Forward-Solution Noninvasive Computational Arrhythmia Mapping: The VMAP Study. (7th September 2022)
- Record Type:
- Journal Article
- Title:
- Forward-Solution Noninvasive Computational Arrhythmia Mapping: The VMAP Study. (7th September 2022)
- Main Title:
- Forward-Solution Noninvasive Computational Arrhythmia Mapping: The VMAP Study
- Authors:
- Krummen, David E.
Villongco, Christopher T.
Ho, Gordon
Schricker, Amir A.
Field, Michael E.
Sung, Kevin
Kacena, Katherine A.
Martinson, Melissa S.
Hoffmayer, Kurt S.
Hsu, Jonathan C.
Raissi, Farshad
Feld, Gregory K.
McCulloch, Andrew D.
Han, Frederick T. - Abstract:
- Abstract : Background: The accuracy of noninvasive arrhythmia source localization using a forward-solution computational mapping system has not yet been evaluated in blinded, multicenter analysis. This study tested the hypothesis that a computational mapping system incorporating a comprehensive arrhythmia simulation library would provide accurate localization of the site-of-origin for atrial and ventricular arrhythmias and pacing using 12-lead ECG data when compared with the gold standard of invasive electrophysiology study and ablation. Methods: The VMAP study (Vectorcardiographic Mapping of Arrhythmogenic Probability) was a blinded, multicenter evaluation with final data analysis performed by an independent core laboratory. Eligible episodes included atrial and ventricular: tachycardia, fibrillation, pacing, premature atrial and ventricular complexes, and orthodromic atrioventricular reentrant tachycardia. Mapping system results were compared with the gold standard site of successful ablation or pacing during electrophysiology study and ablation. Mapping time was assessed from time-stamped logs. Prespecified performance goals were used for statistical comparisons. Results: A total of 255 episodes from 225 patients were enrolled from 4 centers. Regional accuracy for ventricular tachycardia and premature ventricular complexes in patients without significant structural heart disease (n=75, primary end point) was 98.7% (95% CI, 96.0%–100%; P <0.001 to reject predefined H0Abstract : Background: The accuracy of noninvasive arrhythmia source localization using a forward-solution computational mapping system has not yet been evaluated in blinded, multicenter analysis. This study tested the hypothesis that a computational mapping system incorporating a comprehensive arrhythmia simulation library would provide accurate localization of the site-of-origin for atrial and ventricular arrhythmias and pacing using 12-lead ECG data when compared with the gold standard of invasive electrophysiology study and ablation. Methods: The VMAP study (Vectorcardiographic Mapping of Arrhythmogenic Probability) was a blinded, multicenter evaluation with final data analysis performed by an independent core laboratory. Eligible episodes included atrial and ventricular: tachycardia, fibrillation, pacing, premature atrial and ventricular complexes, and orthodromic atrioventricular reentrant tachycardia. Mapping system results were compared with the gold standard site of successful ablation or pacing during electrophysiology study and ablation. Mapping time was assessed from time-stamped logs. Prespecified performance goals were used for statistical comparisons. Results: A total of 255 episodes from 225 patients were enrolled from 4 centers. Regional accuracy for ventricular tachycardia and premature ventricular complexes in patients without significant structural heart disease (n=75, primary end point) was 98.7% (95% CI, 96.0%–100%; P <0.001 to reject predefined H0 <0.80). Regional accuracy for all episodes (secondary end point 1) was 96.9% (95% CI, 94.7%–99.0%; P <0.001 to reject predefined H0 <0.75). Accuracy for the exact or neighboring segment for all episodes (secondary end point 2) was 97.3% (95% CI, 95.2%–99.3%; P <0.001 to reject predefined H0 <0.70). Median spatial accuracy was 15 mm (n=255, interquartile range, 7–25 mm). The mapping process was completed in a median of 0.8 minutes (interquartile range, 0.4–1.4 minutes). Conclusions: Computational ECG mapping using a forward-solution approach exceeded prespecified accuracy goals for arrhythmia and pacing localization. Spatial accuracy analysis demonstrated clinically actionable results. This rapid, noninvasive mapping technology may facilitate catheter-based and noninvasive targeted arrhythmia therapies. Registration: URL: https://www.clinicaltrials.gov ; Unique identifier: NCT04559061. … (more)
- Is Part Of:
- Circulation. Volume 15:Number 9(2022)
- Journal:
- Circulation
- Issue:
- Volume 15:Number 9(2022)
- Issue Display:
- Volume 15, Issue 9 (2022)
- Year:
- 2022
- Volume:
- 15
- Issue:
- 9
- Issue Sort Value:
- 2022-0015-0009-0000
- Page Start:
- e010857
- Page End:
- Publication Date:
- 2022-09-07
- Subjects:
- arrhythmias, cardiac -- electrophysiology -- heart diseases -- tachycardia -- technology
Arrhythmia -- Periodicals
Heart -- Electric properties -- Periodicals
616.128 - Journal URLs:
- http://gateway.ovid.com/ovidweb.cgi?T=JS&MODE=ovid&NEWS=n&PAGE=toc&D=ovft&AN=01337493-000000000-00000 ↗
http://circep.ahajournals.org/ ↗
http://journals.lww.com ↗ - DOI:
- 10.1161/CIRCEP.122.010857 ↗
- Languages:
- English
- ISSNs:
- 1941-3149
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3265.262500
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 23977.xml