Analysis of the critical temperature on load bearing LSF walls under fire. (1st November 2022)
- Record Type:
- Journal Article
- Title:
- Analysis of the critical temperature on load bearing LSF walls under fire. (1st November 2022)
- Main Title:
- Analysis of the critical temperature on load bearing LSF walls under fire
- Authors:
- Piloto, Paulo A.G.
Khetata, Mohamed S.
Ramos-Gavilán, Ana B. - Abstract:
- Highlights: Nine (9) experimental fire tests were developed on a reduced scale LSF wall to determine the insulation fire resistance. Validation of the thermal model using the reduced scale experiments. Validation of the thermal model and the mechanical model using the full scale experiments developed by other researchers. Parametric analysis to determine the fire resistance (R) and (I) for the reduced and full scale LSF walls. New proposal to determine the relationship between the critical temperature of the LSF and the load level. Abstract: Light Steel Frame (LSF) walls are widely used in building structures, used as partition walls and load bearing walls. The LSF is usually protected by layers of homogeneous plates or composite plates, with or without insulation materials in the cavity. This investigation presents the simulation results of composite LSF walls in reduced scale and full scale, based on variable load levels (20 to 80%). The numerical model uses a hybrid model approximation, based on the experimental tests to accurately determine the temperature field. The numerical model is validated with experimental results, at reduced and full scale, both at room temperature and under fire conditions. This modelling technique can follow the thermal and mechanical degradation of the protection layers of the LSF wall and determine the fire rating for load bearing (R) and insulation (I). The fire resistance (R) decreases with the increase of the load level. The insulationHighlights: Nine (9) experimental fire tests were developed on a reduced scale LSF wall to determine the insulation fire resistance. Validation of the thermal model using the reduced scale experiments. Validation of the thermal model and the mechanical model using the full scale experiments developed by other researchers. Parametric analysis to determine the fire resistance (R) and (I) for the reduced and full scale LSF walls. New proposal to determine the relationship between the critical temperature of the LSF and the load level. Abstract: Light Steel Frame (LSF) walls are widely used in building structures, used as partition walls and load bearing walls. The LSF is usually protected by layers of homogeneous plates or composite plates, with or without insulation materials in the cavity. This investigation presents the simulation results of composite LSF walls in reduced scale and full scale, based on variable load levels (20 to 80%). The numerical model uses a hybrid model approximation, based on the experimental tests to accurately determine the temperature field. The numerical model is validated with experimental results, at reduced and full scale, both at room temperature and under fire conditions. This modelling technique can follow the thermal and mechanical degradation of the protection layers of the LSF wall and determine the fire rating for load bearing (R) and insulation (I). The fire resistance (R) decreases with the increase of the load level. The insulation ability is also predicted for different protection materials. Relevant conclusions are presented to increase the insulation ability of LSF walls, especially when using non combustible double protection layers. The insulation ability to sustain fire usually increases with the number of studs and with the application of insulation material in the cavity region. The ability to sustain the load under fire also increases with the number of studs, especially for higher load levels. The ability to sustain the load also increases with the number of protection layers, changing from 16% at 20% load level, to 42% at 50% load level. A new proposal is presented for the critical temperature of the LSF, based on the maximum temperature of the LSF during the fire, allowing the calculation of the critical temperature, based on the load level of the specimen. This relation can predict the fire resistance time, based on the preliminary thermal analysis of the specimen. The reduced scale specimens present higher critical temperatures when compared to the full scale specimens, due to the typical failure mode (local modes for the reduced scale and global modes for the large scale). … (more)
- Is Part Of:
- Engineering structures. Volume 270(2022)
- Journal:
- Engineering structures
- Issue:
- Volume 270(2022)
- Issue Display:
- Volume 270, Issue 2022 (2022)
- Year:
- 2022
- Volume:
- 270
- Issue:
- 2022
- Issue Sort Value:
- 2022-0270-2022-0000
- Page Start:
- Page End:
- Publication Date:
- 2022-11-01
- Subjects:
- LSF walls -- Fire resistance -- Numerical validation -- Standard fire tests
Structural engineering -- Periodicals
Structural analysis (Engineering) -- Periodicals
Construction, Technique de la -- Périodiques
Génie parasismique -- Périodiques
Pression du vent -- Périodiques
Earthquake engineering
Structural engineering
Wind-pressure
Periodicals
624.105 - Journal URLs:
- http://www.sciencedirect.com/science/journal/01410296 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.engstruct.2022.114858 ↗
- Languages:
- English
- ISSNs:
- 0141-0296
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3770.032000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 23969.xml