The benefits of adding a defibrillator to cardiac resynchronization therapy – systematic review and meta-analysis. (3rd October 2022)
- Record Type:
- Journal Article
- Title:
- The benefits of adding a defibrillator to cardiac resynchronization therapy – systematic review and meta-analysis. (3rd October 2022)
- Main Title:
- The benefits of adding a defibrillator to cardiac resynchronization therapy – systematic review and meta-analysis
- Authors:
- Veres, B
Gharehdaghi, S
Engh, M
Schwertner, W
Kuthi, L
Merkel, E D
Masszi, R
Fehervari, P
Behon, A
Osztheimer, I
Hegyi, P
Kovacs, A
Zima, E
Kosztin, A
Merkely, B - Abstract:
- Abstract: Background: There is an long-standing debate whether cardiac resynchronisation therapy-defibrillation (CRT-D) is preferred over CRT-pacemaker (CRT-P). No randomised controlled trials have been designed to compare these treatments. However, several observational studies have been performed so far providing controversial results. Methods: PubMed, CENTRAL and Embase until October 2021 were screened for studies comparing CRT-P and CRT-D, focusing on all-cause mortality, cardiovascular mortality, sudden cardiac death, and non-cardiac death. Conference abstracts were excluded. Odds ratio with 95% confidence interval (CI) was calculated, data from the selected studies were pooled using a random effect model (Mantel-Haenszel method, where more than 5 studies with Hartung-Knapp adjustment). τ 2 was estimated by Paule-Mandel method with CI calculated by Q profile method. Statistical heterogeneity was assessed by Cochrane Q test and I 2 test. Results were summarized by Forest and drapery plots. Results: Altogether 20 observational retrospective studies (69, 124 patients) were included (CRT-P: 37, 461, CRT-D: 31, 663). CRT-D was superior to CRT-P regarding all-cause mortality in multivariate analysis (aHR: 0.79; 95% CI: 0.69–0.88; p<0.01). Based on propensity matched studies (25, 040 patients; 12, 520 CRT-P, 12, 520 CRT-D) CRT-D showed significantly better survival compared to CRT-P (HR: 0.83; 95% CI: 0.79–0.87; p<0.001). Three studies (47, 846 patients, CRT-P: 27, 344, CRT-D:Abstract: Background: There is an long-standing debate whether cardiac resynchronisation therapy-defibrillation (CRT-D) is preferred over CRT-pacemaker (CRT-P). No randomised controlled trials have been designed to compare these treatments. However, several observational studies have been performed so far providing controversial results. Methods: PubMed, CENTRAL and Embase until October 2021 were screened for studies comparing CRT-P and CRT-D, focusing on all-cause mortality, cardiovascular mortality, sudden cardiac death, and non-cardiac death. Conference abstracts were excluded. Odds ratio with 95% confidence interval (CI) was calculated, data from the selected studies were pooled using a random effect model (Mantel-Haenszel method, where more than 5 studies with Hartung-Knapp adjustment). τ 2 was estimated by Paule-Mandel method with CI calculated by Q profile method. Statistical heterogeneity was assessed by Cochrane Q test and I 2 test. Results were summarized by Forest and drapery plots. Results: Altogether 20 observational retrospective studies (69, 124 patients) were included (CRT-P: 37, 461, CRT-D: 31, 663). CRT-D was superior to CRT-P regarding all-cause mortality in multivariate analysis (aHR: 0.79; 95% CI: 0.69–0.88; p<0.01). Based on propensity matched studies (25, 040 patients; 12, 520 CRT-P, 12, 520 CRT-D) CRT-D showed significantly better survival compared to CRT-P (HR: 0.83; 95% CI: 0.79–0.87; p<0.001). Three studies (47, 846 patients, CRT-P: 27, 344, CRT-D: 20, 502) compared cardiovascular mortality between CRT-D and CRT-P. Univariate analysis showed a significantly lower rate of cardiovascular mortality in patients implanted with a CRT-D device compared to patients with a CRT-P device (HR: 0.61; 95% CI: 0.50–0.73; p=0.002). Three studies (4, 623 patients. CRT-P: 2, 518, CRT-D: 2, 105) reported on heart failure death, where CRT-D was associated with decreased heart failure mortality compared to CRT-P (HR: 0.68; 95% CI: 0.41–0.95; p=0.008). Five studies (6, 434 patients. CRT-P: 3, 475, CRT-D: 2, 959) were analyzed for sudden cardiac death, CRT-D was superior in univariate analysis (HR: 0.33; 95% CI: 0.28–0.89; p=0.03). Three studies (48, 770 patients, CRT-P: 28, 398, CRT-D: 20, 372) reported on non-cardiac death, CRT-D showed significantly better survival than CRT-P (HR: 0.58; 95% CI: 0.55–0.60; p<0.001). Conclusion: Our meta-analysis demonstrated that patients with CRT-D had a lower risk of all-cause mortality compared to CRT-P based on those studies that used multivariate analysis and propensity score matching. Univariate analysis showed a significantly lower rate of cardiovascular heart failure mortality, sudden cardiac death, and non-cardiac death in patients implanted with a CRT-D device compared to patients with a CRT-P. However, due to the heterogeneity of the articles coming from the selection bias of patients for CRT-D/CRT-P implantation, this question requires further analysis. Funding Acknowledgement: Type of funding sources: Other. Main funding source(s): The research presented here, carried out by Semmelweis University was supported by Semmelweis 250+ Excellence Scholarship (EFOP-3.6.3-VEKOP-16-2017-00009)as well as the Centre for Translational Medicine, Semmelweis University. This work was financed by the Thematic Excellence Programme (2020-4.1.1.-TKP2020) of the Ministry for Innovation and Technology in Hungary, within the framework of the Therapeutic Development and Bioimaging thematic programmes of the Semmelweis University. - I agree that this information can be anonymised and then used for statistical purposes only … (more)
- Is Part Of:
- European heart journal. Volume 43(2022)Supplement 2
- Journal:
- European heart journal
- Issue:
- Volume 43(2022)Supplement 2
- Issue Display:
- Volume 43, Issue 2 (2022)
- Year:
- 2022
- Volume:
- 43
- Issue:
- 2
- Issue Sort Value:
- 2022-0043-0002-0000
- Page Start:
- Page End:
- Publication Date:
- 2022-10-03
- Subjects:
- Cardiology -- Periodicals
Heart -- Diseases -- Periodicals
616.12005 - Journal URLs:
- http://eurheartj.oxfordjournals.org/ ↗
http://ukcatalogue.oup.com/ ↗ - DOI:
- 10.1093/eurheartj/ehac544.735 ↗
- Languages:
- English
- ISSNs:
- 0195-668X
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3829.717500
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 24109.xml