Bilateral regional extracranial blood flow regulation to hypoxia and unilateral duplex ultrasound measurement error. Issue 7 (14th May 2021)
- Record Type:
- Journal Article
- Title:
- Bilateral regional extracranial blood flow regulation to hypoxia and unilateral duplex ultrasound measurement error. Issue 7 (14th May 2021)
- Main Title:
- Bilateral regional extracranial blood flow regulation to hypoxia and unilateral duplex ultrasound measurement error
- Authors:
- Friend, Alexander T.
Rogan, Matthew.
Rossetti, Gabriella M. K.
Lawley, Justin S.
Mullins, Paul G.
Sandoo, Aamer
Macdonald, Jamie H.
Oliver, Samuel J. - Abstract:
- Abstract : New Findings: What is the central question of this study? Is blood flow regulation to hypoxia different between the internal carotid arteries (ICAs) and vertebral arteries (VAs), and what is the measurement error in unilateral extracranial artery assessments compared to bilateral? What is the main finding and its importance? ICA and VA blood flow regulation to hypoxia is comparable when factoring for vessel type and vessel side. Compared to bilateral assessment, vessels assessed unilaterally had individual measurement errors of up to 37%. Assessing the vessel with the larger resting blood flow, not the left or right vessel, reduces unilateral measurement error. Abstract: Whether blood flow regulation to hypoxia is similar between left and right internal carotid arteries (ICAs) and vertebral arteries (VAs) is unclear. Extracranial blood flow is regularly calculated by doubling a unilateral assessment; however, lateral artery differences may lead to measurement error. This study aimed to determine extracranial blood flow regulation to hypoxia when factoring for vessel type (ICAs or VAs) and vessel side (left or right) effects, and to investigate unilateral assessment measurement error compared to bilateral assessment. In a repeated‐measures crossover design, extracranial arteries of 44 participants were assessed bilaterally by duplex ultrasound during 90 min of normoxic and poikilocapnic hypoxic (12.0% fraction of inspired oxygen) conditions. Linear mixed modelAbstract : New Findings: What is the central question of this study? Is blood flow regulation to hypoxia different between the internal carotid arteries (ICAs) and vertebral arteries (VAs), and what is the measurement error in unilateral extracranial artery assessments compared to bilateral? What is the main finding and its importance? ICA and VA blood flow regulation to hypoxia is comparable when factoring for vessel type and vessel side. Compared to bilateral assessment, vessels assessed unilaterally had individual measurement errors of up to 37%. Assessing the vessel with the larger resting blood flow, not the left or right vessel, reduces unilateral measurement error. Abstract: Whether blood flow regulation to hypoxia is similar between left and right internal carotid arteries (ICAs) and vertebral arteries (VAs) is unclear. Extracranial blood flow is regularly calculated by doubling a unilateral assessment; however, lateral artery differences may lead to measurement error. This study aimed to determine extracranial blood flow regulation to hypoxia when factoring for vessel type (ICAs or VAs) and vessel side (left or right) effects, and to investigate unilateral assessment measurement error compared to bilateral assessment. In a repeated‐measures crossover design, extracranial arteries of 44 participants were assessed bilaterally by duplex ultrasound during 90 min of normoxic and poikilocapnic hypoxic (12.0% fraction of inspired oxygen) conditions. Linear mixed model analyses revealed no Condition × Vessel Type × Vessel Side interaction for blood flow, vessel diameter and flow velocity (all P > 0.05) indicating left and right ICA and VA blood flow regulation to hypoxia was similar. Bilateral hypoxic reactivity was comparable (ICAs, 1.4 (1.0) vs. VAs, 1.7 (1.1) Δ%·Δ S p O 2 −1 ; P = 0.12). Compared to bilateral assessment, unilateral mean measurement error of the relative blood flow response to hypoxia was up to 5%, but individual errors reached 37% and were greatest in ICAs and VAs with the smaller resting blood flow due to a ratio‐scaling problem. In conclusion, left and right ICA and VA regulation to hypoxia is comparable when factoring for vessel type and vessel side. Assessing the ICA and VA vessels with the larger resting blood flow, not the left or right vessel, reduces unilateral measurement error. Abstract : … (more)
- Is Part Of:
- Experimental physiology. Volume 106:Issue 7(2021)
- Journal:
- Experimental physiology
- Issue:
- Volume 106:Issue 7(2021)
- Issue Display:
- Volume 106, Issue 7 (2021)
- Year:
- 2021
- Volume:
- 106
- Issue:
- 7
- Issue Sort Value:
- 2021-0106-0007-0000
- Page Start:
- 1535
- Page End:
- 1548
- Publication Date:
- 2021-05-14
- Subjects:
- bias -- cerebrovascular -- doppler -- hypoxia -- internal carotid artery -- ultrasonography -- vertebral artery
Physiology, Experimental -- Periodicals
571.0724 - Journal URLs:
- http://physoc.onlinelibrary.wiley.com/hub/journal/10.1111/(ISSN)1469-445X/issues/ ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1113/EP089196 ↗
- Languages:
- English
- ISSNs:
- 0958-0670
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3840.040000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 23939.xml