A New Contact Lens Sensor System for Continuous Intraocular Pressure Monitoring: Evaluation of Safety and Tolerability. Issue 10 (12th October 2022)
- Record Type:
- Journal Article
- Title:
- A New Contact Lens Sensor System for Continuous Intraocular Pressure Monitoring: Evaluation of Safety and Tolerability. Issue 10 (12th October 2022)
- Main Title:
- A New Contact Lens Sensor System for Continuous Intraocular Pressure Monitoring: Evaluation of Safety and Tolerability
- Authors:
- Zhang, Yuning
Wei, Yifan
Karunaratne, I. K.
Lee, Ching Hymn Christopher
Deng, Mingjie
Chen, Zidong
Yang, Yangfan
Chong, Iok Tong
Lam, David C. C.
Yu, Minbin - Abstract:
- Abstract : Purpose: To assess the safety and tolerability of a new contact lens sensor (CLS) system for continuous 3- and 24-hr intraocular pressure (IOP) monitoring in human eyes. Methods: Twenty-five subjects were recruited for 3-hr IOP measurement by CLS. Corneal fluorescein staining (CFS) scores were evaluated before and after measurement. Then, 30 participants (10 normal subjects and 20 glaucoma patients) were recruited for 24-hr IOP monitoring. Ocular surface disease index (OSDI) was assessed before and one day after measurement. Contact lens dry eye questionnaire-8 was assessed immediately after measurement. Visual analog scale of discomfort was measured before, immediately after, and one day after measurement. Best-corrected visual acuity (BCVA), tear break-up time (TBUT), and CFS were assessed before, immediately after, and 1 day after measurement. Results: All participants completed 3- or 24-hr IOP measurement by CLS. Corneal fluorescein staining increased from 0.6±0.7 to 2.4±1.5 after 3-hr IOP measurement ( P <0.001). For participants undergoing 24-hr IOP monitoring, OSDI increased from 9.1±9.7 to 18.0±12.4 ( P =0.001). CLDEQ-8 score was 11.6±5.8. Visual analog scale increased from 11.1±14.2 to 35.2±21.8 after measurement ( P <0.001) and decreased to 26.7±18.4 one day later ( P <0.001 compared with baseline). BCVA decreased from 1.0±0.01 to 0.8±0.1 ( P <0.001) and returned to 0.9±0.1 after one day ( P <0.001 compared with baseline). TBUT decreased from 5.1±3.9 toAbstract : Purpose: To assess the safety and tolerability of a new contact lens sensor (CLS) system for continuous 3- and 24-hr intraocular pressure (IOP) monitoring in human eyes. Methods: Twenty-five subjects were recruited for 3-hr IOP measurement by CLS. Corneal fluorescein staining (CFS) scores were evaluated before and after measurement. Then, 30 participants (10 normal subjects and 20 glaucoma patients) were recruited for 24-hr IOP monitoring. Ocular surface disease index (OSDI) was assessed before and one day after measurement. Contact lens dry eye questionnaire-8 was assessed immediately after measurement. Visual analog scale of discomfort was measured before, immediately after, and one day after measurement. Best-corrected visual acuity (BCVA), tear break-up time (TBUT), and CFS were assessed before, immediately after, and 1 day after measurement. Results: All participants completed 3- or 24-hr IOP measurement by CLS. Corneal fluorescein staining increased from 0.6±0.7 to 2.4±1.5 after 3-hr IOP measurement ( P <0.001). For participants undergoing 24-hr IOP monitoring, OSDI increased from 9.1±9.7 to 18.0±12.4 ( P =0.001). CLDEQ-8 score was 11.6±5.8. Visual analog scale increased from 11.1±14.2 to 35.2±21.8 after measurement ( P <0.001) and decreased to 26.7±18.4 one day later ( P <0.001 compared with baseline). BCVA decreased from 1.0±0.01 to 0.8±0.1 ( P <0.001) and returned to 0.9±0.1 after one day ( P <0.001 compared with baseline). TBUT decreased from 5.1±3.9 to 2.6±1.5 s ( P =0.001) and returned to 4.8±2.5 s ( P =0.465 compared with baseline). Corneal fluorescein staining increased from 0.7±0.9 to 4.3±0.8 ( P <0.001) and dropped to 0.8±0.7 ( P =0.599 compared with baseline). No significant difference was found for all variations of indicators between normal subjects and glaucoma patients ( P >0.1 for all comparisons). Conclusions: The CLS shows a great potential for a safe and tolerable 24-hr IOP monitoring in normal subjects and glaucoma patients. Clinical attention to the worsening signs and symptoms after measurement is required. … (more)
- Is Part Of:
- Eye & contact lens. Volume 48:Issue 10(2022)
- Journal:
- Eye & contact lens
- Issue:
- Volume 48:Issue 10(2022)
- Issue Display:
- Volume 48, Issue 10 (2022)
- Year:
- 2022
- Volume:
- 48
- Issue:
- 10
- Issue Sort Value:
- 2022-0048-0010-0000
- Page Start:
- 439
- Page End:
- 444
- Publication Date:
- 2022-10-12
- Subjects:
- 24-hour intraocular pressure -- Contact lens -- Safety -- Tolerability
Contact lenses -- Periodicals
Intraocular lenses -- Periodicals
Orthokeratology -- Periodicals
Anterior segment (Eye) -- Diseases -- Periodicals
617.7523 - Journal URLs:
- http://journals.lww.com/claojournal/pages/default.aspx ↗
http://journals.lww.com ↗ - DOI:
- 10.1097/ICL.0000000000000926 ↗
- Languages:
- English
- ISSNs:
- 1542-2321
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3854.587000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 23982.xml