A systematic review and meta-analysis of the Derivo Embolization Device: a novel surface-modified flow diverter for intracranial aneurysm treatment. (1st March 2022)
- Record Type:
- Journal Article
- Title:
- A systematic review and meta-analysis of the Derivo Embolization Device: a novel surface-modified flow diverter for intracranial aneurysm treatment. (1st March 2022)
- Main Title:
- A systematic review and meta-analysis of the Derivo Embolization Device: a novel surface-modified flow diverter for intracranial aneurysm treatment
- Authors:
- Monteiro, Andre
Burke, Samantha M
Baig, Ammad A
Khan, Slah
Cappuzzo, Justin M
Waqas, Muhammad
Dietrich, Joseph E
Levy, Elad I
Siddiqui, Adnan H - Abstract:
- Abstract : Background: Surface-modified flow diverters (FDs) designed to reduce thrombogenicity represent the next frontier for intracranial aneurysm treatment. The Derivo Embolization Device (DED) is a novel FD with titanium oxide and titanium oxynitride finishing of the struts. We performed a systematic review of pertinent literature, aiming to evaluate the device's effectiveness and safety. Methods: A literature search of PubMed, Embase, and MEDLINE was conducted following Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines. Results: Five studies comprising 481 aneurysms were included. These studies were conducted in Turkey, Brazil, Germany, Poland, and Italy; two were prospective and three were retrospective. Twenty-six aneurysms (5.4%) were ruptured. The antiplatelet regimens were heterogeneous, but dual antiplatelet therapy was administered preprocedurally in all studies and maintained for 3–12 months before a switch to single antiplatelet therapy. The rate of periprocedural ischemic and hemorrhagic complications was 4.9% (95% CI 2.9% to 7%). Adjunctive coiling was used in 25.6% (95% CI 11.4% to 39.8%) of aneurysms. The complete angiographic occlusion rate was 81.4% (95% CI 71.3% to 91.5%), mortality rate was 2.1% (95% CI 0.4% to 3.9%), with follow-up ranging from 9 to 18 months. Delayed aneurysm rupture was reported in one patient. Conclusions: The DED has been increasingly used in other countries. We identified low rates ofAbstract : Background: Surface-modified flow diverters (FDs) designed to reduce thrombogenicity represent the next frontier for intracranial aneurysm treatment. The Derivo Embolization Device (DED) is a novel FD with titanium oxide and titanium oxynitride finishing of the struts. We performed a systematic review of pertinent literature, aiming to evaluate the device's effectiveness and safety. Methods: A literature search of PubMed, Embase, and MEDLINE was conducted following Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines. Results: Five studies comprising 481 aneurysms were included. These studies were conducted in Turkey, Brazil, Germany, Poland, and Italy; two were prospective and three were retrospective. Twenty-six aneurysms (5.4%) were ruptured. The antiplatelet regimens were heterogeneous, but dual antiplatelet therapy was administered preprocedurally in all studies and maintained for 3–12 months before a switch to single antiplatelet therapy. The rate of periprocedural ischemic and hemorrhagic complications was 4.9% (95% CI 2.9% to 7%). Adjunctive coiling was used in 25.6% (95% CI 11.4% to 39.8%) of aneurysms. The complete angiographic occlusion rate was 81.4% (95% CI 71.3% to 91.5%), mortality rate was 2.1% (95% CI 0.4% to 3.9%), with follow-up ranging from 9 to 18 months. Delayed aneurysm rupture was reported in one patient. Conclusions: The DED has been increasingly used in other countries. We identified low rates of periprocedural complications and mortality and a high rate of complete occlusion. … (more)
- Is Part Of:
- Journal of neurointerventional surgery. Volume 14:Number 11(2022)
- Journal:
- Journal of neurointerventional surgery
- Issue:
- Volume 14:Number 11(2022)
- Issue Display:
- Volume 14, Issue 11 (2022)
- Year:
- 2022
- Volume:
- 14
- Issue:
- 11
- Issue Sort Value:
- 2022-0014-0011-0000
- Page Start:
- 1125
- Page End:
- 1129
- Publication Date:
- 2022-03-01
- Subjects:
- aneurysm -- device -- flow diverter -- technology
Nervous system -- Surgery -- Periodicals
Cerebrovascular disease -- Surgery -- Periodicals
617.48 - Journal URLs:
- http://www.bmj.com/archive ↗
http://jnis.bmj.com/ ↗ - DOI:
- 10.1136/neurintsurg-2021-018390 ↗
- Languages:
- English
- ISSNs:
- 1759-8478
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 24053.xml