of:
- Geostandards and geoanalytical research. Volume 45:Issue 3(2021)
- Journal:
- Geostandards and geoanalytical research
- Issue:
- Volume 45:Issue 3(2021)
- Issue Display:
- Volume 45, Issue 3 (2021)
- Year:
- 2021
- Volume:
- 45
- Issue:
- 3
- Issue Sort Value:
- 2021-0045-0003-0000
- Page Start:
- 501
- Page End:
- 523
- Publication Date:
- 2021-04-28
- Subjects:
- MC‐ICP‐MS -- neodymium -- isotope measurement -- instrumental mass bias -- oxide formation
Analytical geochemistry -- Periodicals
Géochimie analytique -- Périodiques
551.9 - Journal URLs:
- http://www.blackwell-synergy.com/loi/ggr ↗
http://www.blackwellpublishing.com/journal.asp?ref=1639-4488&site=1 ↗
http://onlinelibrary.wiley.com/journal/10.1111/(ISSN)1751-908X ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1111/ggr.12381 ↗
- Languages:
- English
- ISSNs:
- 1639-4488
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4158.896700
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 24182.xml