Effects of wearing a foot orthosis on ankle function in children with idiopathic toe walking during gait. Issue 10 (October 2022)
- Record Type:
- Journal Article
- Title:
- Effects of wearing a foot orthosis on ankle function in children with idiopathic toe walking during gait. Issue 10 (October 2022)
- Main Title:
- Effects of wearing a foot orthosis on ankle function in children with idiopathic toe walking during gait
- Authors:
- Brasiliano, Paolo
Alvini, Martina
Di Stanislao, Eugenio
Vannozzi, Giuseppe
Di Rosa, Giuseppe
Camomilla, Valentina - Abstract:
- Abstract: Background: Idiopathic toe walking (ITW) is a gait deviation characterized by forefoot contact with the ground, possibly enhancing the risk of falling and causing Achilles' tendon shortening and psychological discomfort. Between possible treatments, foot orthosis may limit ITW when worn. With these premises, the effects of a novel foot orthosis (A.Dyn.O.®) on ankle function were analyzed in children with ITW during gait. Methods: Twenty-one children were recruited in the study after ITW diagnosis. At follow-up assessment after a habituation period of at least two weeks, participants walked in barefoot condition and while wearing A.Dyn.O.®. Kinetics and kinematics were derived from a multi-segment foot model using an optoelectronic system. Gait spatiotemporal parameters, ankle kinetic and kinematic and rockers timing were analyzed. Lastly, ITW severity was classified according to Alvarez classification. Differences between conditions were verified with paired t-test. Statistical parametric mapping was used to evaluate differences in the entire kinematic and kinetic waveforms. Findings: Wearing A.Dyn.O.®, step cadence was reduced, step length, stance phase and stride duration increased; physiological heel rocker was present, thus postponing the timing of ankle and forefoot rockers; ankle dorsiflexion angular excursion, range of motion, maximal dorsiflexor and plantarflexor moments together with maximal power absorption and production were all amplified.Abstract: Background: Idiopathic toe walking (ITW) is a gait deviation characterized by forefoot contact with the ground, possibly enhancing the risk of falling and causing Achilles' tendon shortening and psychological discomfort. Between possible treatments, foot orthosis may limit ITW when worn. With these premises, the effects of a novel foot orthosis (A.Dyn.O.®) on ankle function were analyzed in children with ITW during gait. Methods: Twenty-one children were recruited in the study after ITW diagnosis. At follow-up assessment after a habituation period of at least two weeks, participants walked in barefoot condition and while wearing A.Dyn.O.®. Kinetics and kinematics were derived from a multi-segment foot model using an optoelectronic system. Gait spatiotemporal parameters, ankle kinetic and kinematic and rockers timing were analyzed. Lastly, ITW severity was classified according to Alvarez classification. Differences between conditions were verified with paired t-test. Statistical parametric mapping was used to evaluate differences in the entire kinematic and kinetic waveforms. Findings: Wearing A.Dyn.O.®, step cadence was reduced, step length, stance phase and stride duration increased; physiological heel rocker was present, thus postponing the timing of ankle and forefoot rockers; ankle dorsiflexion angular excursion, range of motion, maximal dorsiflexor and plantarflexor moments together with maximal power absorption and production were all amplified. Interpretation: While wearing it, A.Dyn.O.® limited gait deviations typical of ITW and improved ITW severity classification for most of the participants. These findings suggest that the use of A.Dyn.O.® may assist ITW treatment, preventing children from toe walking and thus limiting its side effects. Highlights: Walking barefoot and wearing foot orthosis were analyzed in idiopathic toe walkers. When worn, foot orthosis improves idiopathic toe walking severity classification. Heel-to-toe gait is promoted when using foot orthosis. When worn, foot orthosis improves ankle kinematics, moment, and power. Abstract : Walking; ITW; Multi-segment foot model; Ankle kinematics; Ankle kinetics; Pediatric gait. … (more)
- Is Part Of:
- Heliyon. Volume 8:Issue 10(2022)
- Journal:
- Heliyon
- Issue:
- Volume 8:Issue 10(2022)
- Issue Display:
- Volume 8, Issue 10 (2022)
- Year:
- 2022
- Volume:
- 8
- Issue:
- 10
- Issue Sort Value:
- 2022-0008-0010-0000
- Page Start:
- Page End:
- Publication Date:
- 2022-10
- Subjects:
- Walking -- ITW -- Multi-segment foot model -- Ankle kinematics -- Ankle kinetics -- Pediatric gait
Research -- Periodicals
Medical sciences -- Periodicals
Natural history -- Periodicals
Social sciences -- Periodicals
Earth sciences -- Periodicals
Physical sciences -- Periodicals
507.2 - Journal URLs:
- http://www.sciencedirect.com/science/journal/24058440/ ↗
http://www.sciencedirect.com/ ↗ - DOI:
- 10.1016/j.heliyon.2022.e11021 ↗
- Languages:
- English
- ISSNs:
- 2405-8440
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 24159.xml