Accuracy and Reliability of the i-STAT Point-of-Care Device for the Determination of Haemoglobin Concentration before and after Major Blood Loss. Issue 4 (July 2014)
- Record Type:
- Journal Article
- Title:
- Accuracy and Reliability of the i-STAT Point-of-Care Device for the Determination of Haemoglobin Concentration before and after Major Blood Loss. Issue 4 (July 2014)
- Main Title:
- Accuracy and Reliability of the i-STAT Point-of-Care Device for the Determination of Haemoglobin Concentration before and after Major Blood Loss
- Authors:
- Ng, W. L.
Short, T. G.
Gunn, K. N.
Fuge, G. S.
Slon, B. - Abstract:
- We investigated the accuracy of i-STAT ® (Abbott Point of Care Inc., Princeton, NJ, USA) haemoglobin (Hb) measurement in surgical patients with an estimated blood loss of ≥25% of total blood volume. Blood tests for i-STAT ® Hb, laboratory Hb (Sysmex XE-2100™, Sysmex Corporation, Kobe, Japan) and total plasma proteins were obtained at the start of surgery (T=0) and when an estimated 25% total blood volume loss had occurred (T=1). Thirty-one patients were recruited. The coefficient of variation of the paired i-STAT Hb estimates was 2.8% and 2.9% at T=0 and T=1, respectively. The mean difference between i-STAT ® and laboratory Hb was −7.6 g/l (standard deviation 6.5) at T=0 and −5.1 g/l (standard deviation 12) at T=1. The mean total plasma protein difference (total plasma protein T=0 minus T=1) was 13.6 g/l (95% confidence interval 10.2 to 17.0). There was poor correlation between total plasma protein and bias in i-STAT ® measurements. The i-STAT ® Hb had an acceptable coefficient of variation, but the Hb levels were lower than those estimated by the laboratory. The standard deviation of i-STAT ® Hb was greater after ≥25% estimated total blood volume loss. Clinicians should not use the i-STAT ® Hb in isolation for clinical decision-making when considering blood transfusion in a situation of 25% or greater blood loss.
- Is Part Of:
- Anaesthesia and intensive care. Volume 42:Issue 4(2014)
- Journal:
- Anaesthesia and intensive care
- Issue:
- Volume 42:Issue 4(2014)
- Issue Display:
- Volume 42, Issue 4 (2014)
- Year:
- 2014
- Volume:
- 42
- Issue:
- 4
- Issue Sort Value:
- 2014-0042-0004-0000
- Page Start:
- 495
- Page End:
- 499
- Publication Date:
- 2014-07
- Subjects:
- haemoglobin -- measurement -- blood loss -- point-of-care
Anesthesiology -- Periodicals
Intensive Care Units -- Periodicals
617.96 - Journal URLs:
- https://journals.sagepub.com/home/aic ↗
- DOI:
- 10.1177/0310057X1404200411 ↗
- Languages:
- English
- ISSNs:
- 0310-057X
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library HMNTS - ELD Digital store
- Ingest File:
- 24012.xml