Optimized 64‐channel array configurations for accelerated simultaneous multislice acquisitions in 3T cardiac MRI. Issue 4 (24th May 2021)
- Record Type:
- Journal Article
- Title:
- Optimized 64‐channel array configurations for accelerated simultaneous multislice acquisitions in 3T cardiac MRI. Issue 4 (24th May 2021)
- Main Title:
- Optimized 64‐channel array configurations for accelerated simultaneous multislice acquisitions in 3T cardiac MRI
- Authors:
- Etzel, Robin
Mekkaoui, Choukri
Ivshina, Ekaterina S.
Reese, Timothy G.
Sosnovik, David E.
Hansen, Sam‐Luca J. D.
Ghotra, Anpreet
Kutscha, Nicolas
Chemlali, Chaimaa
Wald, Lawrence L.
Mahnken, Andreas H.
Keil, Boris - Abstract:
- Abstract : Purpose: Three 64‐channel cardiac coils with different detector array configurations were designed and constructed to evaluate acceleration capabilities in simultaneous multislice (SMS) imaging for 3T cardiac MRI. Methods: Three 64‐channel coil array configurations obtained from a simulation‐guided design approach were constructed and systematically evaluated regarding their encoding capabilities for accelerated SMS cardiac acquisitions at 3T. Array configuration AUni‐sized consists of uniformly distributed equally sized loops in an overlapped arrangement, BGapped uses a gapped array design with symmetrically distributed equally sized loops, and CDense has non‐uniform loop density and size, where smaller elements were centered over the heart and larger elements were placed surrounding the target region. To isolate the anatomic variation from differences in the coil configurations, all three array coils were built with identical semi‐adjustable housing segments. The arrays' performance was compared using bench‐level measurements and imaging performance tests, including signal‐to‐noise ratio (SNR) maps, array element noise correlation, and SMS acceleration capabilities. Additionally, all cardiac array coils were evaluated on a healthy volunteer. Results: The array configuration CDense with the non‐uniformly distributed loop density showed the best overall cardiac imaging performance in both SNR and SMS encoding power, when compared to the other constructed arrays.Abstract : Purpose: Three 64‐channel cardiac coils with different detector array configurations were designed and constructed to evaluate acceleration capabilities in simultaneous multislice (SMS) imaging for 3T cardiac MRI. Methods: Three 64‐channel coil array configurations obtained from a simulation‐guided design approach were constructed and systematically evaluated regarding their encoding capabilities for accelerated SMS cardiac acquisitions at 3T. Array configuration AUni‐sized consists of uniformly distributed equally sized loops in an overlapped arrangement, BGapped uses a gapped array design with symmetrically distributed equally sized loops, and CDense has non‐uniform loop density and size, where smaller elements were centered over the heart and larger elements were placed surrounding the target region. To isolate the anatomic variation from differences in the coil configurations, all three array coils were built with identical semi‐adjustable housing segments. The arrays' performance was compared using bench‐level measurements and imaging performance tests, including signal‐to‐noise ratio (SNR) maps, array element noise correlation, and SMS acceleration capabilities. Additionally, all cardiac array coils were evaluated on a healthy volunteer. Results: The array configuration CDense with the non‐uniformly distributed loop density showed the best overall cardiac imaging performance in both SNR and SMS encoding power, when compared to the other constructed arrays. The diffusion weighted cardiac acquisitions on a healthy volunteer support the favorable accelerated SNR performance of this array configuration. Conclusion: Our results indicate that optimized highly parallel cardiac arrays, such as the 64‐channel coil with a non‐uniform loop size and density improve highly accelerated SMS cardiac MRI in comparison to symmetrically distributed loop array designs. … (more)
- Is Part Of:
- Magnetic resonance in medicine. Volume 86:Issue 4(2021)
- Journal:
- Magnetic resonance in medicine
- Issue:
- Volume 86:Issue 4(2021)
- Issue Display:
- Volume 86, Issue 4 (2021)
- Year:
- 2021
- Volume:
- 86
- Issue:
- 4
- Issue Sort Value:
- 2021-0086-0004-0000
- Page Start:
- 2276
- Page End:
- 2289
- Publication Date:
- 2021-05-24
- Subjects:
- accelerated MRI -- cardiac imaging -- diffusion weighted imaging -- magnetic resonance imaging -- phased array coil
Nuclear magnetic resonance -- Periodicals
Electron paramagnetic resonance -- Periodicals
616.07548 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)1522-2594 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/mrm.28843 ↗
- Languages:
- English
- ISSNs:
- 0740-3194
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5337.798000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 24019.xml