Improving methodology to determine vitamin D3 in food supplements. (1st April 2021)
- Record Type:
- Journal Article
- Title:
- Improving methodology to determine vitamin D3 in food supplements. (1st April 2021)
- Main Title:
- Improving methodology to determine vitamin D3 in food supplements
- Authors:
- Ferreira, Carla
Figueiredo, Alexandra
Moutinho, Guilhermina
Auxtero, Maria D.
Costa, Isabel Margarida
Quintas, Alexandre - Abstract:
- Abstract: Introduction: Nowadays, there is a trend to enrich food and food supplements (FS) with Vitamin D3 . Economic operators who places FS on the market does not have to perform running safety trials, but only to comply with the food safety regulations applicable in the European Union [1 ]. This scenario may present public health and legal issues. To overcome these challenges, it is mandatory to know accurately the amount of vitamin D3 in FS and if it corresponds to the label value. HPLC methods are a preferential approach to determine accurately the content of vitamin D3 in pharmaceuticals and supplements. Actually, HPLC/MS has become the technique of choice for vitamin D3 determination in complex matrixes. Notwithstanding, this analysis must be preceded by time-consuming sample preparation. In fact, the success to measure accurately vitamin D3 depends heavily in a reliable sample preparation. Moreover, it becomes even more critic when dealing with different formulations of vitamin D3, such has gel pills, solid pills, liquid or cutaneous applications. There are literature validating methodology to determinate vitamin D3 in various matrixes according to the International Conference on Harmonisation (ICH) guidelines by HPLC-UV [2 ]. However, this published study does not use an internal standard (IS). The internal standard is useful to improve the precision of quantitative analysis, removing the error of losing sample during sample preparation. Our aim is to test o-cresolAbstract: Introduction: Nowadays, there is a trend to enrich food and food supplements (FS) with Vitamin D3 . Economic operators who places FS on the market does not have to perform running safety trials, but only to comply with the food safety regulations applicable in the European Union [1 ]. This scenario may present public health and legal issues. To overcome these challenges, it is mandatory to know accurately the amount of vitamin D3 in FS and if it corresponds to the label value. HPLC methods are a preferential approach to determine accurately the content of vitamin D3 in pharmaceuticals and supplements. Actually, HPLC/MS has become the technique of choice for vitamin D3 determination in complex matrixes. Notwithstanding, this analysis must be preceded by time-consuming sample preparation. In fact, the success to measure accurately vitamin D3 depends heavily in a reliable sample preparation. Moreover, it becomes even more critic when dealing with different formulations of vitamin D3, such has gel pills, solid pills, liquid or cutaneous applications. There are literature validating methodology to determinate vitamin D3 in various matrixes according to the International Conference on Harmonisation (ICH) guidelines by HPLC-UV [2 ]. However, this published study does not use an internal standard (IS). The internal standard is useful to improve the precision of quantitative analysis, removing the error of losing sample during sample preparation. Our aim is to test o-cresol as an internal standard to future validation the methodology. Materials and methods: Vit D3 present in FS was analysed by HPLC/DAD. Sample was spiked with internal standard ( o -cresol) and liquid extraction coupled to an ultrasound bath was used has an extraction procedure. After a centrifuged step the supernatant was filtered. The separation was performed using a C18 column with a solvent gradient consisted in (A) 0.1% formic acid and (B) acetonitrile. The acquisition was performed on DAD-detector at 265 nm. Results: Figure 1 shows a chromatogram of a FS containing Vit D3 . Two major peaks are present, corresponding to o -cresol (RT 5.45 min) and Vit D3 (RT 11.20 min). Discussion and conclusions: The results show the capacity of the chromatographic method to separate and resolve the two chromatographic peaks. These preliminary results show that o-cresol can be used as an internal standard to determine Vit D3 in FS, normalising the loss of Vit D3 during preparation step. Since in Europe and USA, the association of vitD toxicity with the use of FS has been described, this methodology will be useful to confirm the VitD composition stated on the label. … (more)
- Is Part Of:
- Annals of medicine. Volume 53:Supplement 1(2021)
- Journal:
- Annals of medicine
- Issue:
- Volume 53:Supplement 1(2021)
- Issue Display:
- Volume 53, Issue 1 (2021)
- Year:
- 2021
- Volume:
- 53
- Issue:
- 1
- Issue Sort Value:
- 2021-0053-0001-0000
- Page Start:
- S78
- Page End:
- S78
- Publication Date:
- 2021-04-01
- Subjects:
- Medicine -- Periodicals
610 - Journal URLs:
- http://informahealthcare.com/loi/ann ↗
http://www.tandf.co.uk/journals/titles/07853890.asp ↗
http://informahealthcare.com ↗ - DOI:
- 10.1080/07853890.2021.1897427 ↗
- Languages:
- English
- ISSNs:
- 0785-3890
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 1043.131000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 23987.xml