Use of tourmaline-based healthcare products and associated radiation risks. (November 2022)
- Record Type:
- Journal Article
- Title:
- Use of tourmaline-based healthcare products and associated radiation risks. (November 2022)
- Main Title:
- Use of tourmaline-based healthcare products and associated radiation risks
- Authors:
- Hassan, Halmat J.
Hashim, S.
Abu Hanifah, N.Z.H.
Sanusi, M.S.M.
Fahmi, M.R.
Tahar, R.M.
Bradley, D.A. - Abstract:
- Abstract: Investigation is made of 23 commercially available tourmaline-based healthcare products containing naturally occurring radioactive material (the products including hot spa stones, face masks, waist supporter slimming belts, arm relief belts, socks, insoles, soaps, and combs) with negative ion health benefits claimed by the purveyors. Assessment is made of the radiological risk posed by the use of such products, external exposure dose being the particular focus. Gamma spectroscopy analysis and Geant4 Monte Carlo (GMC) simulations are used. Organ doses are obtained using male and female human phantoms, dose conversion factors (DCFs) being included. For 238 U and 232t Th the tourmaline sock, code T20 was found to contain the greatest activity, at 2.4 ± 0.2 and 28.0 ± 1.3 Bq g ̶ 1 respectively; least was for the magnetic therapy face mask, code T02, at respective values 0.04 ± 0.01 and 0.1 ± 0.01 Bq g ̶ 1 . Across all of the tourmaline products, the 4 K range was 0.16 ± 0.01–16.4 ± 1.1 Bq g ̶ 1 . In terms of elemental concentration, sample T20 offered the greatest concentration, with mean percentages of 0.022 ± 0.001 and 0.78 ± 0.10, for Th and U, respectively. With the assumption of exposure for a period of 8 h per day, wearing the tourmaline sock product T20 would give rise to an annual effective dose of 0.64 mSv, less than the public annual dose limit of 1 mSv. Noting that the samples may give rise to greater doses, national screening programmes for activity areAbstract: Investigation is made of 23 commercially available tourmaline-based healthcare products containing naturally occurring radioactive material (the products including hot spa stones, face masks, waist supporter slimming belts, arm relief belts, socks, insoles, soaps, and combs) with negative ion health benefits claimed by the purveyors. Assessment is made of the radiological risk posed by the use of such products, external exposure dose being the particular focus. Gamma spectroscopy analysis and Geant4 Monte Carlo (GMC) simulations are used. Organ doses are obtained using male and female human phantoms, dose conversion factors (DCFs) being included. For 238 U and 232t Th the tourmaline sock, code T20 was found to contain the greatest activity, at 2.4 ± 0.2 and 28.0 ± 1.3 Bq g ̶ 1 respectively; least was for the magnetic therapy face mask, code T02, at respective values 0.04 ± 0.01 and 0.1 ± 0.01 Bq g ̶ 1 . Across all of the tourmaline products, the 4 K range was 0.16 ± 0.01–16.4 ± 1.1 Bq g ̶ 1 . In terms of elemental concentration, sample T20 offered the greatest concentration, with mean percentages of 0.022 ± 0.001 and 0.78 ± 0.10, for Th and U, respectively. With the assumption of exposure for a period of 8 h per day, wearing the tourmaline sock product T20 would give rise to an annual effective dose of 0.64 mSv, less than the public annual dose limit of 1 mSv. Noting that the samples may give rise to greater doses, national screening programmes for activity are suggested in seeking to mitigate unnecessary radiation exposure. Highlights: The activity level of radionuclides contain in tourmaline-based healthcare products has been evaluated using HPGe. The public effective dose from use of selected tourmaline products has been assessed using Geant4 simulation. Recommendation is made for greater control of selected products to avoid unnecessary exposure doses to the public. … (more)
- Is Part Of:
- Radiation physics and chemistry. Volume 200(2022)
- Journal:
- Radiation physics and chemistry
- Issue:
- Volume 200(2022)
- Issue Display:
- Volume 200, Issue 2022 (2022)
- Year:
- 2022
- Volume:
- 200
- Issue:
- 2022
- Issue Sort Value:
- 2022-0200-2022-0000
- Page Start:
- Page End:
- Publication Date:
- 2022-11
- Subjects:
- Consumer products -- Tourmaline -- Geant4 Monte Carlo simulation -- Radiation risk
Radiation chemistry -- Periodicals
Radiometry -- Periodicals
Radiation -- Periodicals
Chimie sous rayonnement -- Périodiques
539.2 - Journal URLs:
- http://www.sciencedirect.com/science/journal/0969806X ↗
http://www.elsevier.com/journals ↗
http://www.journals.elsevier.com/radiation-physics-and-chemistry/ ↗ - DOI:
- 10.1016/j.radphyschem.2022.110276 ↗
- Languages:
- English
- ISSNs:
- 0969-806X
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 7227.984000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 24024.xml