Photon-counting detector CT improves quality of arterial phase abdominal scans: A head-to-head comparison with energy-integrating CT. Issue 156 (November 2022)
- Record Type:
- Journal Article
- Title:
- Photon-counting detector CT improves quality of arterial phase abdominal scans: A head-to-head comparison with energy-integrating CT. Issue 156 (November 2022)
- Main Title:
- Photon-counting detector CT improves quality of arterial phase abdominal scans: A head-to-head comparison with energy-integrating CT
- Authors:
- Graafen, D.
Müller, L.
Halfmann, M.
Düber, C.
Hahn, F.
Yang, Y.
Emrich, T.
Kloeckner, R. - Abstract:
- Abstract: Purpose: Photon-counting detector (PCD)-CT is expected to have a substantial impact on oncologic abdominal imaging. We compared subjective and objective image quality between PCD-CT and conventional energy-integrating detector (EID-)CT arterial phase abdominal scans. Methods: This study included 84 patients undergoing both types of abdominal CT. EID-CT scans were acquired with a tube voltage of 100 kVp. With PCD-CT, acquired with 120-kVp, we reconstructed polychromatic T3D images and virtual monoenergetic images (VMIs) in 10-keV intervals from 40 to 90 keV. Quantitative image analysis included noise and contrast-to-noise ratio (CNR) of hepatic vessels, kidney cortex, and hypervascular liver lesions to liver parenchyma. Three raters used a 5-point Likert scale for qualitative image analysis of image noise and contrast, lesion conspicuity, and overall image quality. Radiation dose exposure (CT dose index) was compared between the two CT types. Results: Mean CT dose index and effective dose were respectively 18 % and 26 % lower with PCD-CT versus EID-CT. Compared with EID-CT, CNRs of kidney cortex and vessel to liver parenchyma were significantly higher in PCD-CT VMIs at energies ≤ 60 keV and in polychromatic T3D images ( p < 0.004). Overall image quality of PCD-CT VMIs at 50 and 60 keV was rated as significantly better ( p < 0.01) than the EID-CT images (inter-reader agreement alpha = 0.80). Lesion conspicuity was significantly better in low-keV VMIs ( p < 0.03)Abstract: Purpose: Photon-counting detector (PCD)-CT is expected to have a substantial impact on oncologic abdominal imaging. We compared subjective and objective image quality between PCD-CT and conventional energy-integrating detector (EID-)CT arterial phase abdominal scans. Methods: This study included 84 patients undergoing both types of abdominal CT. EID-CT scans were acquired with a tube voltage of 100 kVp. With PCD-CT, acquired with 120-kVp, we reconstructed polychromatic T3D images and virtual monoenergetic images (VMIs) in 10-keV intervals from 40 to 90 keV. Quantitative image analysis included noise and contrast-to-noise ratio (CNR) of hepatic vessels, kidney cortex, and hypervascular liver lesions to liver parenchyma. Three raters used a 5-point Likert scale for qualitative image analysis of image noise and contrast, lesion conspicuity, and overall image quality. Radiation dose exposure (CT dose index) was compared between the two CT types. Results: Mean CT dose index and effective dose were respectively 18 % and 26 % lower with PCD-CT versus EID-CT. Compared with EID-CT, CNRs of kidney cortex and vessel to liver parenchyma were significantly higher in PCD-CT VMIs at energies ≤ 60 keV and in polychromatic T3D images ( p < 0.004). Overall image quality of PCD-CT VMIs at 50 and 60 keV was rated as significantly better ( p < 0.01) than the EID-CT images (inter-reader agreement alpha = 0.80). Lesion conspicuity was significantly better in low-keV VMIs ( p < 0.03) and worse in > 70-keV VMIs. Conclusions: With low-keV VMI, PCD-CT yields significantly improved objective and subjective quality of arterial phase oncological imaging compared with EID-CT. This advantage may translate into higher diagnostic confidence and lower radiation dose protocols. … (more)
- Is Part Of:
- European journal of radiology. Issue 156(2022)
- Journal:
- European journal of radiology
- Issue:
- Issue 156(2022)
- Issue Display:
- Volume 156, Issue 156 (2022)
- Year:
- 2022
- Volume:
- 156
- Issue:
- 156
- Issue Sort Value:
- 2022-0156-0156-0000
- Page Start:
- Page End:
- Publication Date:
- 2022-11
- Subjects:
- Abdomen -- Computed tomography -- Photon-counting detector -- Virtual monoenergetic imaging
PCD Photon-counting detector -- EID Energy-integrating detector -- CNR Contrast-to-noise ratio -- CTDI CT dose index -- DLP Dose length product -- VMI Virtual monoenergetic image -- DECT Dual-energy CT -- RD Relative difference -- ROI Region of interest -- SD Standard deviation
Medical radiology -- Periodicals
Radiology -- Periodicals
Radiologie médicale -- Périodiques
Medical radiology
Periodicals
616.075705 - Journal URLs:
- http://www.sciencedirect.com/science/journal/0720048X ↗
http://www.elsevier.com/homepage/elecserv.htt ↗
http://www.clinicalkey.com/dura/browse/journalIssue/0720048X ↗
http://www.clinicalkey.com.au/dura/browse/journalIssue/0720048X ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.ejrad.2022.110514 ↗
- Languages:
- English
- ISSNs:
- 0720-048X
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3829.738050
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 24139.xml