Performance of 3D diamond detectors in small field dosimetry: The impact of pixel size. (October 2022)
- Record Type:
- Journal Article
- Title:
- Performance of 3D diamond detectors in small field dosimetry: The impact of pixel size. (October 2022)
- Main Title:
- Performance of 3D diamond detectors in small field dosimetry: The impact of pixel size
- Authors:
- Kanxheri, Keida
Talamonti, Cinzia
Sciortino, Silvio
Lagomarsino, Stefano
Ionica, Maria
Caprai, Mirco
Moscatelli, Francesco
Servoli, Leonello - Abstract:
- Abstract: Purpose: Small photon beams used in radiotherapy techniques have inherent characteristics of charge particle disequilibrium and high-dose gradient making accurate dosimetry for such fields very challenging. By means of a 3D manufacturing technique, it is possible to create arrays of pixels with a very small sensitive volume for radiotherapy dosimetry. We investigate the impact of 3D pixels size on absorbed dose sensitivity, linearity of response with dose rate, reproducibility and beam profile measurements. Methods: Diamond detectors with different pixel sizes have been produced in the 3DOSE experiment framework. To investigate the pixels size impact, they were tested using an Elekta Synergy LINAC. Dose rate dependence, absorbed dose sensitivity, reproducibility and beam profile measurement accuracy have been investigated and compared with PTW 60019 and IBA SFD reference dosimeters. Results: All of the 3D pixels had a linear and reproducible response to the dose rate. The sensitivity of a pixel decreases with its size, although even the smallest pixel has a high absorbed dose sensitivity (15 nC/Gy). The penumbra width measured with the smallest pixel size was consistent with the PTW microDiamond and differed by 0.2 mm from the IBA SFD diode. Conclusions: The study demonstrates that variation in pixel size do not affect the linearity of response with dose rate and the reproducibility of response. Due to the 3D geometry, the absorbed dose sensitivity of the detectorAbstract: Purpose: Small photon beams used in radiotherapy techniques have inherent characteristics of charge particle disequilibrium and high-dose gradient making accurate dosimetry for such fields very challenging. By means of a 3D manufacturing technique, it is possible to create arrays of pixels with a very small sensitive volume for radiotherapy dosimetry. We investigate the impact of 3D pixels size on absorbed dose sensitivity, linearity of response with dose rate, reproducibility and beam profile measurements. Methods: Diamond detectors with different pixel sizes have been produced in the 3DOSE experiment framework. To investigate the pixels size impact, they were tested using an Elekta Synergy LINAC. Dose rate dependence, absorbed dose sensitivity, reproducibility and beam profile measurement accuracy have been investigated and compared with PTW 60019 and IBA SFD reference dosimeters. Results: All of the 3D pixels had a linear and reproducible response to the dose rate. The sensitivity of a pixel decreases with its size, although even the smallest pixel has a high absorbed dose sensitivity (15 nC/Gy). The penumbra width measured with the smallest pixel size was consistent with the PTW microDiamond and differed by 0.2 mm from the IBA SFD diode. Conclusions: The study demonstrates that variation in pixel size do not affect the linearity of response with dose rate and the reproducibility of response. Due to the 3D geometry, the absorbed dose sensitivity of the detector remains high even for the smallest pixel, furthermore the pixel size was demonstrated to be of fundamental importance in the measurement of beam profiles. Highlights: Highly segmented pcCVD diamond detectors are fabricated using a pulsed laser grafitization technique. All size pixels have dose rate linearity, repeatability and response homogeneity. Small beam profile measurements with 3D detectors depend on the pixel size. Small pixel beam profiles are in good agreement with PTW microDiamond and IBA SFD silicon diode. … (more)
- Is Part Of:
- Physica medica. Volume 102(2022)
- Journal:
- Physica medica
- Issue:
- Volume 102(2022)
- Issue Display:
- Volume 102, Issue 2022 (2022)
- Year:
- 2022
- Volume:
- 102
- Issue:
- 2022
- Issue Sort Value:
- 2022-0102-2022-0000
- Page Start:
- 73
- Page End:
- 78
- Publication Date:
- 2022-10
- Subjects:
- 3D polycrystalline diamond detectors -- Graphitic electrodes -- Pixel size -- Radiotherapy concepts
Medical physics -- Periodicals
Biophysics -- Periodicals
Biophysics -- Periodicals
Imagerie médicale -- Périodiques
Radiothérapie -- Périodiques
Rayons X -- Sécurité -- Mesures -- Périodiques
Physique -- Périodiques
Médecine -- Périodiques
610.153 - Journal URLs:
- http://www.sciencedirect.com/science/journal/11201797 ↗
http://www.clinicalkey.com/dura/browse/journalIssue/11201797 ↗
http://www.clinicalkey.com.au/dura/browse/journalIssue/11201797 ↗
http://www.elsevier.com/journals ↗
http://www.physicamedica.com ↗ - DOI:
- 10.1016/j.ejmp.2022.09.006 ↗
- Languages:
- English
- ISSNs:
- 1120-1797
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 6475.070000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 23962.xml