Anatomic accuracy of airway training manikins compared with humans. (27th August 2020)
- Record Type:
- Journal Article
- Title:
- Anatomic accuracy of airway training manikins compared with humans. (27th August 2020)
- Main Title:
- Anatomic accuracy of airway training manikins compared with humans
- Authors:
- Blackburn, M. B.
Wang, S. C.
Ross, B. E.
Holcombe, S. A.
Kempski, K. M.
Blackburn, A. N.
DeLorenzo, R. A.
Ryan, K. L. - Abstract:
- Summary: Airway simulators, or training manikins, are frequently used in research studies for device development and training purposes. This study was designed to determine the anatomic accuracy of the most frequently used low‐fidelity airway training manikins. Computerised tomography scans and ruler measurements were taken of the SynDaver ®, Laerdal ® and AirSim ® manikins. These measurements were compared with human computerised tomography (CT) scans (n = 33) from patients at the University of Michigan Medical Center or previously published values. Manikin measurements were scored as a percentile among the distribution of the same measurements in the human population and 10 out of 27 manikin measurements (nine measurements each in three manikins) were outside of two standard deviations from the mean in the participants. All three manikins were visually identifiable as outliers when plotting the first two dimensions from multidimensional scaling. In particular, the airway space between the epiglottis and posterior pharyngeal wall, through which airway devices must pass, was too large in all three manikins. SynDaver, Laerdal and AirSim manikins do not have anatomically correct static dimensions in relation to humans and these inaccuracies may lead to imprecise airway device development, negatively affect training and cause over‐confidence in users.
- Is Part Of:
- Anaesthesia. Volume 76:Number 3(2021)
- Journal:
- Anaesthesia
- Issue:
- Volume 76:Number 3(2021)
- Issue Display:
- Volume 76, Issue 3 (2021)
- Year:
- 2021
- Volume:
- 76
- Issue:
- 3
- Issue Sort Value:
- 2021-0076-0003-0000
- Page Start:
- 366
- Page End:
- 372
- Publication Date:
- 2020-08-27
- Subjects:
- airway -- anatomic accuracy -- manikin -- trainers
Anesthesia -- Periodicals
617.96 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1111/(ISSN)1365-2044 ↗
http://onlinelibrary.wiley.com/ ↗
http://www.aagbi.org/publications ↗ - DOI:
- 10.1111/anae.15238 ↗
- Languages:
- English
- ISSNs:
- 0003-2409
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 0859.900000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 23955.xml