Understanding Noise Exposure During Cast Removal: The Effect of Cast Saw Type and Casting Material. (7th September 2022)
- Record Type:
- Journal Article
- Title:
- Understanding Noise Exposure During Cast Removal: The Effect of Cast Saw Type and Casting Material. (7th September 2022)
- Main Title:
- Understanding Noise Exposure During Cast Removal
- Authors:
- Shaw, K. Aaron
Mueller, Casey
Biolzi, Francesco
Villani, Nolan
O'Brien, Frederick
Burks, Robert - Abstract:
- Abstract : Background: Cast removal can be associated with considerable noise exposure, especially impacting the pediatric patient and provider. Although noise generation from cast saws has been deemed safe by the U.S. Occupational Safety and Health Administration and the U.S. Centers for Disease Control and Prevention standards, there are no current studies on the effects of cast material on noise levels generated. Methods: A simulated casting model utilizing plaster, fiberglass, and plaster with fiberglass overwrapping was used for experimental testing. Four different casting conditions were tested, with 5 samples in each group. Samples were tested using 2 different cast saws: a standard cast saw and a quiet saw. Each saw was used for 30 seconds of continuous cutting for each sample, measuring peak, mean, and minimum sound levels in decibels with sound level meters. Noise levels were measured at 18, 36, and 72 in (20, 91, and 183 cm) from the saw, comparing saw and cast types against ambient noise and baseline cast-saw noises. Between-group comparisons were performed using univariate analyses. Results: Mean noise generation differed between casting materials, with plaster material demonstrating significantly greater noise levels than fiberglass casts at all distances for each saw type. Increasing fiberglass thickness significantly increased the mean noise levels with standard (18-in distance for 10 and 5 ply: 87.4 and 85.8 dB; p = 0.0004) and quiet cast saws (78.3 and 76.1Abstract : Background: Cast removal can be associated with considerable noise exposure, especially impacting the pediatric patient and provider. Although noise generation from cast saws has been deemed safe by the U.S. Occupational Safety and Health Administration and the U.S. Centers for Disease Control and Prevention standards, there are no current studies on the effects of cast material on noise levels generated. Methods: A simulated casting model utilizing plaster, fiberglass, and plaster with fiberglass overwrapping was used for experimental testing. Four different casting conditions were tested, with 5 samples in each group. Samples were tested using 2 different cast saws: a standard cast saw and a quiet saw. Each saw was used for 30 seconds of continuous cutting for each sample, measuring peak, mean, and minimum sound levels in decibels with sound level meters. Noise levels were measured at 18, 36, and 72 in (20, 91, and 183 cm) from the saw, comparing saw and cast types against ambient noise and baseline cast-saw noises. Between-group comparisons were performed using univariate analyses. Results: Mean noise generation differed between casting materials, with plaster material demonstrating significantly greater noise levels than fiberglass casts at all distances for each saw type. Increasing fiberglass thickness significantly increased the mean noise levels with standard (18-in distance for 10 and 5 ply: 87.4 and 85.8 dB; p = 0.0004) and quiet cast saws (78.3 and 76.1 dB; p = 0.041. Additionally, the quiet cast saw provided a 5.7 to 10.6 dB reduction in mean and peak noise levels, varying by casting material and distance. Conclusions: Occupational noise exposure can be mitigated with the use of fiberglass casting material that is not >5 ply in thickness, with a quiet cast saw for removal. The use of a quiet cast saw substantially decreased noise exposure to patients and staff members over standard orthopaedic cast saws. … (more)
- Is Part Of:
- Journal of bone and joint surgery. Volume 104:Number 17(2022)
- Journal:
- Journal of bone and joint surgery
- Issue:
- Volume 104:Number 17(2022)
- Issue Display:
- Volume 104, Issue 17 (2022)
- Year:
- 2022
- Volume:
- 104
- Issue:
- 17
- Issue Sort Value:
- 2022-0104-0017-0000
- Page Start:
- 1573
- Page End:
- 1578
- Publication Date:
- 2022-09-07
- Subjects:
- Bones -- Surgery -- Periodicals
Joints -- Surgery -- Periodicals
Orthopedics -- Periodicals
Orthopedics
General Surgery
Bone Diseases
Joint Diseases
Bones -- Surgery
Joints -- Surgery
Orthopedics
Bot (anatomie)
Gewrichten
Chirurgie (geneeskunde)
Periodicals
Electronic journals
Periodicals
617.47005 - Journal URLs:
- http://www.clinicalkey.com/dura/browse/journalIssue/00219355 ↗
http://www.clinicalkey.com.au/dura/browse/journalIssue/00219355 ↗
http://www.ejbjs.org/contents-by-date.0.dtl ↗
http://gateway.ovid.com/ovidweb.cgi?T=JS&PAGE=toc&D=ovft&MODE=ovid&NEWS=N&AN=00002060-000000000-00000 ↗
http://journals.lww.com/pages/default.aspx ↗ - DOI:
- 10.2106/JBJS.22.00158 ↗
- Languages:
- English
- ISSNs:
- 0021-9355
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4954.250000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 23976.xml