Fabrication and characterization of a multimodal 3D printed mouse phantom for ionoacoustic quality assurance in image-guided pre-clinical proton radiation research. (21st October 2022)
- Record Type:
- Journal Article
- Title:
- Fabrication and characterization of a multimodal 3D printed mouse phantom for ionoacoustic quality assurance in image-guided pre-clinical proton radiation research. (21st October 2022)
- Main Title:
- Fabrication and characterization of a multimodal 3D printed mouse phantom for ionoacoustic quality assurance in image-guided pre-clinical proton radiation research
- Authors:
- Lascaud, Julie
Dash, Pratik
Schnürle, Katrin
Bortfeldt, Jonathan
Niepel, Katharina
Maas, Jessica
Würl, Matthias
Vidal, Marie
Hérault, Joël
Landry, Guillaume
Savoia, Alessandro Stuart
Lauber, Kirsten
Parodi, Katia - Abstract:
- Abstract: Objective. Image guidance and precise irradiation are fundamental to ensure the reliability of small animal oncology studies. Accurate positioning of the animal and the in-beam monitoring of the delivered radio-therapeutic treatment necessitate several imaging modalities. In the particular context of proton therapy with a pulsed beam, information on the delivered dose can be retrieved by monitoring the thermoacoustic waves resulting from the brief and local energy deposition induced by a proton beam (ionoacoustics). The objective of this work was to fabricate a multimodal phantom (x-ray, proton, ultrasound, and ionoacoustics) allowing for sufficient imaging contrast for all the modalities. Approach. The phantom anatomical parts were extracted from mouse computed tomography scans and printed using polylactic acid (organs) and a granite/polylactic acid composite (skeleton). The anatomical pieces were encapsulated in silicone rubber to ensure long term stability. The phantom was imaged using x-ray cone-beam computed tomography, proton radiography, ultrasound imaging, and monitoring of a 20 MeV pulsed proton beam using ionoacoustics. Main results. The anatomical parts could be visualized in all the imaging modalities validating the phantom capability to be used for multimodal imaging. Ultrasound images were simulated from the x-ray cone-beam computed tomography and co-registered with ultrasound images obtained before the phantom irradiation and low-resolutionAbstract: Objective. Image guidance and precise irradiation are fundamental to ensure the reliability of small animal oncology studies. Accurate positioning of the animal and the in-beam monitoring of the delivered radio-therapeutic treatment necessitate several imaging modalities. In the particular context of proton therapy with a pulsed beam, information on the delivered dose can be retrieved by monitoring the thermoacoustic waves resulting from the brief and local energy deposition induced by a proton beam (ionoacoustics). The objective of this work was to fabricate a multimodal phantom (x-ray, proton, ultrasound, and ionoacoustics) allowing for sufficient imaging contrast for all the modalities. Approach. The phantom anatomical parts were extracted from mouse computed tomography scans and printed using polylactic acid (organs) and a granite/polylactic acid composite (skeleton). The anatomical pieces were encapsulated in silicone rubber to ensure long term stability. The phantom was imaged using x-ray cone-beam computed tomography, proton radiography, ultrasound imaging, and monitoring of a 20 MeV pulsed proton beam using ionoacoustics. Main results. The anatomical parts could be visualized in all the imaging modalities validating the phantom capability to be used for multimodal imaging. Ultrasound images were simulated from the x-ray cone-beam computed tomography and co-registered with ultrasound images obtained before the phantom irradiation and low-resolution ultrasound images of the mouse phantom in the irradiation position, co-registered with ionoacoustic measurements. The latter confirmed the irradiation of a tumor surrogate for which the reconstructed range was found to be in reasonable agreement with the expectation. Significance. This study reports on a realistic small animal phantom which can be used to investigate ionoacoustic range (or dose) verification together with ultrasound, x-ray, and proton imaging. The co-registration between ionoacoustic reconstructions of the impinging proton beam and x-ray imaging is assessed for the first time in a pre-clinical scenario. … (more)
- Is Part Of:
- Physics in medicine & biology. Volume 67:Number 20(2022)
- Journal:
- Physics in medicine & biology
- Issue:
- Volume 67:Number 20(2022)
- Issue Display:
- Volume 67, Issue 20 (2022)
- Year:
- 2022
- Volume:
- 67
- Issue:
- 20
- Issue Sort Value:
- 2022-0067-0020-0000
- Page Start:
- Page End:
- Publication Date:
- 2022-10-21
- Subjects:
- proton therapy -- range verification -- small animal -- phantom -- ionoacoustics
Biophysics -- Periodicals
Medical physics -- Periodicals
610.153 - Journal URLs:
- http://ioppublishing.org/ ↗
http://iopscience.iop.org/0031-9155 ↗ - DOI:
- 10.1088/1361-6560/ac9031 ↗
- Languages:
- English
- ISSNs:
- 0031-9155
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 23976.xml