Remote self-collection of capillary blood using upper arm devices for autoantibody analysis in patients with immune-mediated inflammatory rheumatic diseases. Issue 2 (14th September 2022)
- Record Type:
- Journal Article
- Title:
- Remote self-collection of capillary blood using upper arm devices for autoantibody analysis in patients with immune-mediated inflammatory rheumatic diseases. Issue 2 (14th September 2022)
- Main Title:
- Remote self-collection of capillary blood using upper arm devices for autoantibody analysis in patients with immune-mediated inflammatory rheumatic diseases
- Authors:
- Zarbl, Joshua
Eimer, Ekaterina
Gigg, Camilla
Bendzuck, Gerlinde
Korinth, Marianne
Elling-Audersch, Corinna
Kleyer, Arnd
Simon, David
Boeltz, Sebastian
Krusche, Martin
Mucke, Johanna
Muehlensiepen, Felix
Vuillerme, Nicolas
Krönke, Gerhard
Schett, Georg
Knitza, Johannes - Abstract:
- Abstract : Objectives: To evaluate the feasibility, accuracy, usability and acceptability of two upper arm self-sampling devices for measurement of autoantibodies and C reactive protein (CRP) levels in patients with immune-mediated rheumatic diseases (IMRDs). Methods: 70 consecutive patients with IMRD with previously documented autoantibodies were assigned to supervised and unsupervised self-collection of capillary blood with the Tasso+ or TAP II device. Interchangeability of 17 biomarkers with standard venesection was assessed by: concordance, correlation, paired sample hypothesis testing and Bland-Altman plots. Patients completed an evaluation questionnaire, including the System Usability Scale (SUS) and Net Promoter Score (NPS). Results: While 80.0% and 77.0% were able to safely and successfully collect capillary blood using the Tasso+ and TAP II within the first attempt, 69 of 70 (98.6%) patients were successful in collecting capillary blood within two attempts. Concordance between venous and capillary samples was high; 94.7% and 99.5% for positive and negative samples, respectively. For connective tissue disease screen, anti-Ro52 and anti-proteinase 3 autoantibody levels, no significant differences were observed. Self-sampling was less painful than standard venesection for the majority of patients (Tasso+: 71%; TAP II: 63%). Both devices were well accepted (NPS; both: +28%), usability was perceived as excellent (SUS; Tasso+: 88.6 of 100; TAP II: 86.0 of 100) andAbstract : Objectives: To evaluate the feasibility, accuracy, usability and acceptability of two upper arm self-sampling devices for measurement of autoantibodies and C reactive protein (CRP) levels in patients with immune-mediated rheumatic diseases (IMRDs). Methods: 70 consecutive patients with IMRD with previously documented autoantibodies were assigned to supervised and unsupervised self-collection of capillary blood with the Tasso+ or TAP II device. Interchangeability of 17 biomarkers with standard venesection was assessed by: concordance, correlation, paired sample hypothesis testing and Bland-Altman plots. Patients completed an evaluation questionnaire, including the System Usability Scale (SUS) and Net Promoter Score (NPS). Results: While 80.0% and 77.0% were able to safely and successfully collect capillary blood using the Tasso+ and TAP II within the first attempt, 69 of 70 (98.6%) patients were successful in collecting capillary blood within two attempts. Concordance between venous and capillary samples was high; 94.7% and 99.5% for positive and negative samples, respectively. For connective tissue disease screen, anti-Ro52 and anti-proteinase 3 autoantibody levels, no significant differences were observed. Self-sampling was less painful than standard venesection for the majority of patients (Tasso+: 71%; TAP II: 63%). Both devices were well accepted (NPS; both: +28%), usability was perceived as excellent (SUS; Tasso+: 88.6 of 100; TAP II: 86.0 of 100) and 48.6 %/62.9% of patients would prefer to use the Tasso+/TAP II, respectively, instead of a traditional venous blood collection. Conclusions: Remote self-collection of capillary blood using upper arm-based devices for autoantibody and CRP analysis in patients with autoimmune rheumatic diseases is feasible, accurate and well accepted among patients. Trial registration number: WHO International Clinical Trials Registry (DRKS00024925). … (more)
- Is Part Of:
- RMD open. Volume 8:Issue 2(2022)
- Journal:
- RMD open
- Issue:
- Volume 8:Issue 2(2022)
- Issue Display:
- Volume 8, Issue 2 (2022)
- Year:
- 2022
- Volume:
- 8
- Issue:
- 2
- Issue Sort Value:
- 2022-0008-0002-0000
- Page Start:
- Page End:
- Publication Date:
- 2022-09-14
- Subjects:
- Autoimmune Diseases -- Health services research -- Antibodies, Anticardiolipin
Musculoskeletal system -- Diseases -- Periodicals
Rheumatism -- Periodicals
616.7005 - Journal URLs:
- http://www.bmj.com/archive ↗
http://rmdopen.bmj.com/ ↗ - DOI:
- 10.1136/rmdopen-2022-002641 ↗
- Languages:
- English
- ISSNs:
- 2056-5933
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 24023.xml