In situ Ti isotopic analysis by femtosecond laser ablation MC-ICP-MS. Issue 10 (9th September 2022)
- Record Type:
- Journal Article
- Title:
- In situ Ti isotopic analysis by femtosecond laser ablation MC-ICP-MS. Issue 10 (9th September 2022)
- Main Title:
- In situ Ti isotopic analysis by femtosecond laser ablation MC-ICP-MS
- Authors:
- Huang, Chao
Wang, Hao
Xie, Liewen
Nie, Nicole X.
Yang, Yueheng
Zhao, Xinmiao
Li, Jin
Tian, Heng-Ci
Wu, Shitou
Xu, Lei
Yang, Jinhui - Abstract:
- Abstract : Titanium isotopes are emerging as a power tool for studying magmatic processes on the Earth and other planets. In our work, a novel and robust method for in situ Ti isotopic analysis of titanium-bearing minerals was presented by fs-LA-MC-ICP-MS. Abstract : Titanium (Ti) isotopes are emerging as a power tool for studying magmatic processes on the Earth and other planets. Pioneering studies carried out bulk-rock Ti isotopic measurements by conventional solution nebulization multi-collector inductively coupled plasma mass spectrometry (SN-MC-ICP-MS) and in situ Ti isotopic analysis via secondary ionization mass spectrometry (SIMS), which sacrificed spatial resolution and had relatively low analytical precision, respectively. In this work, a novel and robust method for in situ Ti isotopic analysis of titanium-bearing minerals ( i.e., rutile and ilmenite) was presented, based on a femtosecond laser ablation multi-collector inductively coupled plasma mass spectrometer (fs-LA-MC-ICP-MS). Very stable isotopic signals can be ensured after careful optimization of the parameters of fs-LA ( e.g., fluence, spot size, and frequency), and thus a high analytical precision has been obtained for Alfa-Ti (an ultrapure Ti metal rod) under a high spatial resolution of spot diameter = 30 μm. The within run and external reproducibility for δ 49/47 Ti ( 49 Ti/ 47 Ti isotopic ratio, reported as δ 49/47 Ti notation, in parts in 10 3 ) measurement on Alfa-Ti are 0.05‰ (2SE, internalAbstract : Titanium isotopes are emerging as a power tool for studying magmatic processes on the Earth and other planets. In our work, a novel and robust method for in situ Ti isotopic analysis of titanium-bearing minerals was presented by fs-LA-MC-ICP-MS. Abstract : Titanium (Ti) isotopes are emerging as a power tool for studying magmatic processes on the Earth and other planets. Pioneering studies carried out bulk-rock Ti isotopic measurements by conventional solution nebulization multi-collector inductively coupled plasma mass spectrometry (SN-MC-ICP-MS) and in situ Ti isotopic analysis via secondary ionization mass spectrometry (SIMS), which sacrificed spatial resolution and had relatively low analytical precision, respectively. In this work, a novel and robust method for in situ Ti isotopic analysis of titanium-bearing minerals ( i.e., rutile and ilmenite) was presented, based on a femtosecond laser ablation multi-collector inductively coupled plasma mass spectrometer (fs-LA-MC-ICP-MS). Very stable isotopic signals can be ensured after careful optimization of the parameters of fs-LA ( e.g., fluence, spot size, and frequency), and thus a high analytical precision has been obtained for Alfa-Ti (an ultrapure Ti metal rod) under a high spatial resolution of spot diameter = 30 μm. The within run and external reproducibility for δ 49/47 Ti ( 49 Ti/ 47 Ti isotopic ratio, reported as δ 49/47 Ti notation, in parts in 10 3 ) measurement on Alfa-Ti are 0.05‰ (2SE, internal precision of within-spot analysis) and 0.07‰ (2SD, external reproducibility of spot-to-spot analysis), respectively. A series of titanium-bearing minerals, including five potential rutile U–Pb chronological standards and four potential ilmenite Fe isotope standards, were assessed for Ti isotopic homogeneity on a 30 μm-scale and precision of the measurement. The most homogeneous minerals were subsequently used to comprehensively evaluate the analytical accuracy and potential matrix effect. Our results show that in situ Ti isotopic analysis is susceptible to matrix effects when using fs-LA and accurate δ 49/47 TiOL-Ti values (calibrated against the OL-Ti reference material developed in the Origins Laboratory of the University of Chicago) can be obtained when a matrix-matched reference material is used as a bracketing standard. Therefore, well characterized matrix-matched reference materials are necessary for in situ Ti isotopic analysis. KNW rutile and PZH12-15 ilmenite characterized in this study show potential as suitable reference materials for micro-beam Ti isotopic analysis. … (more)
- Is Part Of:
- Journal of analytical atomic spectrometry. Volume 37:Issue 10(2022)
- Journal:
- Journal of analytical atomic spectrometry
- Issue:
- Volume 37:Issue 10(2022)
- Issue Display:
- Volume 37, Issue 10 (2022)
- Year:
- 2022
- Volume:
- 37
- Issue:
- 10
- Issue Sort Value:
- 2022-0037-0010-0000
- Page Start:
- 2165
- Page End:
- 2175
- Publication Date:
- 2022-09-09
- Subjects:
- Atomic spectra -- Periodicals
Atomic absorption spectroscopy -- Periodicals
543.0858 - Journal URLs:
- http://pubs.rsc.org/en/journals/journalissues/ja#!recentarticles&adv ↗
http://www.rsc.org/ ↗ - DOI:
- 10.1039/d2ja00189f ↗
- Languages:
- English
- ISSNs:
- 0267-9477
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4928.200000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 24044.xml