Remote ECG monitoring to reduce complications following transcatheter aortic valve implantations: the Redirect TAVI study . Issue 9 (14th June 2022)
- Record Type:
- Journal Article
- Title:
- Remote ECG monitoring to reduce complications following transcatheter aortic valve implantations: the Redirect TAVI study . Issue 9 (14th June 2022)
- Main Title:
- Remote ECG monitoring to reduce complications following transcatheter aortic valve implantations: the Redirect TAVI study
- Authors:
- Natarajan, Madhu Kailash
Sheth, Tej Narendra
Wijeysundera, Harindra Channa
Chavarria, Jorge
Rodes-Cabau, Josep
Velianou, James Louis
Radhakrishnan, Sam
Newman, Toni
Smith, Amanda
Wong, Jorge Alfredo
Schwalm, Jon David
Duong, Monica
Mian, Rajibul Islam
Bishop, Marsella Giuliana
Healey, Jeffrey Sean - Abstract:
- Abstract: Aims: The optimal strategy of monitoring for conduction disturbances in patients undergoing transcatheter aortic valve implantation (TAVI) is uncertain. We evaluated a pre- and post-TAVI remote ambulatory cardiac monitoring (rACM) strategy for identification of conduction disturbances and to reduce unplanned pre-discharge post-TAVI permanent pacemaker implantation (PPMI). Methods and results: REdireCT TAVI (NCT0381820) was a prospective cohort study of patients referred for outpatient TAVI. Patients with prior PPMI were excluded. Remote ambulatory cardiac monitoring consisted of 2 weeks of continuous electrocardiogram (ECG) monitoring (Pocket-ECG TM ) both before and after TAVI. Compliance to monitoring, frequency of notifications, unplanned PPMI post-TAVI, and length of hospitalization were measured. Between June 2018 and March 2020, in 192 undergoing TAVI (mean age: 81.8 years; female sex 46%; balloon-expandable valve 95.3%), compliance to rACM was 91.7% pre-TAVI (mean duration: 12.8 days), and 87.5% post-TAVI (mean duration: 12.9 days). There were 24 (12.5%) rACM notifications (13 pre-TAVI; 11 post-TAVI) resulting in 14 (7.3%) planned PPMI: seven pre-TAVI [due to sinus pauses n = 2 or atrio-ventricular block (AVB) n = 5] and seven post-TAVI [due to sinus pauses n = 1 or AVB n = 5 or ventricular tachycardia (VT) n = 1]. In addition, nine (4.7%) patients received pre-TAVI PPMI due to high-risk baseline ECG (right bundle branch block with hemi-block orAbstract: Aims: The optimal strategy of monitoring for conduction disturbances in patients undergoing transcatheter aortic valve implantation (TAVI) is uncertain. We evaluated a pre- and post-TAVI remote ambulatory cardiac monitoring (rACM) strategy for identification of conduction disturbances and to reduce unplanned pre-discharge post-TAVI permanent pacemaker implantation (PPMI). Methods and results: REdireCT TAVI (NCT0381820) was a prospective cohort study of patients referred for outpatient TAVI. Patients with prior PPMI were excluded. Remote ambulatory cardiac monitoring consisted of 2 weeks of continuous electrocardiogram (ECG) monitoring (Pocket-ECG TM ) both before and after TAVI. Compliance to monitoring, frequency of notifications, unplanned PPMI post-TAVI, and length of hospitalization were measured. Between June 2018 and March 2020, in 192 undergoing TAVI (mean age: 81.8 years; female sex 46%; balloon-expandable valve 95.3%), compliance to rACM was 91.7% pre-TAVI (mean duration: 12.8 days), and 87.5% post-TAVI (mean duration: 12.9 days). There were 24 (12.5%) rACM notifications (13 pre-TAVI; 11 post-TAVI) resulting in 14 (7.3%) planned PPMI: seven pre-TAVI [due to sinus pauses n = 2 or atrio-ventricular block (AVB) n = 5] and seven post-TAVI [due to sinus pauses n = 1 or AVB n = 5 or ventricular tachycardia (VT) n = 1]. In addition, nine (4.7%) patients received pre-TAVI PPMI due to high-risk baseline ECG (right bundle branch block with hemi-block or prolonged PR interval). Unplanned PPMI post-TAVI during index hospitalization occurred in six (3.1%) patients due to AVB and in one patient readmitted with AVB. The median length of stay post-TAVI was 1 day. Conclusion: A strategy of routine rACM was feasible and frequently led to PPMI. Our approach of 2-week rACM both pre- and post-TAVI achieves both high patient compliance and sufficient surveillance. Clinical trial registration: Clinical Trial Registration: https://clinicaltrials.gov/ct2/show/NCT03810820 … (more)
- Is Part Of:
- Europace. Volume 24:Issue 9(2022)
- Journal:
- Europace
- Issue:
- Volume 24:Issue 9(2022)
- Issue Display:
- Volume 24, Issue 9 (2022)
- Year:
- 2022
- Volume:
- 24
- Issue:
- 9
- Issue Sort Value:
- 2022-0024-0009-0000
- Page Start:
- 1475
- Page End:
- 1483
- Publication Date:
- 2022-06-14
- Subjects:
- Transcatheter aortic valve implantation -- Heart block -- Bradyarrhythmia -- Permanent pacemaker -- Remote ambulatory cardiac monitoring
Arrhythmia -- Treatment -- Periodicals
Cardiac pacing -- Periodicals
Catheter ablation -- Periodicals
Heart -- Physiology -- Periodicals
Electrophysiology -- Periodicals
617.4120645 - Journal URLs:
- http://europace.oxfordjournals.org/ ↗
http://ukcatalogue.oup.com/ ↗ - DOI:
- 10.1093/europace/euac042 ↗
- Languages:
- English
- ISSNs:
- 1099-5129
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3829.340450
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File: