Repeatability of B1+ inhomogeneity correction of volumetric (3D) glutamate CEST via High‐permittivity dielectric padding at 7T. Issue 6 (15th August 2022)
- Record Type:
- Journal Article
- Title:
- Repeatability of B1+ inhomogeneity correction of volumetric (3D) glutamate CEST via High‐permittivity dielectric padding at 7T. Issue 6 (15th August 2022)
- Main Title:
- Repeatability of B1+ inhomogeneity correction of volumetric (3D) glutamate CEST via High‐permittivity dielectric padding at 7T
- Authors:
- Jacobs, Paul S.
Benyard, Blake
Cember, Abigail
Nanga, Ravi Prakash Reddy
Cao, Quy
Tisdall, M. Dylan
Wilson, Neil
Das, Sandhitsu
Davis, Kathryn A.
Detre, John
Roalf, David
Reddy, Ravinder - Abstract:
- Abstract : Purpose: Ultra‐high field MR imaging lacks B1 + inhomogeneity due to shorter RF wavelengths used at higher field strengths compared to human anatomy. CEST techniques tend to be highly susceptible to B1 + inhomogeneities due to a high and uniform B1 + field being necessary to create the endogenous contrast. High‐permittivity dielectric pads have seen increasing usage in MR imaging due to their ability to tailor the spatial distribution of the B1 + field produced. The purpose of this work is to demonstrate that dielectric materials can be used to improve glutamate weighted CEST (gluCEST) at 7T. Theory and Methods: GluCEST images were acquired on a 7T system on six healthy volunteers. Aqueous calcium titanate pads, with a permittivity of approximately 110, were placed on either side in the subject′s head near the temporal lobes. A post‐processing correction algorithm was implemented in combination with dielectric padding to compare contrast improvement. Tissue segmentation was performed to assess the effect of dielectric pads on gray and white matter separately. Results: GluCEST images demonstrated contrast enhancement in the lateral temporal lobe regions with dielectric pad placement. Tissue segmentation analysis showed an increase in correction effectiveness within the gray matter tissue compared to white matter tissue. Statistical testing suggested a significant difference in gluCEST contrast when pads were used and showed a difference in the gray matter tissueAbstract : Purpose: Ultra‐high field MR imaging lacks B1 + inhomogeneity due to shorter RF wavelengths used at higher field strengths compared to human anatomy. CEST techniques tend to be highly susceptible to B1 + inhomogeneities due to a high and uniform B1 + field being necessary to create the endogenous contrast. High‐permittivity dielectric pads have seen increasing usage in MR imaging due to their ability to tailor the spatial distribution of the B1 + field produced. The purpose of this work is to demonstrate that dielectric materials can be used to improve glutamate weighted CEST (gluCEST) at 7T. Theory and Methods: GluCEST images were acquired on a 7T system on six healthy volunteers. Aqueous calcium titanate pads, with a permittivity of approximately 110, were placed on either side in the subject′s head near the temporal lobes. A post‐processing correction algorithm was implemented in combination with dielectric padding to compare contrast improvement. Tissue segmentation was performed to assess the effect of dielectric pads on gray and white matter separately. Results: GluCEST images demonstrated contrast enhancement in the lateral temporal lobe regions with dielectric pad placement. Tissue segmentation analysis showed an increase in correction effectiveness within the gray matter tissue compared to white matter tissue. Statistical testing suggested a significant difference in gluCEST contrast when pads were used and showed a difference in the gray matter tissue segment. Conclusion: The use of dielectric pads improved the B1 + field homogeneity and enhanced gluCEST contrast for all subjects when compared to data that did not incorporate padding. … (more)
- Is Part Of:
- Magnetic resonance in medicine. Volume 88:Issue 6(2022)
- Journal:
- Magnetic resonance in medicine
- Issue:
- Volume 88:Issue 6(2022)
- Issue Display:
- Volume 88, Issue 6 (2022)
- Year:
- 2022
- Volume:
- 88
- Issue:
- 6
- Issue Sort Value:
- 2022-0088-0006-0000
- Page Start:
- 2475
- Page End:
- 2484
- Publication Date:
- 2022-08-15
- Subjects:
- CEST -- dielectric pads -- high field
Nuclear magnetic resonance -- Periodicals
Electron paramagnetic resonance -- Periodicals
616.07548 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)1522-2594 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/mrm.29409 ↗
- Languages:
- English
- ISSNs:
- 0740-3194
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5337.798000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 24001.xml