Validation of Trace Element Analysis of Geological Materials by Single-Pulse Laser Ablation-Inductively Coupled Plasma-Mass Spectrometry (LA-ICP-MS). (20th September 2022)
- Record Type:
- Journal Article
- Title:
- Validation of Trace Element Analysis of Geological Materials by Single-Pulse Laser Ablation-Inductively Coupled Plasma-Mass Spectrometry (LA-ICP-MS). (20th September 2022)
- Main Title:
- Validation of Trace Element Analysis of Geological Materials by Single-Pulse Laser Ablation-Inductively Coupled Plasma-Mass Spectrometry (LA-ICP-MS)
- Authors:
- Sagawa, Takuya
Tamura, Akihiro
Okino, Kyoko
Morishita, Tomoaki - Abstract:
- Abstract: Laser ablation–inductively coupled plasma – mass spectrometry (LA–ICP–MS) is a powerful tool for determining the elemental and isotopic compositions of various samples. The disadvantage of LA–ICP–MS is that it consumes more sample material than other types of in situ analytical methods. To extend the application of this method to trace element analysis, we conducted single-pulse LA–ICP–MS analysis of the Reference Materials of the National Institute of Standards and Technology (SRM 610, 612, and 614) and the United States Geological Survey (BCR-2G, BHVO-2G, and BIR-1G). The accuracy of the determined concentrations and the precision of the single-pulse LA–ICP–MS analysis were verified by comparison with recommended concentrations for these standards and those obtained by conventional analysis with the same system. Time-resolved profiles of the analyzed elements in the glass samples show that the background-corrected intensity reaches a peak immediately after the start of the laser pulse and then gradually decreases. During each analysis, the isotope ratios are stable until the background-corrected intensity of the elements reaches 5% of the peak values. The relative standard deviation of the single-pulse LA–ICP–MS analyses is significantly higher than for conventional LA–ICP–MS analysis. However, most of the determined concentrations obtained from the reference materials except for NIST SRM614, NIST SRM612, BCR-2G, and BHVO-2G mostly agreed with the recommendedAbstract: Laser ablation–inductively coupled plasma – mass spectrometry (LA–ICP–MS) is a powerful tool for determining the elemental and isotopic compositions of various samples. The disadvantage of LA–ICP–MS is that it consumes more sample material than other types of in situ analytical methods. To extend the application of this method to trace element analysis, we conducted single-pulse LA–ICP–MS analysis of the Reference Materials of the National Institute of Standards and Technology (SRM 610, 612, and 614) and the United States Geological Survey (BCR-2G, BHVO-2G, and BIR-1G). The accuracy of the determined concentrations and the precision of the single-pulse LA–ICP–MS analysis were verified by comparison with recommended concentrations for these standards and those obtained by conventional analysis with the same system. Time-resolved profiles of the analyzed elements in the glass samples show that the background-corrected intensity reaches a peak immediately after the start of the laser pulse and then gradually decreases. During each analysis, the isotope ratios are stable until the background-corrected intensity of the elements reaches 5% of the peak values. The relative standard deviation of the single-pulse LA–ICP–MS analyses is significantly higher than for conventional LA–ICP–MS analysis. However, most of the determined concentrations obtained from the reference materials except for NIST SRM614, NIST SRM612, BCR-2G, and BHVO-2G mostly agreed with the recommended values within 20%. In addition, the geochemical features of basaltic reference glasses were accurately reproduced by the single-pulse LA–ICP–MS analyses. In conclusion, the single-pulse LA–ICP–MS method provides usable results for the determination of multiple trace elements in geological materials. … (more)
- Is Part Of:
- Analytical letters. Volume 55:Number 18(2022)
- Journal:
- Analytical letters
- Issue:
- Volume 55:Number 18(2022)
- Issue Display:
- Volume 55, Issue 18 (2022)
- Year:
- 2022
- Volume:
- 55
- Issue:
- 18
- Issue Sort Value:
- 2022-0055-0018-0000
- Page Start:
- 2886
- Page End:
- 2896
- Publication Date:
- 2022-09-20
- Subjects:
- Laser ablation–inductively coupled plasma–mass spectrometry (LA-ICP-MS) -- single-pulse laser sampling -- geological materials -- trace element analysis
Chemistry, Analytic -- Periodicals
Chemistry, Analytic -- Abstracts
543 - Journal URLs:
- http://www.tandfonline.com/toc/lanl20/current ↗
http://taylorandfrancis.metapress.com/link.asp?id=107818, ↗
http://www.tandfonline.com/ ↗ - DOI:
- 10.1080/00032719.2022.2077356 ↗
- Languages:
- English
- ISSNs:
- 0003-2719
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 0897.100000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 23975.xml