Position sensitive detectors in proton therapy: online monitoring of the beam position. (1st October 2022)
- Record Type:
- Journal Article
- Title:
- Position sensitive detectors in proton therapy: online monitoring of the beam position. (1st October 2022)
- Main Title:
- Position sensitive detectors in proton therapy: online monitoring of the beam position
- Authors:
- Schaefer, R.
Actis, O.
Koenig, S.
Eichin, M.
Weber, D.C. - Abstract:
- Abstract: Spot-scanning is a highly dynamic treatment method in proton therapy, tailored to each tumor shape individually. By superimposing many single spots in all three spatial axes, a prescribed dose is applied to the tumor volume. To minimize dose inhomogeneity across this volume, tight constraints on the beam position accuracy apply: for a dose inhomogeneity below 1%, a longitudinal beam position accuracy of the order of 1 mm is necessary, whereas in the lateral plane, the accuracy needs to be roughly one order of magnitude better. Longitudinal position control is achieved through selecting the beam energy; laterally, this is achieved by two sweeper magnets, allowing position changes within milliseconds. Such dynamics and accuracy constraints require an online measurement of the beam position to enable and maintain high treatment quality assurance. Gantry 2 at the Center for Proton Therapy at PSI operates a plane parallel strip ionization chamber for this purpose as the final beamline element before the patient. The foil-based detector design is optimized for an in-situ placement in the beam axis and keeps beam disturbance at a minimum. A strip pitch of 2 mm allows to reconstruct the Gaussian shape beam profile with the desired accuracy. These beam profiles are analyzed (and verified) during a treatment on a spot-by-spot basis, before the next spot is applied, introducing a dead time after every spot. Applying 50, 000 spots in a treatment introduces the challenge toAbstract: Spot-scanning is a highly dynamic treatment method in proton therapy, tailored to each tumor shape individually. By superimposing many single spots in all three spatial axes, a prescribed dose is applied to the tumor volume. To minimize dose inhomogeneity across this volume, tight constraints on the beam position accuracy apply: for a dose inhomogeneity below 1%, a longitudinal beam position accuracy of the order of 1 mm is necessary, whereas in the lateral plane, the accuracy needs to be roughly one order of magnitude better. Longitudinal position control is achieved through selecting the beam energy; laterally, this is achieved by two sweeper magnets, allowing position changes within milliseconds. Such dynamics and accuracy constraints require an online measurement of the beam position to enable and maintain high treatment quality assurance. Gantry 2 at the Center for Proton Therapy at PSI operates a plane parallel strip ionization chamber for this purpose as the final beamline element before the patient. The foil-based detector design is optimized for an in-situ placement in the beam axis and keeps beam disturbance at a minimum. A strip pitch of 2 mm allows to reconstruct the Gaussian shape beam profile with the desired accuracy. These beam profiles are analyzed (and verified) during a treatment on a spot-by-spot basis, before the next spot is applied, introducing a dead time after every spot. Applying 50, 000 spots in a treatment introduces the challenge to data acquisition and — processing in terms of keeping treatment times reasonable. Data pileup and long dead times are mitigated by optimized front-end electronics and early-stage data processing, without compromising data quality and the accuracy of the measured beam position. … (more)
- Is Part Of:
- Journal of instrumentation. Volume 17:Number 10(2022)
- Journal:
- Journal of instrumentation
- Issue:
- Volume 17:Number 10(2022)
- Issue Display:
- Volume 17, Issue 10 (2022)
- Year:
- 2022
- Volume:
- 17
- Issue:
- 10
- Issue Sort Value:
- 2022-0017-0010-0000
- Page Start:
- Page End:
- Publication Date:
- 2022-10-01
- Subjects:
- Beam-line instrumentation (beam position and profile monitors, beam-intensity monitors, bunch length monitors) -- Gaseous detectors -- Instrumentation for particle-beam therapy -- Control and monitor systems online
Scientific apparatus and instruments -- Periodicals
502.84 - Journal URLs:
- http://iopscience.iop.org/1748-0221 ↗
http://ioppublishing.org/ ↗ - DOI:
- 10.1088/1748-0221/17/10/C10017 ↗
- Languages:
- English
- ISSNs:
- 1748-0221
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 24072.xml