Preliminary evaluation of Solstice® PF as a replacement carrier solvent for Australian fingermark detection. (November 2022)
- Record Type:
- Journal Article
- Title:
- Preliminary evaluation of Solstice® PF as a replacement carrier solvent for Australian fingermark detection. (November 2022)
- Main Title:
- Preliminary evaluation of Solstice® PF as a replacement carrier solvent for Australian fingermark detection
- Authors:
- Bouzin, Jemmy T.
Frick, Amanda A.
Sauzier, Georgina
Lewis, Simon W. - Abstract:
- Abstract: HFE-7100 is a routine carrier solvent in amino acid-sensitive fingermark detection reagents such as ninhydrin and 1, 2-indanedione/zinc chloride (IND/Zn). However, a potential EU ban on hydrofluoroethers may require reformulation of these treatments worldwide. Solstice® PF has shown promise as a replacement for HFE-7100 in the United Kingdom. However, the performance (and hence optimal formulation) of IND/Zn is impacted by differences in climate and substrate composition, necessitating assessments under local conditions for different regions. We present a series of preliminary investigations in an Australian context, using the IND/Zn formulation used by Australian forensic service providers. The general performance of Solstice® PF-based IND/Zn was comparable to that using HFE-7100 on three substrate types, three ageing periods (1, 7 and 30 days) and 5 donors. However, slight differences in colour and luminescence intensity, as well as increased ink diffusion, suggest chemical interactions with other reagent components that may affect stability. Specifically, Solstice® PF-based reagent formed a precipitate within a month of storage, though this did not affect performance over a 4 month period. HFE-7100-based IND/Zn was found to be marginally more effective than Solstice® PF when applied to incidental fingermarks. These results indicate that Solstice® PF is a satisfactory alternative carrier solvent to HFE-7100 in an Australian context, though users should be awareAbstract: HFE-7100 is a routine carrier solvent in amino acid-sensitive fingermark detection reagents such as ninhydrin and 1, 2-indanedione/zinc chloride (IND/Zn). However, a potential EU ban on hydrofluoroethers may require reformulation of these treatments worldwide. Solstice® PF has shown promise as a replacement for HFE-7100 in the United Kingdom. However, the performance (and hence optimal formulation) of IND/Zn is impacted by differences in climate and substrate composition, necessitating assessments under local conditions for different regions. We present a series of preliminary investigations in an Australian context, using the IND/Zn formulation used by Australian forensic service providers. The general performance of Solstice® PF-based IND/Zn was comparable to that using HFE-7100 on three substrate types, three ageing periods (1, 7 and 30 days) and 5 donors. However, slight differences in colour and luminescence intensity, as well as increased ink diffusion, suggest chemical interactions with other reagent components that may affect stability. Specifically, Solstice® PF-based reagent formed a precipitate within a month of storage, though this did not affect performance over a 4 month period. HFE-7100-based IND/Zn was found to be marginally more effective than Solstice® PF when applied to incidental fingermarks. These results indicate that Solstice® PF is a satisfactory alternative carrier solvent to HFE-7100 in an Australian context, though users should be aware of possible limitations regarding compatibility with other evidence components (particularly inks) and shelf-life. Highlights: Alternative carrier solvent to HFE-7100 supply chain issues. Comparison of Solstice® PF and HFE-7100 in Australian IND/Zn formulation. Comparable performance, however, Solstice® PF falls short on some aspects. Solstice® PF higher polarity may cause ink diffusion. Local evaluations key to fingermark detection reagent modifications. … (more)
- Is Part Of:
- Forensic science international. Volume 340(2022)
- Journal:
- Forensic science international
- Issue:
- Volume 340(2022)
- Issue Display:
- Volume 340, Issue 2022 (2022)
- Year:
- 2022
- Volume:
- 340
- Issue:
- 2022
- Issue Sort Value:
- 2022-0340-2022-0000
- Page Start:
- Page End:
- Publication Date:
- 2022-11
- Subjects:
- Latent fingermarks -- Paper substrates -- 1, 2-indanedione -- Carrier solvents -- Supply chain issues -- Solstice® PF
Medical jurisprudence -- Periodicals
Chemistry, Forensic -- Periodicals
Forensic Medicine -- Periodicals
Médecine légale -- Périodiques
Chimie légale -- Périodiques
Gerechtelijke geneeskunde
Gerechtelijke chemie
Gerechtelijke psychiatrie
Chemistry, Forensic
Medical jurisprudence
Electronic journals
Periodicals
Electronic journals
614.1 - Journal URLs:
- http://www.clinicalkey.com.au/dura/browse/journalIssue/03790738 ↗
http://www.clinicalkey.com/dura/browse/journalIssue/03790738 ↗
http://www.sciencedirect.com/science/journal/03790738 ↗
http://infotrac.galegroup.com/itw/infomark/1/1/1/purl=rc18_EAIM_0__jn+%22Forensic+Science+International%22?sw_aep=stand ↗
http://www.elsevier.com/homepage/elecserv.htt ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.forsciint.2022.111465 ↗
- Languages:
- English
- ISSNs:
- 0379-0738
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3987.764000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 24017.xml