Biomechanical Comparison of 4 Transsacral Fixation Constructs in a Type 61C, Zone II Pelvic Fracture Model. Issue 10 (October 2022)
- Record Type:
- Journal Article
- Title:
- Biomechanical Comparison of 4 Transsacral Fixation Constructs in a Type 61C, Zone II Pelvic Fracture Model. Issue 10 (October 2022)
- Main Title:
- Biomechanical Comparison of 4 Transsacral Fixation Constructs in a Type 61C, Zone II Pelvic Fracture Model
- Authors:
- Bradley, Hallie
Pierce, Bill
O'Neill, David
Jo, Chan-Hee
Ahn, Junho
Farahani, Farzam
Greif, Charlotte
Sanders, Drew
Starr, Adam - Abstract:
- Abstract : Supplemental Digital Content is Available in the Text. Abstract : Objectives: OTA/AO 61C pelvic ring injuries are vertically unstable because of complete sacral fractures combined with anterior ring injury. The objective of this study was to compare the biomechanical characteristics of 4 transsacral screw constructs for posterior pelvic ring fixation, including one that uses a novel fixation method with a pair of locked washers with interdigitating cams. Methods: Type C pelvic ring disruptions were created on 16 synthetic pelvis models. Each pelvis was fixated with an S2 screw in addition to being allocated to 1 of 4 transsacral constructs through S1: (1) 8.0-mm screw, (2) 8.0-mm bolt, (3) 8.0-mm screw locked with a nut, and (4) 8.00-mm screw locked with a nut with the addition of interdigitating washers between the screw head and ilium on the near cortex, and ilium and nut on the far cortex. The anterior ring fractures were not stabilized. Each pelvis underwent 100, 000 cycles at 250 N and was then loaded to failure using a unilateral stance testing model. The anterior and posterior osteotomy sites were instrumented with pairs of infrared (IR) light-emitting markers, and the relative displacement of the markers was monitored using a three-dimensional (3D) motion capture system. Displacement measurements at 25, 000; 50, 000; 75, 000; and 100, 000 cycles and failure force were recorded for each pelvis. Results: The novel washer design construct performed betterAbstract : Supplemental Digital Content is Available in the Text. Abstract : Objectives: OTA/AO 61C pelvic ring injuries are vertically unstable because of complete sacral fractures combined with anterior ring injury. The objective of this study was to compare the biomechanical characteristics of 4 transsacral screw constructs for posterior pelvic ring fixation, including one that uses a novel fixation method with a pair of locked washers with interdigitating cams. Methods: Type C pelvic ring disruptions were created on 16 synthetic pelvis models. Each pelvis was fixated with an S2 screw in addition to being allocated to 1 of 4 transsacral constructs through S1: (1) 8.0-mm screw, (2) 8.0-mm bolt, (3) 8.0-mm screw locked with a nut, and (4) 8.00-mm screw locked with a nut with the addition of interdigitating washers between the screw head and ilium on the near cortex, and ilium and nut on the far cortex. The anterior ring fractures were not stabilized. Each pelvis underwent 100, 000 cycles at 250 N and was then loaded to failure using a unilateral stance testing model. The anterior and posterior osteotomy sites were instrumented with pairs of infrared (IR) light-emitting markers, and the relative displacement of the markers was monitored using a three-dimensional (3D) motion capture system. Displacement measurements at 25, 000; 50, 000; 75, 000; and 100, 000 cycles and failure force were recorded for each pelvis. Results: The novel washer design construct performed better than the screw construct with less posterior ring motion at 75, 000 ( P = 0.029) and 100, 000 cycles ( P = 0.029). Conclusions: The novel interdigitating washer design may be superior to using a screw construct alone to achieve rigid, locked posterior ring fixation in a synthetic pelvis model with a Type C pelvic ring disruption. … (more)
- Is Part Of:
- Journal of orthopaedic trauma. Volume 36:Issue 10(2022)
- Journal:
- Journal of orthopaedic trauma
- Issue:
- Volume 36:Issue 10(2022)
- Issue Display:
- Volume 36, Issue 10 (2022)
- Year:
- 2022
- Volume:
- 36
- Issue:
- 10
- Issue Sort Value:
- 2022-0036-0010-0000
- Page Start:
- 503
- Page End:
- 508
- Publication Date:
- 2022-10
- Subjects:
- pelvic ring injury -- pelvis fracture -- pelvis fixation
Orthopedics -- Periodicals
Wounds and injuries -- Periodicals
Orthopedics -- Periodicals
Wounds and Injuries -- therapy -- Periodicals
Periodicals
617.47044 - Journal URLs:
- http://journals.lww.com/jorthotrauma/pages/default.aspx ↗
http://www.jorthotrauma.com ↗
http://cufts2.lib.sfu.ca/CJDB/BVAS/journal/149202 ↗
http://gateway.ovid.com/ovidweb.cgi?T=JS&MODE=ovid&PAGE=toc&D=ovft&AN=00005131-000000000-00000 ↗
http://journals.lww.com ↗ - DOI:
- 10.1097/BOT.0000000000002381 ↗
- Languages:
- English
- ISSNs:
- 0890-5339
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5027.675000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 23984.xml