Factors leading to realignment or exchange after implantable collamer lens implantation in 10 258 eyes. Issue 10 (30th October 2022)
- Record Type:
- Journal Article
- Title:
- Factors leading to realignment or exchange after implantable collamer lens implantation in 10 258 eyes. Issue 10 (30th October 2022)
- Main Title:
- Factors leading to realignment or exchange after implantable collamer lens implantation in 10 258 eyes
- Authors:
- Wei, Ruoyan
Li, Meiyan
Aruma, Aruma
Knorz, Michael C.
Yang, Dong
Yu, Yongfu
Wang, Xiaoying
Choi, Joanne
Yao, Peijun
Zhou, Xingtao - Abstract:
- Abstract : ICL is a safe procedure with a low incidence of secondary surgery. Realignment, including vertical rotation, and exchange are practicable for the management of misalignment and excessive vault. Abstract : Purpose: To evaluate the incidence, causes, and outcomes of implantable collamer lens (ICL) realignment or exchange after implantation of the EVO-ICL. Setting: Eye and ENT Hospital of Fudan University, China. Design: Retrospective study. Methods: The study included 10 258 consecutive eyes after ICL implantation. Preoperative refractive and biometric measurements were compared between eyes with and without realignment or exchange. For eyes with ICL realignment or exchange, visual and biometric outcomes were also compared before and after ICL realignment or exchange. Results: The overall incidence of ICL realignment or exchange was 0.21% 22 eyes. 12 eyes (0.12%) underwent ICL realignment by axis rotation (10 eyes) or ICL exchange (2 eyes) due to toric ICL (TICL) misalignment. After realignment, uncorrected distance visual acuity improved, and residual cylinder decreased from −1.75 ± 0.48 diopters (D) to −0.87 ± 0.59 D ( P = .01). 10 eyes (0.10%) underwent vertical rotation of ICL (3 eyes) or ICL exchange (7 eyes) due to excessive vault. After either vertical rotation or ICL exchange, vault decreased significantly ( P < .05). Conclusions: The incidence of ICL realignment or exchange after ICL implantation is low. TICL misalignment and excessive vault are 2 mainAbstract : ICL is a safe procedure with a low incidence of secondary surgery. Realignment, including vertical rotation, and exchange are practicable for the management of misalignment and excessive vault. Abstract : Purpose: To evaluate the incidence, causes, and outcomes of implantable collamer lens (ICL) realignment or exchange after implantation of the EVO-ICL. Setting: Eye and ENT Hospital of Fudan University, China. Design: Retrospective study. Methods: The study included 10 258 consecutive eyes after ICL implantation. Preoperative refractive and biometric measurements were compared between eyes with and without realignment or exchange. For eyes with ICL realignment or exchange, visual and biometric outcomes were also compared before and after ICL realignment or exchange. Results: The overall incidence of ICL realignment or exchange was 0.21% 22 eyes. 12 eyes (0.12%) underwent ICL realignment by axis rotation (10 eyes) or ICL exchange (2 eyes) due to toric ICL (TICL) misalignment. After realignment, uncorrected distance visual acuity improved, and residual cylinder decreased from −1.75 ± 0.48 diopters (D) to −0.87 ± 0.59 D ( P = .01). 10 eyes (0.10%) underwent vertical rotation of ICL (3 eyes) or ICL exchange (7 eyes) due to excessive vault. After either vertical rotation or ICL exchange, vault decreased significantly ( P < .05). Conclusions: The incidence of ICL realignment or exchange after ICL implantation is low. TICL misalignment and excessive vault are 2 main causes. Implant exchange may be performed for excessive vault or misalignment with an insufficient vault. In addition, vertical rotation of an ICL may be a less invasive method to treat excessive vault in certain cases. … (more)
- Is Part Of:
- Journal of cataract and refractive surgery. Volume 48:Issue 10(2022)
- Journal:
- Journal of cataract and refractive surgery
- Issue:
- Volume 48:Issue 10(2022)
- Issue Display:
- Volume 48, Issue 10 (2022)
- Year:
- 2022
- Volume:
- 48
- Issue:
- 10
- Issue Sort Value:
- 2022-0048-0010-0000
- Page Start:
- 1190
- Page End:
- 1196
- Publication Date:
- 2022-10-30
- Subjects:
- 617.7
- Journal URLs:
- http://journals.lww.com/pages/default.aspx ↗
- DOI:
- 10.1097/j.jcrs.0000000000000950 ↗
- Languages:
- English
- ISSNs:
- 0886-3350
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4954.900000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 23980.xml