Computer software (SiD) assisted real-time single sperm selection associated with fertilization and blastocyst formation. Issue 4 (October 2022)
- Record Type:
- Journal Article
- Title:
- Computer software (SiD) assisted real-time single sperm selection associated with fertilization and blastocyst formation. Issue 4 (October 2022)
- Main Title:
- Computer software (SiD) assisted real-time single sperm selection associated with fertilization and blastocyst formation
- Authors:
- Mendizabal-Ruiz, Gerardo
Chavez-Badiola, Alejandro
Aguilar Figueroa, Isaac
Martinez Nuño, Vladimir
Flores-Saiffe Farias, Adolfo
Valencia-Murilloa, Roberto
Drakeley, Andrew
Garcia-Sandoval, Juan Paulo
Cohen, Jacques - Abstract:
- Abstract: Research question: Is it possible to explore an association between individual sperm kinematics evaluated in real time and spermatozoa selected by an embryologist for intracytoplasmic sperm injection (ICSI), with subsequent normal fertilization and blastocyst formation using a novel artificial vision-based software (SiD V1.0; IVF 2.0, UK)? Design: ICSI procedures were randomly video recorded and subjected to analysis using SiD V1.0, proprietary software developed by our group. In total, 383 individual spermatozoa were retrospectively analysed from a dataset of 78 ICSI-assisted reproductive technology cycles. SiD software computes the progressive motility parameters, straight-line velocity (VSL) and linearity of the curvilinear path (LIN), of each sperm trajectory, along with a quantitative value, head movement pattern (HMP), which is an indicator of the characteristics of the sperm head movement patterns. The mean VSL, LIN and HMP measurements for each set of spermatozoa were compared based on different outcome measures. Results: Statistically significant differences were found in VSL, LIN and HMP among those spermatozoa selected for injection ( P < 0.001). Additionally, LIN and HMP were found to be significantly different between successful and unsuccessful fertilization ( P = 0.038 and P = 0.029, respectively). Additionally, significantly higher SiD scores were found for those spermatozoa that achieved both successful fertilization ( P = 0.004) and blastocystAbstract: Research question: Is it possible to explore an association between individual sperm kinematics evaluated in real time and spermatozoa selected by an embryologist for intracytoplasmic sperm injection (ICSI), with subsequent normal fertilization and blastocyst formation using a novel artificial vision-based software (SiD V1.0; IVF 2.0, UK)? Design: ICSI procedures were randomly video recorded and subjected to analysis using SiD V1.0, proprietary software developed by our group. In total, 383 individual spermatozoa were retrospectively analysed from a dataset of 78 ICSI-assisted reproductive technology cycles. SiD software computes the progressive motility parameters, straight-line velocity (VSL) and linearity of the curvilinear path (LIN), of each sperm trajectory, along with a quantitative value, head movement pattern (HMP), which is an indicator of the characteristics of the sperm head movement patterns. The mean VSL, LIN and HMP measurements for each set of spermatozoa were compared based on different outcome measures. Results: Statistically significant differences were found in VSL, LIN and HMP among those spermatozoa selected for injection ( P < 0.001). Additionally, LIN and HMP were found to be significantly different between successful and unsuccessful fertilization ( P = 0.038 and P = 0.029, respectively). Additionally, significantly higher SiD scores were found for those spermatozoa that achieved both successful fertilization ( P = 0.004) and blastocyst formation ( P = 0.013). Conclusion: The possibility of carrying out real-time analyses of individual spermatozoa using an automatic tool such as SiD creates the opportunity to assist the embryologist in selecting the better spermatozoon for injection in an ICSI procedure. … (more)
- Is Part Of:
- Reproductive biomedicine online. Volume 45:Issue 4(2022)
- Journal:
- Reproductive biomedicine online
- Issue:
- Volume 45:Issue 4(2022)
- Issue Display:
- Volume 45, Issue 4 (2022)
- Year:
- 2022
- Volume:
- 45
- Issue:
- 4
- Issue Sort Value:
- 2022-0045-0004-0000
- Page Start:
- 703
- Page End:
- 711
- Publication Date:
- 2022-10
- Subjects:
- AI-ICSI -- AI sperm selection assistant -- Artificial-vision assisted ICSI -- Male factor -- Sperm head movement patterns
Human reproductive technology -- Periodicals
Human embryo -- Periodicals
Reproduction -- Periodicals
616.692 - Journal URLs:
- http://www.rbmonline.com/ ↗
http://www.sciencedirect.com/science/journal/14726483 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.rbmo.2022.03.036 ↗
- Languages:
- English
- ISSNs:
- 1472-6483
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 7713.705600
British Library DSC - BLDSS-3PM
British Library STI - Digital store
British Library STI - ELD Digital store - Ingest File:
- 23980.xml