Comparison between wrap around screens and a head mounted display on driver muscle and kinematic responses to a pedestrian hazard. (January 2023)
- Record Type:
- Journal Article
- Title:
- Comparison between wrap around screens and a head mounted display on driver muscle and kinematic responses to a pedestrian hazard. (January 2023)
- Main Title:
- Comparison between wrap around screens and a head mounted display on driver muscle and kinematic responses to a pedestrian hazard
- Authors:
- Filio, Danielle
Ziraldo, Erika
Dony, Lynn
Gonzalez, Diego
Oliver, Michele - Abstract:
- Abstract: As driving performance relies heavily on the interpretation of visual information, driving simulators require a visual display that can effectively communicate the virtual environment to the driver. Most high-fidelity visual displays include an expensive system of high-definition projectors and wraparound screens. To reduce the overall cost of a driving simulator while preserving the generalizability of results to naturalistic driving, head mounted displays (HMD) are being considered as a substitute visual cueing system. Recent innovations to virtual reality technologies are encouraging, however, differences between HMDs and more traditional visual displays have not been explored for all types of driving measures. In particular, while existing literature provides insight into the validity of HMDs as a substitute for higher fidelity visual displays in tests of driver behaviour and performance, there is a gap in the literature regarding differences in physiological responses. In the current study, upper body muscle activation and joint angle ranges were compared between an Oculus™ Rift Development Kit 2 HMD and a system of wrap around screens. Twenty-one participants each completed two simulated drives, one per display, in a counterbalanced order. During the simulation, drivers encountered unanticipated pedestrian crossings during which peak surface electromyography, root-mean-square of the surface electromyography signal and joint angles were determined bilaterallyAbstract: As driving performance relies heavily on the interpretation of visual information, driving simulators require a visual display that can effectively communicate the virtual environment to the driver. Most high-fidelity visual displays include an expensive system of high-definition projectors and wraparound screens. To reduce the overall cost of a driving simulator while preserving the generalizability of results to naturalistic driving, head mounted displays (HMD) are being considered as a substitute visual cueing system. Recent innovations to virtual reality technologies are encouraging, however, differences between HMDs and more traditional visual displays have not been explored for all types of driving measures. In particular, while existing literature provides insight into the validity of HMDs as a substitute for higher fidelity visual displays in tests of driver behaviour and performance, there is a gap in the literature regarding differences in physiological responses. In the current study, upper body muscle activation and joint angle ranges were compared between an Oculus™ Rift Development Kit 2 HMD and a system of wrap around screens. Twenty-one participants each completed two simulated drives, one per display, in a counterbalanced order. During the simulation, drivers encountered unanticipated pedestrian crossings during which peak surface electromyography, root-mean-square of the surface electromyography signal and joint angles were determined bilaterally on the upper limbs. No significant differences (p ≤ 0.05) were observed between the Oculus™ Rift HMD and the wrap around screens for all dependent variables with the exception of left joint range of motion in female participants, suggesting that the HMD reduced field of view had a minimal effect on driver kinematics and no effect on muscle activation levels. Upper body bracing was observed during the hazard response time segments characterized by significantly increased muscle activity during hazard response time segments and minimal joint movement. Considering the lack of significant kinematic and muscle activation differences between the two visual inputs, HMD technology for hazard response may provide a suitable alternative to wrap around screens for studying kinematic responses during hazardous driving scenarios. Highlights: Participants responded to a pedestrian hazard using a full-vehicle driving simulator. Compared a virtual reality head mounted display to a system of wrap around screens. No differences in muscle activity and kinematics during upper body bracing responses. Muscle activity and kinematics differed between hazard response and control segments. Evidence for use of head mounted displays given appropriate experimental design. … (more)
- Is Part Of:
- Applied ergonomics. Volume 106(2023)
- Journal:
- Applied ergonomics
- Issue:
- Volume 106(2023)
- Issue Display:
- Volume 106, Issue 2023 (2023)
- Year:
- 2023
- Volume:
- 106
- Issue:
- 2023
- Issue Sort Value:
- 2023-0106-2023-0000
- Page Start:
- Page End:
- Publication Date:
- 2023-01
- Subjects:
- Driving simulation -- Head mounted display -- Wrap around screens -- Hazard reaction -- Surface electromyography -- Kinematics
Human engineering -- Periodicals
620.82 - Journal URLs:
- http://www.sciencedirect.com/science/journal/00036870 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.apergo.2022.103878 ↗
- Languages:
- English
- ISSNs:
- 0003-6870
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 1572.500000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 24180.xml