Asymmetric susceptibility tensor imaging. Issue 4 (20th May 2021)
- Record Type:
- Journal Article
- Title:
- Asymmetric susceptibility tensor imaging. Issue 4 (20th May 2021)
- Main Title:
- Asymmetric susceptibility tensor imaging
- Authors:
- Cao, Steven
Wei, Hongjiang
Chen, Jingjia
Liu, Chunlei - Abstract:
- Abstract : Purpose: To investigate the symmetry constraint in susceptibility tensor imaging. Theory: The linear relationship between the MRI frequency shift and the magnetic susceptibility tensor is derived without constraining the tensor to be symmetric. In the asymmetric case, the system matrix is shown to be maximally rank 6. Nonetheless, relaxing the symmetry constraint may still improve tensor estimation because noise and image artifacts do not necessarily follow the constraint. Methods: Gradient echo phase data are obtained from postmortem mouse brain and kidney samples. Both symmetric and asymmetric tensor reconstructions are applied to the data. The reconstructions are then used for susceptibility tensor imaging fiber tracking. Simulations with ground truth and at various noise levels are also performed. The reconstruction methods are compared qualitatively and quantitatively. Results: Compared to regularized and unregularized symmetric reconstructions, the asymmetric reconstruction shows reduced noise and streaking artifacts, better contrast, and more complete fiber tracking. In simulation, the asymmetric reconstruction achieves better mean squared error and better angular difference in the presence of noise. Decomposing the asymmetric tensor into its symmetric and antisymmetric components confirms that the underlying susceptibility tensor is symmetric and that the main sources of asymmetry are noise and streaking artifacts. Conclusion: Whereas the susceptibilityAbstract : Purpose: To investigate the symmetry constraint in susceptibility tensor imaging. Theory: The linear relationship between the MRI frequency shift and the magnetic susceptibility tensor is derived without constraining the tensor to be symmetric. In the asymmetric case, the system matrix is shown to be maximally rank 6. Nonetheless, relaxing the symmetry constraint may still improve tensor estimation because noise and image artifacts do not necessarily follow the constraint. Methods: Gradient echo phase data are obtained from postmortem mouse brain and kidney samples. Both symmetric and asymmetric tensor reconstructions are applied to the data. The reconstructions are then used for susceptibility tensor imaging fiber tracking. Simulations with ground truth and at various noise levels are also performed. The reconstruction methods are compared qualitatively and quantitatively. Results: Compared to regularized and unregularized symmetric reconstructions, the asymmetric reconstruction shows reduced noise and streaking artifacts, better contrast, and more complete fiber tracking. In simulation, the asymmetric reconstruction achieves better mean squared error and better angular difference in the presence of noise. Decomposing the asymmetric tensor into its symmetric and antisymmetric components confirms that the underlying susceptibility tensor is symmetric and that the main sources of asymmetry are noise and streaking artifacts. Conclusion: Whereas the susceptibility tensor is symmetric, asymmetric reconstruction is more effective in suppressing noise and artifacts, resulting in more accurate estimation of the susceptibility tensor. … (more)
- Is Part Of:
- Magnetic resonance in medicine. Volume 86:Issue 4(2021)
- Journal:
- Magnetic resonance in medicine
- Issue:
- Volume 86:Issue 4(2021)
- Issue Display:
- Volume 86, Issue 4 (2021)
- Year:
- 2021
- Volume:
- 86
- Issue:
- 4
- Issue Sort Value:
- 2021-0086-0004-0000
- Page Start:
- 2266
- Page End:
- 2275
- Publication Date:
- 2021-05-20
- Subjects:
- asymmetric susceptibility tensor -- image reconstruction -- streaking artifacts -- susceptibility tensor imaging
Nuclear magnetic resonance -- Periodicals
Electron paramagnetic resonance -- Periodicals
616.07548 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)1522-2594 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/mrm.28823 ↗
- Languages:
- English
- ISSNs:
- 0740-3194
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5337.798000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 23944.xml