Investigating the impact of RF saturation‐pulse parameters on compartment‐selective gas‐phase depolarization with xenon polarization transfer contrast MRI. Issue 6 (31st August 2022)
- Record Type:
- Journal Article
- Title:
- Investigating the impact of RF saturation‐pulse parameters on compartment‐selective gas‐phase depolarization with xenon polarization transfer contrast MRI. Issue 6 (31st August 2022)
- Main Title:
- Investigating the impact of RF saturation‐pulse parameters on compartment‐selective gas‐phase depolarization with xenon polarization transfer contrast MRI
- Authors:
- Achekzai, Tahmina
Ruppert, Kai
Loza, Luis
Amzajerdian, Faraz
Profka, Harrilla
Duncan, Ian F.
Kadlecek, Stephen J.
Rizi, Rahim R. - Abstract:
- Abstract : Purpose: To demonstrate the utility of continuous‐wave (CW) saturation pulses in xenon‐polarization transfer contrast (XTC) MRI and MRS, to investigate the selectivity of CW pulses applied to dissolved‐phase resonances, and to develop a correction method for measurement biases from saturation of the nontargeted dissolved‐phase compartment. Methods: Studies were performed in six healthy Sprague–Dawley rats over a series of end‐exhale breath holds. Discrete saturation schemes included a series of 30 Gaussian pulses (8 ms FWHM), spaced 25 ms apart; CW saturation schemes included single block pulses, with variable flip angle and duration. In XTC imaging, saturation pulses were applied on both dissolved‐phase resonance frequencies and off‐resonance, to correct for other sources of signal loss and compromised selectivity. In spectroscopy experiments, saturation pulses were applied at a set of 19 frequencies spread out between 185 and 200 ppm to map out modified z‐spectra. Results: Both modified z‐spectra and imaging results showed that CW RF pulses offer sufficient depolarization and improved selectivity for generating contrast between presaturation and postsaturation acquisitions. A comparison of results obtained using a variety of saturation parameters confirms that saturation pulses applied at higher powers exhibit increased cross‐contamination between dissolved‐phase resonances. Conclusion: Using CW RF saturation pulses in XTC contrast preparation, with the proposedAbstract : Purpose: To demonstrate the utility of continuous‐wave (CW) saturation pulses in xenon‐polarization transfer contrast (XTC) MRI and MRS, to investigate the selectivity of CW pulses applied to dissolved‐phase resonances, and to develop a correction method for measurement biases from saturation of the nontargeted dissolved‐phase compartment. Methods: Studies were performed in six healthy Sprague–Dawley rats over a series of end‐exhale breath holds. Discrete saturation schemes included a series of 30 Gaussian pulses (8 ms FWHM), spaced 25 ms apart; CW saturation schemes included single block pulses, with variable flip angle and duration. In XTC imaging, saturation pulses were applied on both dissolved‐phase resonance frequencies and off‐resonance, to correct for other sources of signal loss and compromised selectivity. In spectroscopy experiments, saturation pulses were applied at a set of 19 frequencies spread out between 185 and 200 ppm to map out modified z‐spectra. Results: Both modified z‐spectra and imaging results showed that CW RF pulses offer sufficient depolarization and improved selectivity for generating contrast between presaturation and postsaturation acquisitions. A comparison of results obtained using a variety of saturation parameters confirms that saturation pulses applied at higher powers exhibit increased cross‐contamination between dissolved‐phase resonances. Conclusion: Using CW RF saturation pulses in XTC contrast preparation, with the proposed correction method, offers a potentially more selective alternative to traditional discrete saturation. The suppression of the red blood cell contribution to the gas‐phase depolarization opens the door to a novel way of quantifying exchange time between alveolar volume and hemoglobin. … (more)
- Is Part Of:
- Magnetic resonance in medicine. Volume 88:Issue 6(2022)
- Journal:
- Magnetic resonance in medicine
- Issue:
- Volume 88:Issue 6(2022)
- Issue Display:
- Volume 88, Issue 6 (2022)
- Year:
- 2022
- Volume:
- 88
- Issue:
- 6
- Issue Sort Value:
- 2022-0088-0006-0000
- Page Start:
- 2447
- Page End:
- 2460
- Publication Date:
- 2022-08-31
- Subjects:
- continuous‐wave (CW) pulse -- dissolved‐phase imaging -- hyperpolarized xenon‐129 -- pulmonary gas exchange
Nuclear magnetic resonance -- Periodicals
Electron paramagnetic resonance -- Periodicals
616.07548 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)1522-2594 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/mrm.29405 ↗
- Languages:
- English
- ISSNs:
- 0740-3194
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5337.798000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 24001.xml