Validating three-dimensional imaging for volumetric assessment of periorbital soft tissue. (2nd January 2021)
- Record Type:
- Journal Article
- Title:
- Validating three-dimensional imaging for volumetric assessment of periorbital soft tissue. (2nd January 2021)
- Main Title:
- Validating three-dimensional imaging for volumetric assessment of periorbital soft tissue
- Authors:
- Hyer, Jonathan N.
Murta, Fabiola
Juniat, Valerie A. R.
Ezra, Daniel G. - Abstract:
- ABSTRACT: Purpose : To evaluate the accuracy and interobserver variability of three-dimensional (3D) stereophotogrammetric imaging for volumetric assessment in the periorbital region and to propose a protocol for measurement. Methods : A cross-sectional study was performed. Fifty-eight normal adult subjects had photographs taken using the VECTRA M3 imaging system on two separate occasions at a single center teaching hospital. The primary study outcome measurement was mean volume change in the periorbital region, using different methods of image analysis with the following variables: registration method, eyes open or closed, eyelids measured separately or together, extension of area measured to include mid-face. Accuracy was defined as the agreement between paired images with no measured change in volume (0 mL). The agreement between two independent observers was assessed using Bland–Altman plots. Results : There was a statistically significant difference ( P < .0001) between the different methods of measurement, with registration of images having the most effect (partial eta squared 0.229). A mean change in volume of 0.11 ± 0.13 mL was reported for the most accurate method. Agreement between observers was confirmed (highest Intraclass Correlation Coefficient 0.63). Conclusions : Assessment of volumetric change in the periorbital region using 3D image reconstruction is accurate with good interobserver repeatability and is suitable for clinical use. A protocol for dataABSTRACT: Purpose : To evaluate the accuracy and interobserver variability of three-dimensional (3D) stereophotogrammetric imaging for volumetric assessment in the periorbital region and to propose a protocol for measurement. Methods : A cross-sectional study was performed. Fifty-eight normal adult subjects had photographs taken using the VECTRA M3 imaging system on two separate occasions at a single center teaching hospital. The primary study outcome measurement was mean volume change in the periorbital region, using different methods of image analysis with the following variables: registration method, eyes open or closed, eyelids measured separately or together, extension of area measured to include mid-face. Accuracy was defined as the agreement between paired images with no measured change in volume (0 mL). The agreement between two independent observers was assessed using Bland–Altman plots. Results : There was a statistically significant difference ( P < .0001) between the different methods of measurement, with registration of images having the most effect (partial eta squared 0.229). A mean change in volume of 0.11 ± 0.13 mL was reported for the most accurate method. Agreement between observers was confirmed (highest Intraclass Correlation Coefficient 0.63). Conclusions : Assessment of volumetric change in the periorbital region using 3D image reconstruction is accurate with good interobserver repeatability and is suitable for clinical use. A protocol for data acquisition using the VECTRA M3 is proposed. 3D image reconstruction holds promise to enable diagnosis, treatment monitoring, and surgical outcome evaluation in ocular adnexal disease. … (more)
- Is Part Of:
- Orbit. Volume 40:Number 1(2021)
- Journal:
- Orbit
- Issue:
- Volume 40:Number 1(2021)
- Issue Display:
- Volume 40, Issue 1 (2021)
- Year:
- 2021
- Volume:
- 40
- Issue:
- 1
- Issue Sort Value:
- 2021-0040-0001-0000
- Page Start:
- 9
- Page End:
- 17
- Publication Date:
- 2021-01-02
- Subjects:
- 3D imaging -- 3D stereo photogrammetry -- Orbital soft tissue -- Vectra -- Volume
Eye-sockets -- Surgery -- Periodicals
Eye-sockets -- Diseases -- Periodicals
Orbit -- surgery -- Periodicals
Orbital Diseases -- Periodicals
617.7 - Journal URLs:
- http://informahealthcare.com/loi/orb ↗
http://informahealthcare.com ↗
http://www.tandf.co.uk/journals/titles/01676830.asp ↗ - DOI:
- 10.1080/01676830.2020.1711780 ↗
- Languages:
- English
- ISSNs:
- 0167-6830
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 6277.869600
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 23932.xml