An iPRES‐W Coil Array for Simultaneous Imaging and Wireless Localized B0 Shimming of the Cervical Spinal Cord. Issue 2 (25th April 2022)
- Record Type:
- Journal Article
- Title:
- An iPRES‐W Coil Array for Simultaneous Imaging and Wireless Localized B0 Shimming of the Cervical Spinal Cord. Issue 2 (25th April 2022)
- Main Title:
- An iPRES‐W Coil Array for Simultaneous Imaging and Wireless Localized B0 Shimming of the Cervical Spinal Cord
- Authors:
- Cuthbertson, Jonathan D.
Truong, Trong‐Kha
Stormont, Robert
Robb, Fraser
Song, Allen W.
Darnell, Dean - Abstract:
- Abstract : Purpose: To develop a wireless integrated parallel reception, excitation, and shimming (iPRES‐W) coil array for simultaneous imaging and wireless localized B 0 shimming, and to demonstrate its ability to correct for distortions in DTI of the spinal cord in vivo. Methods: A 4‐channel coil array was modified to allow an RF current at the Larmor frequency and a direct current to flow on each coil element, enabling imaging and localized B 0 shimming, respectively. One coil element was further modified to allow additional RF currents within a wireless communication band to flow on it to wirelessly control the direct currents for shimming, which were supplied from a battery pack within the scanner bore. The RF signals for imaging were transferred via conventional wired connections. Experiments were conducted to evaluate the RF, B 0 shimming, and wireless performance of this coil design. Results: The coil modifications did not degrade the SNR. Wireless localized B 0 shimming with the iPRES‐W coil array substantially reduced the B 0 RMSE (−57.5% on average) and DTI distortions in the spinal cord. The antenna radiation efficiency, antenna gain pattern, and battery power consumption of an iPRES‐W coil measured in an anechoic chamber were minimally impacted by the introduction of a saline phantom representing tissue. Conclusion: The iPRES‐W coil array can perform imaging and wireless localized B 0 shimming of the spinal cord with no SNR degradation, with minimal change inAbstract : Purpose: To develop a wireless integrated parallel reception, excitation, and shimming (iPRES‐W) coil array for simultaneous imaging and wireless localized B 0 shimming, and to demonstrate its ability to correct for distortions in DTI of the spinal cord in vivo. Methods: A 4‐channel coil array was modified to allow an RF current at the Larmor frequency and a direct current to flow on each coil element, enabling imaging and localized B 0 shimming, respectively. One coil element was further modified to allow additional RF currents within a wireless communication band to flow on it to wirelessly control the direct currents for shimming, which were supplied from a battery pack within the scanner bore. The RF signals for imaging were transferred via conventional wired connections. Experiments were conducted to evaluate the RF, B 0 shimming, and wireless performance of this coil design. Results: The coil modifications did not degrade the SNR. Wireless localized B 0 shimming with the iPRES‐W coil array substantially reduced the B 0 RMSE (−57.5% on average) and DTI distortions in the spinal cord. The antenna radiation efficiency, antenna gain pattern, and battery power consumption of an iPRES‐W coil measured in an anechoic chamber were minimally impacted by the introduction of a saline phantom representing tissue. Conclusion: The iPRES‐W coil array can perform imaging and wireless localized B 0 shimming of the spinal cord with no SNR degradation, with minimal change in wireless performance and without any scanner modifications or additional antenna systems within the scanner bore. … (more)
- Is Part Of:
- Magnetic resonance in medicine. Volume 88:Issue 2(2022)
- Journal:
- Magnetic resonance in medicine
- Issue:
- Volume 88:Issue 2(2022)
- Issue Display:
- Volume 88, Issue 2 (2022)
- Year:
- 2022
- Volume:
- 88
- Issue:
- 2
- Issue Sort Value:
- 2022-0088-0002-0000
- Page Start:
- 1002
- Page End:
- 1014
- Publication Date:
- 2022-04-25
- Subjects:
- B0 shimming -- integrated RF/wireless coil -- iPRES -- spinal cord -- WiFi
Nuclear magnetic resonance -- Periodicals
Electron paramagnetic resonance -- Periodicals
616.07548 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)1522-2594 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/mrm.29257 ↗
- Languages:
- English
- ISSNs:
- 0740-3194
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5337.798000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 24056.xml