Assessing the risks of haemolysis as an adverse reaction following the transfusion of ABO incompatible plasma-containing components - A scoping review. (November 2022)
- Record Type:
- Journal Article
- Title:
- Assessing the risks of haemolysis as an adverse reaction following the transfusion of ABO incompatible plasma-containing components - A scoping review. (November 2022)
- Main Title:
- Assessing the risks of haemolysis as an adverse reaction following the transfusion of ABO incompatible plasma-containing components - A scoping review
- Authors:
- McCullagh, Josephine
Cardigan, Rebecca
Brunskill, Susan J.
Bullock, Tom
Doree, Carolyn
Estcourt, Lise
Huish, Sian
Sandercock, Josie
Green, Laura - Abstract:
- Abstract: Background The limited supply of universal plasma has resulted in transfusion of ABO incompatible plasma to patients. As the need to implement whole blood transfusion in pre-hospitals setting rises, the lowest cut-off for anti-A/anti-B that does not cause haemolysis remains unknown. In this first scoping review, we aimed to determine the lowest ABO titre and volume reported in the literature to cause haemolysis from ABO incompatible plasma transfusions (plasma, platelets, cryoprecipitate, and whole blood). Methods We searched several databases from inception to April 2022, including all study types. Three independent reviewers extracted and reviewed the data. Primary outcome was the anti-A and anti-B titre (measured by IgM or IgG) that resulted in measurable haemolysis following ABO incompatible plasma transfusion. Results We identified 5681 citations, of which 49 studies were eligible, reporting a total of 62 cases (34 adults, 14 children and 14 did not specify age). The methods for antibody measurement and antibody type (IgG or IgM) varied significantly between studies. Component volumes were poorly reported. The most common component responsible for the haemolysis was apheresis platelets followed by pooled platelets and whole blood. Most haemolytic cases reported were due to anti-A. The lowest anti-A titre reported to cause haemolysis (children and adults) was 32 (IgG), while for anti-B it was 512 (IgG and IgM) for adults, 16, 384 for paediatrics (IgG and IgM)Abstract: Background The limited supply of universal plasma has resulted in transfusion of ABO incompatible plasma to patients. As the need to implement whole blood transfusion in pre-hospitals setting rises, the lowest cut-off for anti-A/anti-B that does not cause haemolysis remains unknown. In this first scoping review, we aimed to determine the lowest ABO titre and volume reported in the literature to cause haemolysis from ABO incompatible plasma transfusions (plasma, platelets, cryoprecipitate, and whole blood). Methods We searched several databases from inception to April 2022, including all study types. Three independent reviewers extracted and reviewed the data. Primary outcome was the anti-A and anti-B titre (measured by IgM or IgG) that resulted in measurable haemolysis following ABO incompatible plasma transfusion. Results We identified 5681 citations, of which 49 studies were eligible, reporting a total of 62 cases (34 adults, 14 children and 14 did not specify age). The methods for antibody measurement and antibody type (IgG or IgM) varied significantly between studies. Component volumes were poorly reported. The most common component responsible for the haemolysis was apheresis platelets followed by pooled platelets and whole blood. Most haemolytic cases reported were due to anti-A. The lowest anti-A titre reported to cause haemolysis (children and adults) was 32 (IgG), while for anti-B it was 512 (IgG and IgM) for adults, 16, 384 for paediatrics (IgG and IgM) and 128 (IgM) in cases where the age was not specified. The lowest reported volume associated with haemolysis were 100 ml (adults) and 15 ml (children). Of the 62 15 (24%) died. Conclusion The lowest titre reported to cause haemolysis was an anti-A of 32. ABO mismatch plasma transfusion may be associated with significant mortality. There is a need to agree/standardise methods for ABO titration measurement internationally for plasma components and agree the lowest anti-A/anti-B titre for transfusing ABO mismatched plasma. … (more)
- Is Part Of:
- Blood reviews. Volume 56(2022)
- Journal:
- Blood reviews
- Issue:
- Volume 56(2022)
- Issue Display:
- Volume 56, Issue 2022 (2022)
- Year:
- 2022
- Volume:
- 56
- Issue:
- 2022
- Issue Sort Value:
- 2022-0056-2022-0000
- Page Start:
- Page End:
- Publication Date:
- 2022-11
- Subjects:
- ABO incompatible -- Plasma -- Platelets -- Titre -- Volume -- Anti-A -- Anti-B -- Haemolysis -- Transfusion
Hematology -- Periodicals
Hematology -- Periodicals
Hématologie -- Périodiques
Hematology
Electronic journals
Periodicals
616.15 - Journal URLs:
- http://www.sciencedirect.com/science/journal/0268960X ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.blre.2022.100989 ↗
- Languages:
- English
- ISSNs:
- 0268-960X
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 2113.038000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 24127.xml