Development of a High-Performance Anesthesia Ventilator for Research in Small Animals. Issue 6 (June 2014)
- Record Type:
- Journal Article
- Title:
- Development of a High-Performance Anesthesia Ventilator for Research in Small Animals. Issue 6 (June 2014)
- Main Title:
- Development of a High-Performance Anesthesia Ventilator for Research in Small Animals
- Authors:
- Popoiu, Calin Marius
Burian, Caius Alexandru
Paunescu, Virgil
Boia, Eugen
Arghirescu, Smaranda
Muntean, Danina Mirela
Ordodi, Valentin Laurentiu - Abstract:
- Introduction: Small animal models are used extensively in basic research because of their low cost and possibility to mimic several human pathologies. These models are used to either analyze the underlying mechanisms and/or assess therapeutic approaches. In this respect, gentle and safe artificial ventilation is mandatory, especially for prolonged experimental procedures that require the survival of the animals. The aim of the present paper was to develop and validate a high-performance anesthesia ventilator for small animals. Methods: A pressure-controlled ventilator with assisted ventilation and deep breath modulated on a scheduled basis and a PEEP facility for an improved anesthetic management was developed. Parameters of acid-base balance and arterial blood gases were measured initially at the end of arterial catheterization and monitored throughout the experiment. Results: Our data show the following average values (mmHg) for pO2 : 440 +/- 45 (initial), 378 +/- 24 (2 h), 373 +/- 22 (4 h), and 375 +/- 28 (6 h) and for pCO2 : 35 +/- 3 (initial), 34 +/- 5 (2 h), 38 +/- 5 (4 h), and 40 +/- 6 (6 h), respectively. Conclusions: We describe the procedure for the manufacture of a reliable, high-performance anesthesia ventilator that facilitates recovery of spontaneous respiration at animal arousal with preservation of normal blood gases values and no damage to the lungs.
- Is Part Of:
- International journal of artificial organs. Volume 37:Issue 6(2014)
- Journal:
- International journal of artificial organs
- Issue:
- Volume 37:Issue 6(2014)
- Issue Display:
- Volume 37, Issue 6 (2014)
- Year:
- 2014
- Volume:
- 37
- Issue:
- 6
- Issue Sort Value:
- 2014-0037-0006-0000
- Page Start:
- 436
- Page End:
- 441
- Publication Date:
- 2014-06
- Subjects:
- Pressure-controlled ventilator -- Spontaneous respiration -- Rat surgery -- Anesthesia
Artificial organs -- Periodicals
617.956 - Journal URLs:
- http://catalog.hathitrust.org/api/volumes/oclc/3676874.html ↗
http://www.artificial-organs.com/ ↗
http://www.wichtig-publisher.com/jao/ ↗
http://www.uk.sagepub.com/home.nav ↗
http://journals.sagepub.com/loi/jaoa ↗
https://us.sagepub.com/en-us/nam/the-international-journal-of-artificial-organs/journal203459 ↗ - DOI:
- 10.5301/ijao.5000330 ↗
- Languages:
- English
- ISSNs:
- 0391-3988
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 23964.xml