Characterization and correction of cardiovascular motion artifacts in diffusion‐weighted imaging of the pancreas. Issue 4 (17th June 2021)
- Record Type:
- Journal Article
- Title:
- Characterization and correction of cardiovascular motion artifacts in diffusion‐weighted imaging of the pancreas. Issue 4 (17th June 2021)
- Main Title:
- Characterization and correction of cardiovascular motion artifacts in diffusion‐weighted imaging of the pancreas
- Authors:
- Geng, Ruiqi
Zhang, Yuxin
Starekova, Jitka
Rutkowski, David R.
Estkowski, Lloyd
Roldán‐Alzate, Alejandro
Hernando, Diego - Abstract:
- Abstract : Purpose: To assess the effects of cardiovascular‐induced motion on conventional DWI of the pancreas and to evaluate motion‐robust DWI methods in a motion phantom and healthy volunteers. Methods: 3T DWI was acquired using standard monopolar and motion‐compensated gradient waveforms, including in an anatomically accurate pancreas phantom with controllable compressive motion and healthy volunteers ( n = 8, 10). In volunteers, highly controlled single‐slice DWI using breath‐holding and cardiac gating and whole‐pancreas respiratory‐triggered DWI were acquired. For each acquisition, the ADC variability across volunteers, as well as ADC differences across parts of the pancreas were evaluated. Results: In motion phantom scans, conventional DWI led to biased ADC, whereas motion‐compensated waveforms produced consistent ADC. In the breath‐held, cardiac‐triggered study, conventional DWI led to heterogeneous DW signals and highly variable ADC across the pancreas, whereas motion‐compensated DWI avoided these artifacts. In the respiratory‐triggered study, conventional DWI produced heterogeneous ADC across the pancreas (head: 1756 ± 173 × 10 −6 mm 2 /s; body: 1530 ± 338 × 10 −6 mm 2 /s; tail: 1388 ± 267 × 10 −6 mm 2 /s), with ADCs in the head significantly higher than in the tail ( P < .05). Motion‐compensated ADC had lower variability across volunteers (head: 1277 ± 102 × 10 −6 mm 2 /s; body: 1204 ± 169 × 10 −6 mm 2 /s; tail: 1235 ± 178 × 10 −6 mm 2 /s), with no significantAbstract : Purpose: To assess the effects of cardiovascular‐induced motion on conventional DWI of the pancreas and to evaluate motion‐robust DWI methods in a motion phantom and healthy volunteers. Methods: 3T DWI was acquired using standard monopolar and motion‐compensated gradient waveforms, including in an anatomically accurate pancreas phantom with controllable compressive motion and healthy volunteers ( n = 8, 10). In volunteers, highly controlled single‐slice DWI using breath‐holding and cardiac gating and whole‐pancreas respiratory‐triggered DWI were acquired. For each acquisition, the ADC variability across volunteers, as well as ADC differences across parts of the pancreas were evaluated. Results: In motion phantom scans, conventional DWI led to biased ADC, whereas motion‐compensated waveforms produced consistent ADC. In the breath‐held, cardiac‐triggered study, conventional DWI led to heterogeneous DW signals and highly variable ADC across the pancreas, whereas motion‐compensated DWI avoided these artifacts. In the respiratory‐triggered study, conventional DWI produced heterogeneous ADC across the pancreas (head: 1756 ± 173 × 10 −6 mm 2 /s; body: 1530 ± 338 × 10 −6 mm 2 /s; tail: 1388 ± 267 × 10 −6 mm 2 /s), with ADCs in the head significantly higher than in the tail ( P < .05). Motion‐compensated ADC had lower variability across volunteers (head: 1277 ± 102 × 10 −6 mm 2 /s; body: 1204 ± 169 × 10 −6 mm 2 /s; tail: 1235 ± 178 × 10 −6 mm 2 /s), with no significant difference ( P ≥ .19) across the pancreas. Conclusion: Cardiovascular motion introduces artifacts and ADC bias in pancreas DWI, which are addressed by motion‐robust DWI. … (more)
- Is Part Of:
- Magnetic resonance in medicine. Volume 86:Issue 4(2021)
- Journal:
- Magnetic resonance in medicine
- Issue:
- Volume 86:Issue 4(2021)
- Issue Display:
- Volume 86, Issue 4 (2021)
- Year:
- 2021
- Volume:
- 86
- Issue:
- 4
- Issue Sort Value:
- 2021-0086-0004-0000
- Page Start:
- 1956
- Page End:
- 1969
- Publication Date:
- 2021-06-17
- Subjects:
- cardiovascular compression -- compressive motion -- diffusion‐weighted imaging -- DWI artifacts -- pancreas
Nuclear magnetic resonance -- Periodicals
Electron paramagnetic resonance -- Periodicals
616.07548 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)1522-2594 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/mrm.28846 ↗
- Languages:
- English
- ISSNs:
- 0740-3194
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5337.798000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 23944.xml