The influence of the reference electrode location on the M−wave characteristics in the quadriceps. (October 2022)
- Record Type:
- Journal Article
- Title:
- The influence of the reference electrode location on the M−wave characteristics in the quadriceps. (October 2022)
- Main Title:
- The influence of the reference electrode location on the M−wave characteristics in the quadriceps
- Authors:
- Rodriguez-Falces, Javier
Etxaleku, Saioa
Setuain, Igor
Malanda, Armando
Navallas, Javier - Abstract:
- Abstract: Introduction: In the compound muscle action potential (M wave) recorded using the belly-tendon configuration, the contribution of the tendon electrode is assumed to be negligible compared to the belly electrode. We tested this assumption by placing the reference electrode at a distant (contralateral) site, which allowed separate recording of the belly and tendon contributions. Methods: M waves were recorded at multiple selected sites over the right quadriceps heads and lower leg using two different locations for the reference electrode: the ipsilateral (right) and contralateral (left) patellar tendon. The general parameters of the M wave (amplitude, area, duration, latency, and frequency) were measured. Results: (1) The tendon potential had a small amplitude (<30%) compared to the belly potential; (2) Changing the reference electrode from the ipsilateral to the contralateral patella produced moderate changes in the M wave recorded over the innervation zone, these changes affecting significantly the amplitude of the M−wave second phase (p = 0.006); (3) Using the contralateral reference system allowed recording of short-latency components occurring immediately after the stimulus artefact, which had the same latency and amplitude (p = 0.18 and 0.25, respectively) at all recording sites over the leg. Conclusions: The potential recorded at the "tendon" site after femoral nerve stimulation is small (compared to the belly potential), but not negligible, and makes aAbstract: Introduction: In the compound muscle action potential (M wave) recorded using the belly-tendon configuration, the contribution of the tendon electrode is assumed to be negligible compared to the belly electrode. We tested this assumption by placing the reference electrode at a distant (contralateral) site, which allowed separate recording of the belly and tendon contributions. Methods: M waves were recorded at multiple selected sites over the right quadriceps heads and lower leg using two different locations for the reference electrode: the ipsilateral (right) and contralateral (left) patellar tendon. The general parameters of the M wave (amplitude, area, duration, latency, and frequency) were measured. Results: (1) The tendon potential had a small amplitude (<30%) compared to the belly potential; (2) Changing the reference electrode from the ipsilateral to the contralateral patella produced moderate changes in the M wave recorded over the innervation zone, these changes affecting significantly the amplitude of the M−wave second phase (p = 0.006); (3) Using the contralateral reference system allowed recording of short-latency components occurring immediately after the stimulus artefact, which had the same latency and amplitude (p = 0.18 and 0.25, respectively) at all recording sites over the leg. Conclusions: The potential recorded at the "tendon" site after femoral nerve stimulation is small (compared to the belly potential), but not negligible, and makes a significant contribution to the second phase of belly-tendon M wave. Adopting a distant (contralateral) reference allowed recording of far-field components that may aid in the understanding of the electrical formation of the M wave. … (more)
- Is Part Of:
- Journal of electromyography and kinesiology. Volume 66(2022)
- Journal:
- Journal of electromyography and kinesiology
- Issue:
- Volume 66(2022)
- Issue Display:
- Volume 66, Issue 2022 (2022)
- Year:
- 2022
- Volume:
- 66
- Issue:
- 2022
- Issue Sort Value:
- 2022-0066-2022-0000
- Page Start:
- Page End:
- Publication Date:
- 2022-10
- Subjects:
- Belly-tendon configuration -- Reference electrode -- Active electrode -- Compound muscle action potential -- M wave -- Volume conduction -- Far-field potentials
Electromyography -- Periodicals
Kinesiology -- Periodicals
Electromyography -- Periodicals
Movement -- physiology -- Periodicals
Muscles -- physiology -- Periodicals
Électromyographie -- Périodiques
Cinésiologie -- Périodiques
Electromyography
Kinesiology
Electronic journals
Periodicals
616.740757 - Journal URLs:
- http://www.sciencedirect.com/science/journal/10506411 ↗
http://www.clinicalkey.com/dura/browse/journalIssue/10506411 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.jelekin.2022.102681 ↗
- Languages:
- English
- ISSNs:
- 1050-6411
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4974.855000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 24049.xml