Accelerated 3D high-resolution T2-weighted breast MRI with deep learning constrained compressed sensing, comparison with conventional T2-weighted sequence on 3.0 T. Issue 156 (November 2022)
- Record Type:
- Journal Article
- Title:
- Accelerated 3D high-resolution T2-weighted breast MRI with deep learning constrained compressed sensing, comparison with conventional T2-weighted sequence on 3.0 T. Issue 156 (November 2022)
- Main Title:
- Accelerated 3D high-resolution T2-weighted breast MRI with deep learning constrained compressed sensing, comparison with conventional T2-weighted sequence on 3.0 T
- Authors:
- Yang, Fan
Pan, Xuelin
Zhu, Ke
Xiao, Yitian
Yue, Xun
Peng, Pengfei
Zhang, Xiaoyong
Huang, Juan
Chen, Jie
Yuan, Yuan
Sun, Jiayu - Abstract:
- Highlights: In conventional breast T2WI, the thick layer limits the appearance of small lesions, due to the partial volume effect. AI-CS 3D T2WI can be acquired in addition to conventional 2D T2WI in breast imaging. AI-CS 3D T2WI was significantly better than conventional T2WI in qualitative analysis and lesion contrast ratio. Abstract: Purpose: To evaluate the feasibility of isotropic 3D high-resolution T2-weighted imaging (T2WI) MRI sequences and compare the images reconstructed by integrating artificial intelligence-compressed sensing (AI-CS), compressed sensing (CS), and conventional 2D T2WI sequences for quality. Materials and methods: Fifty-two female patients (ages: 26–80 years) with suspected breast cancer were enrolled. They underwent breast MRI examinations using three sequences: conventional T2WI, CS 3D T2WI, and AI-CS 3D T2WI. Image quality, signal-to-noise ratio (SNR), contrast-to-noise ratio, tumor volume, and maximal tumor diameter were compared using the Friedman test. Image quality was scored on a 5-point scale, with 1 indicating nonassessable quality and 5 indicating excellent quality. Tumor volume and maximal tumor diameter were compared based on AI-CS 3D T2WI (slightly high signal), conventional T2WI, and dynamic contrast-enhanced (DCE) sequences. Results: All three T2WI were successfully performed in all patients. 3D CS and AI-CS were significantly better than conventional T2WI in terms of lesion conspicuity and morphology, structural details, overallHighlights: In conventional breast T2WI, the thick layer limits the appearance of small lesions, due to the partial volume effect. AI-CS 3D T2WI can be acquired in addition to conventional 2D T2WI in breast imaging. AI-CS 3D T2WI was significantly better than conventional T2WI in qualitative analysis and lesion contrast ratio. Abstract: Purpose: To evaluate the feasibility of isotropic 3D high-resolution T2-weighted imaging (T2WI) MRI sequences and compare the images reconstructed by integrating artificial intelligence-compressed sensing (AI-CS), compressed sensing (CS), and conventional 2D T2WI sequences for quality. Materials and methods: Fifty-two female patients (ages: 26–80 years) with suspected breast cancer were enrolled. They underwent breast MRI examinations using three sequences: conventional T2WI, CS 3D T2WI, and AI-CS 3D T2WI. Image quality, signal-to-noise ratio (SNR), contrast-to-noise ratio, tumor volume, and maximal tumor diameter were compared using the Friedman test. Image quality was scored on a 5-point scale, with 1 indicating nonassessable quality and 5 indicating excellent quality. Tumor volume and maximal tumor diameter were compared based on AI-CS 3D T2WI (slightly high signal), conventional T2WI, and dynamic contrast-enhanced (DCE) sequences. Results: All three T2WI were successfully performed in all patients. 3D CS and AI-CS were significantly better than conventional T2WI in terms of lesion conspicuity and morphology, structural details, overall image quality, diagnostic information for breast lesions, and breast tissue delineation ( P < 0.001). The SNR of conventional T2WI was significantly higher for 3D T2WI sequences. The contrast-to-noise ratio was significantly higher for AI-CS 3D T2WI than for conventional T2WI sequence. There was no significant difference in tumor volume between DCE (8.08 ± 16.51) and AI-CS 3D T2WI (8.25 ± 16.29) sequences and no significant differences in tumor diameter among DCE, AI-CS 3D T2WI, and conventional T2WI sequences. Conclusion: Isotropic-resolution 3D T2WI sequences can be acquired using AI-CS while maintaining image quality and diagnostic value, which may pave the way for isotropic 3D high-resolution T2WI for clinical application. … (more)
- Is Part Of:
- European journal of radiology. Issue 156(2022)
- Journal:
- European journal of radiology
- Issue:
- Issue 156(2022)
- Issue Display:
- Volume 156, Issue 156 (2022)
- Year:
- 2022
- Volume:
- 156
- Issue:
- 156
- Issue Sort Value:
- 2022-0156-0156-0000
- Page Start:
- Page End:
- Publication Date:
- 2022-11
- Subjects:
- Breast MRI -- Compressed sensing -- Integrating artificial intelligence -- 3D T2WI
Medical radiology -- Periodicals
Radiology -- Periodicals
Radiologie médicale -- Périodiques
Medical radiology
Periodicals
616.075705 - Journal URLs:
- http://www.sciencedirect.com/science/journal/0720048X ↗
http://www.elsevier.com/homepage/elecserv.htt ↗
http://www.clinicalkey.com/dura/browse/journalIssue/0720048X ↗
http://www.clinicalkey.com.au/dura/browse/journalIssue/0720048X ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.ejrad.2022.110562 ↗
- Languages:
- English
- ISSNs:
- 0720-048X
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3829.738050
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 24139.xml